0102U025 - Plan Set - signed.pdf
PDF 28 MB Posted
- Solicitation number
- 25-50
- Issued by
- Atlantic County, New Jersey
About this file
The documents are structural and electrical engineering plan sets for the Fisherman's Park Pump Station Upgrades project, prepared by Remington & Vernick Engineers for the City of Atlantic City, Atlantic County, New Jersey. The project involves comprehensive upgrades to the existing pump station, including installation of a new bar screen, transformer pad, and associated electrical infrastructure. Key components include a 10'x14'-10" bar screen with stainless steel components, a transformer pad designed to support a 15,000-pound transformer, and electrical system modifications. The project is funded through an Economic Development Administration (EDA) grant, with project number ED24PHI0G0302, and includes structural modifications to existing culvert walls and infrastructure.
The engineering plans detail precise technical specifications, including the use of Type 316 stainless steel for structural framing, anchor bolts, and miscellaneous metal components. The transformer pad will be supported by 25-ton concrete-filled steel pipe piles driven 81 feet below existing grade, with an 8-inch thick structural slab and specific reinforcement requirements. Electrical system upgrades include a new single-line diagram, site plan modifications, and demolition of existing electrical infrastructure. The project appears to be part of a broader municipal infrastructure improvement initiative, with careful attention to structural integrity, materials selection, and compliance with current building codes and engineering standards.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Tech Specs.pdf | ||
| BID 25-50 Fishermans Park Pump Upgrades.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
( IN FEET )
GRAPHIC SCALE
1 inch = ft.
20 20
S-1
BA
R
SC
R
EE
N
D
EM
O
LI
TI
O
N P
LA
N
A N
D S
EC
TI
O N
S
SHEET No. :
CHECKED BY :DRAWN BY : DESIGN BY :
JOB No. :
DATE :
SCALE :
JG CK/AK JDT
N o.
C H
K R
EV
IS
IO
N
D
AT
E
BY
P:
\C
AD
D
P ro je ct s\ N
J\ At la nt ic C o\ At la nt ic C ty C ty \0
2U
- B al tic A ve D ra in ag e
C an al B ar S cr ee n\
U
5-
St ru ct ur al D ra w in gs
Ba r S cr ee n.
dw g
/2
1/
:3 4:
P
M
ALL DOCUMENTS PREPARED BY REMINGTON & VERNICK
ENGINEERS AND AFFILIATES ARE INSTRUMENTS OF
SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT
INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE
BY OWNER OR OTHERS ON EXTENSIONS OF THE PROJECT
OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT
WRITTEN VERIFICATION OR ADAPTATION BY REMINGTON &
VERNICK ENGINEERS AND AFFILIATES FOR THE SPECIFIC
PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND
WITHOUT LIABILITY OR LEGAL EXPOSURE TO REMINGTON
& VERNICK ENGINEERS AND AFFILIATES; AND OWNER
SHALL INDEMNIFY AND HOLD HARMLESS REMINGTON &
VERNICK ENGINEERS AND AFFILIATES FROM ALL CLAIMS,
DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR
R E S U L T I N G T H E R E F R O M .
P L A N S W H I C H D O N O T B E A R A N E M B O S S E D S E A L A R E N O T V A L I D .
NJ PROFESSIONAL ENGINEER LIC. No. 51944
JACQUELINE D. TROVATO
DATE:
(609) 645-7110, FAX (609) 645-7076
2819 FIRE ROAD, 1ST FLOOR
EGG HARBOR TOWNSHIP, NJ 08234
REMINGTON
& VERNICK
ENGINEERS
Certification of Authorization: 24 GA 28003300
WEB ADDRESS : RVE.COM
· Excellence Innovation Service·
4.21.2025
0102U025
AS NOTED
C
IT
Y O
F
AT
LA
N
TI
C
C
IT
Y D
EP
AR
TM
EN
T O
F
PU
BL
IC
W O
R
KS
C
IT
Y O
F
AT
LA
N
TI
C
C
IT
Y
AT
LA
N
TI
C
C O
U N
TY
N
EW
J
ER
SE
Y
FI
SH
ER
M
AN
'S
P
AR
K
PU
M P
ST
AT
IO
N
U
PG
R
AD
ES
AutoCAD SHX Text
TOP OF CULVERT ELEV. 2.30' ±
AutoCAD SHX Text
TOP OF FOOTING ELEV. -9.70' ±
AutoCAD SHX Text
TOP OF CULVERT TO BE REMOVED
AutoCAD SHX Text
GENERATOR
AutoCAD SHX Text
ELECTRICAL CONTROL ROOM
AutoCAD SHX Text A
AutoCAD SHX Text S-1
AutoCAD SHX Text
TOP OF CULVERT TO BE REMOVED
AutoCAD SHX Text 04-21-2025
AutoCAD SHX Text
SUPERSTRUCTURE CONCRETE
AutoCAD SHX Text
MISCELLANEOUS
AutoCAD SHX Text
DESIGN CRITERIA
AutoCAD SHX Text
%%UGENERAL NOTES
AutoCAD SHX Text
1. CONTRACTOR SHALL VERIFY CONDITIONS IN THE FIELD AND CONTRACTOR SHALL VERIFY CONDITIONS IN THE FIELD AND IMMEDIATELY NOTIFY ENGINEER OF ANY CONDITIONS NOT AS ASSUMED; HE SHALL TAKE FIELD MEASUREMENTS AS REQUIRED AND BE RESPONSIBLE FOR SAME. . 2. CONTRACTOR SHALL COORDINATE WITH ALL RELATED TRADES FOR CONTRACTOR SHALL COORDINATE WITH ALL RELATED TRADES FOR DETAILING, FABRICATION, AND ERECTION PRIOR TO SUBMITTING SHOP DRAWINGS FOR APPROVAL. . 3. ALL STRUCTURAL WORK SHALL BE COORDINATED WITH ALL STRUCTURAL WORK SHALL BE COORDINATED WITH ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING, ETC. REQUIREMENTS. DISCREPANCIES AND/OR INTERFERENCE SHALL BE REPORTED TO THE ENGINEER IMMEDIATELY. . 4. GENERAL CONTRACTOR TO PROVIDE APPROPRIATE NUMBER OF GENERAL CONTRACTOR TO PROVIDE APPROPRIATE NUMBER OF COPIES OF ONE COMPLETE COORDINATED DRAWING SHOWING ALL SLEEVES, CONDUIT BOXOUT, DUCT OPENINGS, ETC. AS REQUIRED FOR ALL TRADES FOR ENGINEER'S APPROVAL. THIS SHALL BE DONE A MINIMUM OF TWO WEEKS PRIOR TO POURING AFFECTED SLABS, COLUMNS, OR FOOTINGS. . 5. NO OPENINGS SHALL BE MADE IN ANY STRUCTURAL MEMBER NO OPENINGS SHALL BE MADE IN ANY STRUCTURAL MEMBER UNLESS SPECIFICALLY SHOWN ON THE STRUCTURAL DRAWINGS OR OTHER APPROVAL FROM THE ENGINEER. . 6. SUPPORT DETAILS FOR ARCHITECTURAL, MECHANICAL, ELECTRICAL, SUPPORT DETAILS FOR ARCHITECTURAL, MECHANICAL, ELECTRICAL, AND PLUMBING EQUIPMENT IS BASED UPON AVAILABLE INFORMATION OF MANUFACTURER. CONTRACTOR SHALL COORDINATE REQUIREMENTS OF ACTUAL EQUIPMENT AND SHALL PROVIDE ANY ADDITIONAL REQUIRED FRAMING..
AutoCAD SHX Text
1. ALL CONCRETE SHALL BE NORMAL WEIGHT STRUCTURAL CONCRETE ALL CONCRETE SHALL BE NORMAL WEIGHT STRUCTURAL CONCRETE HAVING A DESIGN COMPRESSIVE STRENGTH AS FOLLOWS: A. COLUMNS 4,000 PSI COLUMNS 4,000 PSI 4,000 PSI B. SLABS, BEAM 4,000 PSI SLABS, BEAM 4,000 PSI 4,000 PSI C. WALLS 4,000 PSI WALLS 4,000 PSI 4,000 PSI 2. NO CONCRETE SHALL BE PLACED UNTIL CONCRETE DESIGN MIXES NO CONCRETE SHALL BE PLACED UNTIL CONCRETE DESIGN MIXES HAVE BEEN SUBMITTED FOR EACH CLASS OF CONCRETE NOTED ABOVE AND HAVE BEEN APPROVED BY THE ENGINEER. . 3. REINFORCING STEEL SHALL BE DEFORMED BARS OF INTERMEDIATE REINFORCING STEEL SHALL BE DEFORMED BARS OF INTERMEDIATE GRADE NEW BILLET STEEL CONFORMING TO CURRENT REQUIREMENTS OF ASTM A 615, GRADE 60. LAP BARS 40 DIAMETER UNLESS OTHERWISE SHOWN. ALL HOOKS SHALL BE STANDARD HOOKS, UNLESS OTHERWISE NOTED. . 4. MINIMUM STEEL PROTECTION, UNLESS OTHERWISE SHOWN, SHALL BE MINIMUM STEEL PROTECTION, UNLESS OTHERWISE SHOWN, SHALL BE 3/4-INCH FOR SLABS, 1-INCH FOR INTERIOR FACE OF WALLS, 2-INCH FOR EXTERIOR FACE OF WALLS, 1 1/2-INCH FOR BEAM STIRRUPS AND COLUMN TIES, 2-INCH FOR VERTICAL COLUMN REINFORCING. . 5. ALL STRUCTURAL MEMBERS SHALL BE POURED FOR THEIR FULL ALL STRUCTURAL MEMBERS SHALL BE POURED FOR THEIR FULL DEPTHS IN ONE OPERATION. CONSTRUCTION JOINTS, SUCH AS DAY'S POUR JOINTS, SHALL BE LOCATED IN THE MIDDLE THIRD OF THE SPAN, MAIN REINFORCING TO RUN THROUGH THE JOINT, KEY AND ROUGHEN JOINTS TO EXPOSE AGGREGATE. CONTRACTOR SHALL SUBMIT DRAWING INDICATING CONSTRUCTION JOINT LOCATIONS FOR APPROVAL. . 6. NO OPENINGS SHALL BE MADE IN ANY STRUCTURAL MEMBER, NO OPENINGS SHALL BE MADE IN ANY STRUCTURAL MEMBER, UNLESS SPECIFICALLY SHOWN ON THE STRUCTURAL DRAWINGS, WITHOUT APPROVAL FROM THE ENGINEER. NO SLEEVES SHALL BE PLACED HORIZONTALLY OR VERTICALLY IN BEAMS OR JOISTS, UNLESS SPECIFICALLY SHOWN ON THE STRUCTURAL DRAWINGS, WITHOUT APPROVAL FROM THE ENGINEER. . 7. CONTRACTOR SHALL SUBMIT A COORDINATED DRAWING SHOWING CONTRACTOR SHALL SUBMIT A COORDINATED DRAWING SHOWING ALL SLEEVES, OPENINGS, BLOCKOUTS, ETC., AS REQUIRED BY ALL TRADES, FOR APPROVAL, PRIOR TO PLACING CONCRETE IN THAT AREA. . 8. ALL SLABS SHALL HAVE THICKENINGS, DEPRESSIONS, OPENINGS, ALL SLABS SHALL HAVE THICKENINGS, DEPRESSIONS, OPENINGS, ETC. AS SHOWN HEREIN OR ON ARCHITECTURAL, MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS. . 9. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A 185. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A 185. . 10. ALL MESH SHALL BE SPLICED SO THAT THE OVERLAP BETWEEN ALL MESH SHALL BE SPLICED SO THAT THE OVERLAP BETWEEN OUTERMOST CROSS WIRES OF EACH SHEET IS NOT LESS THAN THE SPACING OF THE CROSS WIRES PLUS 2 INCHES, UNLESS OTHERWISE SHOWN ON DRAWINGS. . 11. FOR ALL SLABS WHERE NOT OTHERWISE SPECIFIED USE STYLE FOR ALL SLABS WHERE NOT OTHERWISE SPECIFIED USE STYLE 6x6-W2.9xW2.9 W.W.F. . 12. FOR ADDITIONAL CONCRETE WORK NOT SHOWN ON STRUCTURAL FOR ADDITIONAL CONCRETE WORK NOT SHOWN ON STRUCTURAL DRAWINGS. . 13. REFER TO SPECIFICATIONS FOR CONCRETE FINISHES.REFER TO SPECIFICATIONS FOR CONCRETE FINISHES..
AutoCAD SHX Text
1. LIVE LOAD: LIVE LOAD: A. TOP SLAB LIVE LOAD 100 PSF TOP SLAB LIVE LOAD 100 PSF 100 PSF 2. DEAD LOAD: DEAD LOAD: A. STRUCTURAL AND BUILDING COMPONENTS SELF WEIGHT STRUCTURAL AND BUILDING COMPONENTS SELF WEIGHT 3. WIND LOADING PER IBC 2021 - NEW JERSEY EDITION: WIND LOADING PER IBC 2021 - NEW JERSEY EDITION: A. BASIC WIND VELOCITY (V): 135 MPH BASIC WIND VELOCITY (V): 135 MPH 135 MPH B. EXPOSURE CATEGORY: C EXPOSURE CATEGORY: C C C. RISK CATEGORY: III RISK CATEGORY: III III 4. SEISMIC LOADING PER IBC 2021 - NEW JERSEY EDITION: SEISMIC LOADING PER IBC 2021 - NEW JERSEY EDITION: A. RESPONSE ACCELERATOR: RESPONSE ACCELERATOR: S = 0.12 S = 0.191 S = 0.12 S = 0.191 S = 0.191 DS = 0.191 S = 0.04 S = 0.111 I = 0.04 S = 0.111 S = 0.111 DI = 0.111 B. SEISMIC DESIGN CATEGORY: B SEISMIC DESIGN CATEGORY: B B C. SEISMIC SITE CLASSIFICATION: E SEISMIC SITE CLASSIFICATION: E E D. IMPORTANCE FACTOR I : 1.25 IMPORTANCE FACTOR I : 1.25 E: 1.25 1.25 5. SNOW LOADING PER IBC 2021 - NEW JERSEY EDITION: SNOW LOADING PER IBC 2021 - NEW JERSEY EDITION: A. GROUND SNOW LOAD: 20 PSF GROUND SNOW LOAD: 20 PSF 20 PSF B. IMPORTANCE FACTOR: 1.10 IMPORTANCE FACTOR: 1.10 1.10 6. SPECIAL LOADS: SPECIAL LOADS: A. HANDRAILS/GUARDRAILS: IN COMPLIANCE WITH THE PROVISIONS HANDRAILS/GUARDRAILS: IN COMPLIANCE WITH THE PROVISIONS OF IBC 2021 - NEW JERSEY EDITION SEE PROJECT SPECIFICATIONS.
AutoCAD SHX Text
FLOOR PLAN
AutoCAD SHX Text
SCALE: 1/4"=1'
AutoCAD SHX Text
SECTION
AutoCAD SHX Text
SCALE: 3/8"=1'
AutoCAD SHX Text A
AutoCAD SHX Text S-1
AutoCAD SHX Text
EXISTING CONSTRUCTION
AutoCAD SHX Text
DEMOLITION NOTES
AutoCAD SHX Text
FOUNDATION CONCRETE
AutoCAD SHX Text
1. ALL DIMENSIONS AND ELEVATIONS OF EXISTING STRUCTURES SHOWN ON THE DRAWINGS ARE OBTAINED ALL DIMENSIONS AND ELEVATIONS OF EXISTING STRUCTURES SHOWN ON THE DRAWINGS ARE OBTAINED FROM AVAILABLE SOURCES AND ARE NOT GUARANTEED TO BE TRUE AND EXACT. THE CONTRACTOR SHALL VERIFY THESE DIMENSIONS AND ELEVATIONS BY ACTUAL FIELD MEASUREMENTS PRIOR TO FABRICATION OF ANY MATERIALS AND START OF WORK AND IMMEDIATELY REPORT ANY DISCREPANCIES TO THE ENGINEER..
AutoCAD SHX Text
1. REMOVE EXISTING CONSTRUCTION AS SHOWN ON PLANS. SEE SECTIONS AND DETAILS FOR EXTENT OF REMOVE EXISTING CONSTRUCTION AS SHOWN ON PLANS. SEE SECTIONS AND DETAILS FOR EXTENT OF STRUCTURE TO BE REMOVED. . 2. EXISTING STRUCTURAL STEEL FRAMING SHALL REMAIN UNLESS SPECIFICALLY NOTED ON PLAN TO BE EXISTING STRUCTURAL STEEL FRAMING SHALL REMAIN UNLESS SPECIFICALLY NOTED ON PLAN TO BE REMOVED. . 3. CONCRETE ENCASEMENT AROUND REMAINING STEEL WILL REMAIN, UNLESS NOTED OTHERWISE. CONCRETE ENCASEMENT AROUND REMAINING STEEL WILL REMAIN, UNLESS NOTED OTHERWISE. . 4. IF FIELD CONDITIONS DIFFER FROM THOSE SHOWN ON DRAWINGS, NOTIFY ENGINEER BEFORE PROCEEDING IF FIELD CONDITIONS DIFFER FROM THOSE SHOWN ON DRAWINGS, NOTIFY ENGINEER BEFORE PROCEEDING WITH DEMOLITION..
AutoCAD SHX Text
1. ALL CONCRETE SHALL BE NORMAL WEIGHT STRUCTURAL CONCRETE HAVING A DESIGN COMPRESSIVE STRENGTH AT 28 ALL CONCRETE SHALL BE NORMAL WEIGHT STRUCTURAL CONCRETE HAVING A DESIGN COMPRESSIVE STRENGTH AT 28 DAYS AS FOLLOWS: A. FOOTINGS 4,000 PSI FOOTINGS 4,000 PSI 4,000 PSI B. WALLS AND PIERS 4,000 PSI WALLS AND PIERS 4,000 PSI 4,000 PSI C. SLAB-ON-GRADE 4,000 PSI SLAB-ON-GRADE 4,000 PSI 4,000 PSI 2. NO CONCRETE SHALL BE PLACED UNTIL CONCRETE DESIGN MIXES HAVE BEEN SUBMITTED FOR EACH CLASS OF NO CONCRETE SHALL BE PLACED UNTIL CONCRETE DESIGN MIXES HAVE BEEN SUBMITTED FOR EACH CLASS OF CONCRETE NOTED ABOVE AND HAVE BEEN APPROVED BY THE ENGINEER. . 3. REINFORCING STEEL SHALL BE DEFORMED BARS OF INTERMEDIATE GRADE NEW BILLET STEEL CONFORMING TO REINFORCING STEEL SHALL BE DEFORMED BARS OF INTERMEDIATE GRADE NEW BILLET STEEL CONFORMING TO CURRENT REQUIREMENTS OF ASTM A 615, GRADE 60. LAP BARS 40 DIAMETER UNLESS OTHERWISE SHOWN. ALL HOOKS SHALL BE STANDARD HOOKS, UNLESS OTHERWISE NOTED. . 4. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A 185. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A 185. . 5. ALL MESH SHALL BE SPLICED SO THAT THE OVERLAP OF THE OUTERMOST CROSS WIRES OF EACH ADJOINING SHEET ALL MESH SHALL BE SPLICED SO THAT THE OVERLAP OF THE OUTERMOST CROSS WIRES OF EACH ADJOINING SHEET IS NOT LESS THAN THE SPACING OF THE CROSS WIRES PLUS 2 INCHES, UNLESS NOTED OTHERWISE. . 6. FOR ALL SLABS ON GRADE WHERE NOT OTHERWISE SPECIFIED, USE 6x6-W2.9xW2.9 W.W.F. FOR ALL SLABS ON GRADE WHERE NOT OTHERWISE SPECIFIED, USE 6x6-W2.9xW2.9 W.W.F. . 7. MINIMUM STEEL PROTECTION, UNLESS OTHERWISE SHOWN, SHALL BE 1-INCH FOR INTERIOR FACE OF WALLS, 2 INCHES MINIMUM STEEL PROTECTION, UNLESS OTHERWISE SHOWN, SHALL BE 1-INCH FOR INTERIOR FACE OF WALLS, 2 INCHES FOR EXTERIOR FACE OF WALLS, 3 INCHES FOR FOOTINGS AND OTHER STRUCTURAL CONCRETE DEPOSITED AGAINST GROUND, 2 INCHES FOR CONCRETE PERMANENTLY EXPOSED TO EARTH OR WEATHER. . 8. ALL STRUCTURAL MEMBERS SHALL BE POURED FOR THEIR FULL DEPTHS IN ONE OPERATION. CONSTRUCTION JOINTS, ALL STRUCTURAL MEMBERS SHALL BE POURED FOR THEIR FULL DEPTHS IN ONE OPERATION. CONSTRUCTION JOINTS, SUCH AS DAY'S POUR JOINTS, SHALL BE LOCATED IN THE MIDDLE THIRD OF THE SPAN, MAIN REINFORCING TO RUN THROUGH THE JOINT, KEY AND ROUGHEN JOINTS TO EXPOSE AGGREGATE. CONTRACTOR SHALL SUBMIT DRAWING INDICATING CONSTRUCTION JOINT LOCATIONS FOR APPROVAL. . 9. NO CONCRETE SHALL BE PLACED IN WATER. NO CONCRETE SHALL BE PLACED IN WATER. . 10. ALL SLABS ON GRADE SHALL HAVE THICKENINGS, DEPRESSIONS, OPENINGS, ETC. AS SHOWN ON OR AS REQUIRED BY ALL SLABS ON GRADE SHALL HAVE THICKENINGS, DEPRESSIONS, OPENINGS, ETC. AS SHOWN ON OR AS REQUIRED BY VARIOUS TRADES. . 11. REFER TO SPECIFICATIONS FOR CONCRETE FINISHES. REFER TO SPECIFICATIONS FOR CONCRETE FINISHES. . 12. FOR ADDITIONAL CONCRETE WORK NOT SHOWN ON STRUCTURAL DRAWINGS.FOR ADDITIONAL CONCRETE WORK NOT SHOWN ON STRUCTURAL DRAWINGS.
AutoCAD SHX Text
STRUCTURAL STEEL
AutoCAD SHX Text
1. STRUCTURAL STEEL SHALL CONFORM TO THE FOLLOWING ASTM DESIGNATIONS, LATEST EDITION: STRUCTURAL STEEL SHALL CONFORM TO THE FOLLOWING ASTM DESIGNATIONS, LATEST EDITION: A. STRUCTURAL STEEL SHAPES ASTM A992 HAVING A MINIMUM YIELD STRENGTH OF 50 KSI. STRUCTURAL STEEL SHAPES ASTM A992 HAVING A MINIMUM YIELD STRENGTH OF 50 KSI. . B. MISC SHAPES, BARS, AND PLATES - A 36 HAVING A MINIMUM YIELD STRENGTH OF 36 KS. MISC SHAPES, BARS, AND PLATES - A 36 HAVING A MINIMUM YIELD STRENGTH OF 36 KS. . C. ROUND PIPE - A 53, GRADE B HAVING A MINIMUM YIELD STRENGTH OF 35 KS. ROUND PIPE - A 53, GRADE B HAVING A MINIMUM YIELD STRENGTH OF 35 KS. . D. SQUARE AND RECTANGULAR TUBING - A 500, GRADE B HAVING A MINIMUM YIELD STRENGTH OF 46 SQUARE AND RECTANGULAR TUBING - A 500, GRADE B HAVING A MINIMUM YIELD STRENGTH OF 46 KSI. . 2. BOLTS SHALL CONFORM TO THE FOLLOWING ASTM DESIGNATIONS: HIGH STRENGTH BOLTS-A 325 OR A BOLTS SHALL CONFORM TO THE FOLLOWING ASTM DESIGNATIONS: HIGH STRENGTH BOLTS-A 325 OR A 490; ANCHOR BOLTS-F1554; STANDARD FASTENERS-A 307. . 3. ALL WELDING ELECTRODES SHALL CONFORM TO THE E-70 SERIES OF THE SPECIFICATION FOR MILD ALL WELDING ELECTRODES SHALL CONFORM TO THE E-70 SERIES OF THE SPECIFICATION FOR MILD STEEL ARC WELDING ELECTRODES ASTM A 233. . 4. ALL BOLTS SHALL BE 3/4-INCH DIAMETER, OPEN HOLES 13/16-INCH DIAMETER, UNLESS OTHERWISE ALL BOLTS SHALL BE 3/4-INCH DIAMETER, OPEN HOLES 13/16-INCH DIAMETER, UNLESS OTHERWISE SHOWN OR NOTED. . 5. ALL SHOP CONNECTIONS MAY BE HIGH STRENGTH BOLTED OR WELDED. ALL SHOP CONNECTIONS MAY BE HIGH STRENGTH BOLTED OR WELDED. 6. ALL FIELD CONNECTIONS MAY BE HIGH STRENGTH BOLTED EXCEPT WHERE DETAILS INDICATE WELDING. ALL FIELD CONNECTIONS MAY BE HIGH STRENGTH BOLTED EXCEPT WHERE DETAILS INDICATE WELDING. . 7. ALL HIGH STRENGTH BOLTED CONNECTIONS SHALL BE INSTALLED IN ACCORDANCE WITH SPECIFICATION ALL HIGH STRENGTH BOLTED CONNECTIONS SHALL BE INSTALLED IN ACCORDANCE WITH SPECIFICATION FOR STRUCTURAL JOINTS USING ASTM A 325 OR A 490 BOLTS. . 8. ALL HIGH STRENGTH BOLTED CONNECTIONS SHALL BE FULLY PRE-TENSIONED UNLESS NOTED OTHERWISE. ALL HIGH STRENGTH BOLTED CONNECTIONS SHALL BE FULLY PRE-TENSIONED UNLESS NOTED OTHERWISE. . 9. ALL HIGH STRENGTH BOLTS IN OVERSIZED HOLES SHALL BE SLIP CRITICAL. ALL HIGH STRENGTH BOLTS IN OVERSIZED HOLES SHALL BE SLIP CRITICAL. 10. ALL HIGH STRENGTH BOLTED CONNECTIONS USED FOR KICKERS AND BRACING MEMBERS WHICH ARE ALL HIGH STRENGTH BOLTED CONNECTIONS USED FOR KICKERS AND BRACING MEMBERS WHICH ARE FABRICATED WITH SLOTTED HOLES SHALL USE SLIP-CRITICAL BOLTS. IF STANDARD HOLES ARE USED, BOLTS SHALL BE FULLY PRE-TENSIONED. . 11. NO PENETRATIONS ARE PERMITTED THROUGH STRUCTURAL STEEL MEMBERS UNLESS INDICATED ON NO PENETRATIONS ARE PERMITTED THROUGH STRUCTURAL STEEL MEMBERS UNLESS INDICATED ON STRUCTURAL DRAWINGS OR APPROVED BY ENGINEER. . 12. APPROVAL OF THE ENGINEER SHALL BE MANDATORY FOR THE USE OF CUTTING TORCH IN THE FIELD. APPROVAL OF THE ENGINEER SHALL BE MANDATORY FOR THE USE OF CUTTING TORCH IN THE FIELD. . 13. DURING ERECTION, STRUCTURAL STEEL FRAME SHALL BE ADEQUATELY BRACED IN ALL LINES, TWO WAYS. DURING ERECTION, STRUCTURAL STEEL FRAME SHALL BE ADEQUATELY BRACED IN ALL LINES, TWO WAYS. . 14. CONNECTIONS SHALL BE DESIGNED PER AISC TO CARRY FULL CAPACITY OF UNIFORMLY LOADED CONNECTIONS SHALL BE DESIGNED PER AISC TO CARRY FULL CAPACITY OF UNIFORMLY LOADED MEMBER, UNLESS NOTED OTHERWISE. REACTIONS GREATER THAN FULL MEMBER CAPACITY ARE INDICATED THUS (60K) ON PLAN. . 15. ALL GROUT UNDER STEEL PLATES SHALL BE NON-SHRINK "PRE-MIX" TYPE AND SHALL HAVE A ALL GROUT UNDER STEEL PLATES SHALL BE NON-SHRINK "PRE-MIX" TYPE AND SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 5,000 PSI. . 16. FOR ALL MISCELLANEOUS STEEL CONSTRUCTION NOT SHOWN ON STRUCTURAL DRAWINGS, SEE FOR ALL MISCELLANEOUS STEEL CONSTRUCTION NOT SHOWN ON STRUCTURAL DRAWINGS, SEE ARCHITECTURAL DRAWINGS. . 17. EXPANSION BOLTS SHALL BE 3/4-INCH DIAMETER KWIK BOLT ANCHORS AS MANUFACTURED BY HILTI OR EXPANSION BOLTS SHALL BE 3/4-INCH DIAMETER KWIK BOLT ANCHORS AS MANUFACTURED BY HILTI OR APPROVED EQUIVALENT AS APPROVED BY THE ENGINEER, AND INSTALLED IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. . 18. ALL STEEL COLUMN BASE PLATES SHALL INCLUDE LEVELING PLATES AS REQUIRED FOR CONSTRUCTION. ALL STEEL COLUMN BASE PLATES SHALL INCLUDE LEVELING PLATES AS REQUIRED FOR CONSTRUCTION. . 19. ALL EXPOSED / EXTERIOR STEEL SHALL BE HOT DIPPED GALVANIZED OR STAINLESS STEEL, UNLESS ALL EXPOSED / EXTERIOR STEEL SHALL BE HOT DIPPED GALVANIZED OR STAINLESS STEEL, UNLESS OTHERWISE SHOWN ON THE DRAWINGS.
1 inch = ft.
20 20
S-2
BA
R
SC
R
EE
N
PL
AN
A N
D S
EC
TI
O N
S
SHEET No. :
CHECKED BY :DRAWN BY : DESIGN BY :
JOB No. :
DATE :
SCALE :
JG CK/AK JDT
N o.
C H
K R
EV
IS
IO
N
D
AT
E
BY
P:
\C
AD
D
P ro je ct s\ N
J\ At la nt ic C o\ At la nt ic C ty C ty \0
2U
- B al tic A ve D ra in ag e
C an al B ar S cr ee n\
U
5-
St ru ct ur al D ra w in gs
Ba r S cr ee n.
dw g
/2
1/
:3 4:
P
M
ALL DOCUMENTS PREPARED BY REMINGTON & VERNICK
ENGINEERS AND AFFILIATES ARE INSTRUMENTS OF
SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT
INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE
BY OWNER OR OTHERS ON EXTENSIONS OF THE PROJECT
OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT
WRITTEN VERIFICATION OR ADAPTATION BY REMINGTON &
VERNICK ENGINEERS AND AFFILIATES FOR THE SPECIFIC
PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND
WITHOUT LIABILITY OR LEGAL EXPOSURE TO REMINGTON
& VERNICK ENGINEERS AND AFFILIATES; AND OWNER
SHALL INDEMNIFY AND HOLD HARMLESS REMINGTON &
VERNICK ENGINEERS AND AFFILIATES FROM ALL CLAIMS,
DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR
R E S U L T I N G T H E R E F R O M .
P L A N S W H I C H D O N O T B E A R A N E M B O S S E D S E A L A R E N O T V A L I D .
NJ PROFESSIONAL ENGINEER LIC. No. 51944
JACQUELINE D. TROVATO
DATE:
(609) 645-7110, FAX (609) 645-7076
2819 FIRE ROAD, 1ST FLOOR
EGG HARBOR TOWNSHIP, NJ 08234
REMINGTON
& VERNICK
ENGINEERS
Certification of Authorization: 24 GA 28003300
WEB ADDRESS : RVE.COM
· Excellence Innovation Service·
4.21.2025
0102U025
AS NOTED
C
IT
Y O
F
AT
LA
N
TI
C
C
IT
Y D
EP
AR
TM
EN
T O
F
PU
BL
IC
W O
R
KS
C
IT
Y O
F
AT
LA
N
TI
C
C
IT
Y
AT
LA
N
TI
C
C O
U N
TY
N
EW
J
ER
SE
Y
FI
SH
ER
M
AN
'S
P
AR
K
PU
M P
ST
AT
IO
N
U
PG
R
AD
ES
AutoCAD SHX Text
GENERATOR
AutoCAD SHX Text
ELECTRICAL CONTROL ROOM
AutoCAD SHX Text B
AutoCAD SHX Text S-3
AutoCAD SHX Text A
AutoCAD SHX Text S-3
AutoCAD SHX Text
ACCESS LADDER (TYP FOR 3)
AutoCAD SHX Text
TRASH TRAP SYSTEM
AutoCAD SHX Text
TRASH TRAP SYSTEM
AutoCAD SHX Text
VERTICAL BAR RACK
AutoCAD SHX Text
GENERATOR
AutoCAD SHX Text
ELECTRICAL CONTROL ROOM
AutoCAD SHX Text B
AutoCAD SHX Text S-3
AutoCAD SHX Text A
AutoCAD SHX Text S-3
AutoCAD SHX Text 4'x10' HS-20 SINGLE LEAF HATCH, STAINLESS STEEL DIAMOND PATTERN (TYP FOR 3)
AutoCAD SHX Text SS316 W8x18
AutoCAD SHX Text 4'x4' SINGLE LEAF HATCH, STAINLESS STEEL DIAMOND PATTERN
AutoCAD SHX Text
LOCATION OF BARSCREEN SUPPORT (TYP FOR 1)
AutoCAD SHX Text SS316 W8x18
AutoCAD SHX Text SS316 W8x18
AutoCAD SHX Text 04-21-2025
AutoCAD SHX Text
FLOOR PLAN
AutoCAD SHX Text
SCALE: 1/4"=1'
AutoCAD SHX Text NOTES: 1. ALL STRUCTURAL FRAMING, ANCHOR BOLTS, AND MISC. METAL SHALL BE TYPE 316 STAINLESS STEEL UNLESS NOTED OTHERWISE. 2. CONTRACTOR SHALL PROVIDE A RAKE THAT SHALL BE 24" WIDE WITH A HANDLE THAT ALLOWS RAKE TO REACH THE BOTTOM OF BAR SCREEN FROM SURFACE. RAKE SHALL EXTEND INTO THE BAR SCREEN A MINIMUM OF 1.5 INCHES.
AutoCAD SHX Text
ROOF PLAN
AutoCAD SHX Text
SCALE: 1/4"=1'
NOTES: 1. ALL STRUCTURAL FRAMING, ANCHOR BOLTS, AND MISC. METAL SHALL BE TYPE 316 STAINLESS STEEL UNLESS NOTED OTHERWISE. 2. CONTRACTOR SHALL PROVIDE A RAKE THAT SHALL BE 24" WIDE WITH A HANDLE THAT ALLOWS RAKE TO REACH THE BOTTOM OF BAR SCREEN FROM SURFACE. RAKE SHALL EXTEND INTO THE BAR SCREEN A MINIMUM OF 1.5 INCHES.
S-3
BA
R
SC
R
EE
N
PL
AN
A N
D S
EC
TI
O N
S
SHEET No. :
CHECKED BY :DRAWN BY : DESIGN BY :
JOB No. :
DATE :
SCALE :
JG CK/AK JDT
N o.
C H
K R
EV
IS
IO
N
D
AT
E
BY
P:
\C
AD
D
P ro je ct s\ N
J\ At la nt ic C o\ At la nt ic C ty C ty \0
2U
- B al tic A ve D ra in ag e
C an al B ar S cr ee n\
U
5-
St ru ct ur al D ra w in gs
Ba r S cr ee n.
dw g
/2
1/
:3 4:
P
M
ALL DOCUMENTS PREPARED BY REMINGTON & VERNICK
ENGINEERS AND AFFILIATES ARE INSTRUMENTS OF
SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT
INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE
BY OWNER OR OTHERS ON EXTENSIONS OF THE PROJECT
OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT
WRITTEN VERIFICATION OR ADAPTATION BY REMINGTON &
VERNICK ENGINEERS AND AFFILIATES FOR THE SPECIFIC
PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND
WITHOUT LIABILITY OR LEGAL EXPOSURE TO REMINGTON
& VERNICK ENGINEERS AND AFFILIATES; AND OWNER
SHALL INDEMNIFY AND HOLD HARMLESS REMINGTON &
VERNICK ENGINEERS AND AFFILIATES FROM ALL CLAIMS,
DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR
R E S U L T I N G T H E R E F R O M .
P L A N S W H I C H D O N O T B E A R A N E M B O S S E D S E A L A R E N O T V A L I D .
NJ PROFESSIONAL ENGINEER LIC. No. 51944
JACQUELINE D. TROVATO
DATE:
(609) 645-7110, FAX (609) 645-7076
2819 FIRE ROAD, 1ST FLOOR
EGG HARBOR TOWNSHIP, NJ 08234
REMINGTON
& VERNICK
ENGINEERS
Certification of Authorization: 24 GA 28003300
WEB ADDRESS : RVE.COM
· Excellence Innovation Service·
4.21.2025
0102U025
AS NOTED
C
IT
Y O
F
AT
LA
N
TI
C
C
IT
Y D
EP
AR
TM
EN
T O
F
PU
BL
IC
W O
R
KS
C
IT
Y O
F
AT
LA
N
TI
C
C
IT
Y
AT
LA
N
TI
C
C O
U N
TY
N
EW
J
ER
SE
Y
FI
SH
ER
M
AN
'S
P
AR
K
PU
M P
ST
AT
IO
N
U
PG
R
AD
ES
AutoCAD SHX Text
TOP OF CULVERT ELEV. 2.30' ±
AutoCAD SHX Text
TOP OF FOOTING ELEV. -9.70' ±
AutoCAD SHX Text
GRADE ELEV. 6.00' ±
AutoCAD SHX Text
CONCRETE STRUCTURAL TOP SLAB, 8" THICK W/ #5@9" O.C., E.W.
AutoCAD SHX Text
T.O.S. ELEV. 7.00' ±
AutoCAD SHX Text 4'x4' ACCESS HATCH
AutoCAD SHX Text
#5@9" O.C., E.W., E.F. (TYP)
AutoCAD SHX Text
#5 DOWELS @9" O.C.,16 LONG EPOXY GROUTED (TYP)
AutoCAD SHX Text SS316 W8x18
AutoCAD SHX Text
EX. BOX CULVERT WALLS TO REMAIN
AutoCAD SHX Text SS316 L3X3X1/2 ANGLES EITHER SIDE OF BAR SCREEN, SEE DETAIL C/S-2 FOR ATTACHMENT, TYP.
AutoCAD SHX Text
SEE DETAIL 3/S-2
AutoCAD SHX Text 4'x4' ACCESS HATCH
AutoCAD SHX Text 4'x8' S.S. ACCESS HATCH (TYP FOR BOTH SIDES)
AutoCAD SHX Text
ACCESS LADDER (TYP FOR BOTH SIDES)
AutoCAD SHX Text 10'x14'-10" BARSCREEN (TYP FOR BOTH SIDES)
AutoCAD SHX Text 12"x20" CONCRETE BEAM, 12" MIN. BEARING ON EX. BOX CULVERT WALL (TYP FOR BOTH SIDES)
AutoCAD SHX Text
(2) #5 DOWELS W/14" EMBED. & 6" EMBED INTO PROP. BEAM @12" O.C.
AutoCAD SHX Text
#5@9" O.C., E.W., E.F. (TYP)
AutoCAD SHX Text
TOP OF CULVERT ELEV. 2.30' ±
AutoCAD SHX Text
GRADE ELEV. 6.00' ±
AutoCAD SHX Text
T.O.S. ELEV. 7.00' ±
AutoCAD SHX Text
CONCRETE STRUCTURAL TOP SLAB, 8" THICK W/ #5@9" O.C., E.W.
AutoCAD SHX Text
(2)#5 (TYP)
AutoCAD SHX Text
(3)#9 (TYP)
AutoCAD SHX Text
#4 TIES @4" O.C. (TYP)
AutoCAD SHX Text 12"
AutoCAD SHX Text 8"
AutoCAD SHX Text
#5 DOWEL @12" O.C. (TYP)
AutoCAD SHX Text
#5@9"O.C., 16" LONG, EPOXY GROUTED (TYP)
AutoCAD SHX Text SS316 W8x18 (TYP FOR BOTH SIDES) SEE DETAIL 3/S-2
AutoCAD SHX Text 2.5"X0.375" THICK STAINLESS STEEL PLATE BAR SCREEN, 2.375" CENTER-TO-CENTER BAR SPACING, TYP.
AutoCAD SHX Text
SS316 W12X30, SEE DETAIL 1/S-2 TYP.
AutoCAD SHX Text
BAR SCREEN BASE SUPPORT, SEE DETAIL 2/S-2
AutoCAD SHX Text
1" CLEAR OPENING BAR SCREEN
AutoCAD SHX Text
1" MESH NET
AutoCAD SHX Text
NET GUIDE RAILS
AutoCAD SHX Text
VERTICAL BAR RACK
AutoCAD SHX Text
INTERMEDIATE SUPPORT
AutoCAD SHX Text
(TYP.) AT 3'-0" O.C.
AutoCAD SHX Text C3x1.75x1.597#
AutoCAD SHX Text
SIDE RAILS (TYP.)
AutoCAD SHX Text 4"
AutoCAD SHX Text 6"
AutoCAD SHX Text
BENT PLATE (TYP.)
AutoCAD SHX Text 7 7/8"x3"x3/8"x2 1/2"
AutoCAD SHX Text 2 1/2"
AutoCAD SHX Text
STRUCTURE
AutoCAD SHX Text
MIN. 1" WIDE
AutoCAD SHX Text
SERRATED BAR
AutoCAD SHX Text
RUNGS (TYP)
AutoCAD SHX Text
RUNG SPACING @ 12" O.C.
AutoCAD SHX Text 4"
AutoCAD SHX Text 6"
AutoCAD SHX Text 1'-6"
AutoCAD SHX Text
TYP
AutoCAD SHX Text
1/4" THK. PLATE
AutoCAD SHX Text 1.5" R
AutoCAD SHX Text 3/16
AutoCAD SHX Text
TYP
AutoCAD SHX Text 12"
AutoCAD SHX Text
%%USTAINLESS STEEL LADDER DETAIL
AutoCAD SHX Text
%%USECTION VIEW
AutoCAD SHX Text
%%UFRONT VIEW
AutoCAD SHX Text N.T.S.
AutoCAD SHX Text 12" HILTI HIT-HY 20ANCHORS w/HIT-I INSERTS (3" MIN. EMBED.) (TYP FOR CMU ONLY) 12" HILTI HIT-HY 150ANCHORS w/HIT-A RODS (3 3/8" MIN. EMBED.) (TYP FOR CONC. ONLY)
AutoCAD SHX Text C
AutoCAD SHX Text S-3
AutoCAD SHX Text
BAR SCREEN
AutoCAD SHX Text SS316 4x4x "x6" LONG 14"x6" LONG EA. SIDE. (TYP)
AutoCAD SHX Text
HILTI HIT-HY 200V3 (OR APPROVED EQUAL) W/5/8" SS316 BOLTSW/6" EMBED. (TYP)
AutoCAD SHX Text
STEEL BEAM (SEE PLAN)
AutoCAD SHX Text SS316 3x3x " EA. SIDE. 12" EA. SIDE. W/HILTI HIT-HY 200V3 (OR APPROVED EQUAL) W/1/2" SS316 BOLTS @36"O.C., W/4.5" EMBED. (TYP)
AutoCAD SHX Text
STEEL BEAM (SEE PLAN)
AutoCAD SHX Text
HILTI HIT-HY 200V3 (OR APPROVED EQUAL) W/5/8" SS316 BOLTSW/6" EMBED. (TYP)
AutoCAD SHX Text
BAR SCREEN
AutoCAD SHX Text
3" COPE@ BAR SCREEN SUPPORT ANGLES
AutoCAD SHX Text SS316 3x3x "x5" LONG 12"x5" LONG EA. SIDE. W/(2) 1/2" SS316 BOLTS (TYP)
AutoCAD SHX Text
HILTI HIT-HY 200V3 (OR APPROVED EQUAL) W/1/2" SS316 BOLTSW/4.5" EMBED. (TYP)
AutoCAD SHX Text
STEEL BEAM (SEE PLAN)
AutoCAD SHX Text
BAR SCREEN
AutoCAD SHX Text SS316 3x3x " 12" EA. SIDE. (TYP)
AutoCAD SHX Text HILTI HIT-HY 200V3 (OR APPROVED EQUAL) W/1/2" SS316 BOLTS@ 30" O.C. W/4.5" EMBED. (TYP)
AutoCAD SHX Text 04-21-2025
AutoCAD SHX Text
SECTION
AutoCAD SHX Text
SCALE: 3/8"=1'
AutoCAD SHX Text A
AutoCAD SHX Text S-3
AutoCAD SHX Text
SECTION
AutoCAD SHX Text
SCALE: 3/8"=1'
AutoCAD SHX Text B
AutoCAD SHX Text S-3
AutoCAD SHX Text
SECTION
AutoCAD SHX Text
SCALE: 1"=1'
AutoCAD SHX Text C
AutoCAD SHX Text S-3
AutoCAD SHX Text
DETAIL
AutoCAD SHX Text
SCALE: 1"=1'
AutoCAD SHX Text
AutoCAD SHX Text S-3
AutoCAD SHX Text
DETAIL
AutoCAD SHX Text
SCALE: 1"=1'
AutoCAD SHX Text
AutoCAD SHX Text S-3
AutoCAD SHX Text
DETAIL
AutoCAD SHX Text
SCALE: 1"=1'
AutoCAD SHX Text
S-3
1 inch = ft.
20 20
S-4
TR
AN
SF
O
R M
ER
P
LA
N
A N
D S
EC
TI
O N
S
SHEET No. :
CHECKED BY :DRAWN BY : DESIGN BY :
JOB No. :
DATE :
SCALE :
JG CK/AK JDT
N o.
C H
K R
EV
IS
IO
N
D
AT
E
BY
P:
\C
AD
D
P ro je ct s\ N
J\ At la nt ic C o\ At la nt ic C ty C ty \0
2U
- B al tic A ve D ra in ag e
C an al B ar S cr ee n\
U
5-
St ru ct ur al D ra w in gs
Tr an sf or m er .d w g
/2
1/
:3 5:
P
M
ALL DOCUMENTS PREPARED BY REMINGTON & VERNICK
ENGINEERS AND AFFILIATES ARE INSTRUMENTS OF
SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT
INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE
BY OWNER OR OTHERS ON EXTENSIONS OF THE PROJECT
OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT
WRITTEN VERIFICATION OR ADAPTATION BY REMINGTON &
VERNICK ENGINEERS AND AFFILIATES FOR THE SPECIFIC
PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND
WITHOUT LIABILITY OR LEGAL EXPOSURE TO REMINGTON
& VERNICK ENGINEERS AND AFFILIATES; AND OWNER
SHALL INDEMNIFY AND HOLD HARMLESS REMINGTON &
VERNICK ENGINEERS AND AFFILIATES FROM ALL CLAIMS,
DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR
R E S U L T I N G T H E R E F R O M .
P L A N S W H I C H D O N O T B E A R A N E M B O S S E D S E A L A R E N O T V A L I D .
NJ PROFESSIONAL ENGINEER LIC. No. 51944
JACQUELINE D. TROVATO
DATE:
(609) 645-7110, FAX (609) 645-7076
2819 FIRE ROAD, 1ST FLOOR
EGG HARBOR TOWNSHIP, NJ 08234
REMINGTON
& VERNICK
ENGINEERS
Certification of Authorization: 24 GA 28003300
WEB ADDRESS : RVE.COM
· Excellence Innovation Service·
4.21.2025
0102U025
AS NOTED
C
IT
Y O
F
AT
LA
N
TI
C
C
IT
Y D
EP
AR
TM
EN
T O
F
PU
BL
IC
W O
R
KS
C
IT
Y O
F
AT
LA
N
TI
C
C
IT
Y
AT
LA
N
TI
C
C O
U N
TY
N
EW
J
ER
SE
Y
FI
SH
ER
M
AN
'S
P
AR
K
PU
M P
ST
AT
IO
N
U
PG
R
AD
ES
AutoCAD SHX Text A
AutoCAD SHX Text S-4
AutoCAD SHX Text
TRANSFORMER WT = 15,000 LBS (SEE NOTE 2)
AutoCAD SHX Text
42" HANDRAIL (SEE DETAIL)
AutoCAD SHX Text
CONCRETE SLAB SEE NOTE 1
AutoCAD SHX Text 54"x20" OPENING IN SLAB (CONTRACTOR TO COORDINATE EXACT LOCATION W/ TRANSFORMER MANUFACTURER)
AutoCAD SHX Text
8" X 12" CONC. BEAM W/ (2)#5 TOP & BOT. BARS. & #3 TIES @ 12" O.C.
AutoCAD SHX Text A
AutoCAD SHX Text S-4
AutoCAD SHX Text 25 TONS PILES TO BE CONCRETE FILLED 14" O.D. X 0.375" THICK STEEL PIPE PILES, DRIVEN MIN. 81' BELOW EXISTING GRADE. (TYP)
AutoCAD SHX Text
42" ALUMINUM HANDRAIL (SEE DETAIL)
AutoCAD SHX Text #5@12
AutoCAD SHX Text #6@12
AutoCAD SHX Text
1#4 (TYP.)
AutoCAD SHX Text
ABRASIVE NOSING
AutoCAD SHX Text 24"
AutoCAD SHX Text 24"
AutoCAD SHX Text
#5 DOWEL @12" O.C. (TYP)
AutoCAD SHX Text 12"
AutoCAD SHX Text 24"
AutoCAD SHX Text
#5 DOWEL @12" O.C. (TYP)
AutoCAD SHX Text
#5@12" O.C.. E.W., E.F. (TYP)
AutoCAD SHX Text 2x4 KEY. (TYP)
AutoCAD SHX Text
(4)#6 T&B LONG. W/#6@12" O.C. TRANSVERSE (TYP)
AutoCAD SHX Text 25 TONS PILES TO BE CONCRETE FILLED 14" O.D. X 0.375" THICK STEEL PIPE PILES, DRIVEN MIN. 81' BELOW EXISTING GRADE. (TYP)
AutoCAD SHX Text
GRADE ELEV. 6.00'
AutoCAD SHX Text
#5@12" O.C.. E.W. (TYP)
AutoCAD SHX Text #6x24" LONG DOWEL @12" O.C.
AutoCAD SHX Text
1" CHAMFER (TYP)
AutoCAD SHX Text
SELECT BACKFILL (TYP)
AutoCAD SHX Text
F.F. ELEV. 12.00'ELEV. 12.00'
AutoCAD SHX Text
8" X 12" CONC. BEAM W/ (2)#5 TOP & BOT. BARS. & #3 TIES @ 12" O.C.
AutoCAD SHX Text 4"%%c PIPE SLEEVE
AutoCAD SHX Text
EPOXY GROUT
AutoCAD SHX Text
GROUT.
AutoCAD SHX Text
PRESSURE INJECT EPOXY
AutoCAD SHX Text
3" ABOVE TOP OF CONC.,
AutoCAD SHX Text DRILL 1/4"%%c WEEPHOLE
AutoCAD SHX Text
SHALL BE 5'-0" (TYPICAL).
AutoCAD SHX Text
& POST, MAX. POST SPACING
AutoCAD SHX Text 1-1/2"%%c ALUM. PIPE HANDRAIL
AutoCAD SHX Text
CAULK
AutoCAD SHX Text
#5 E.F. T. & B. EXTRA BARS EQUAL TO BARS CUT AT OPENING BOTH TOP & BOTTOM
AutoCAD SHX Text
2#5 E.F. (TYP T&B)
AutoCAD SHX Text 04-21-2025
AutoCAD SHX Text
FLOOR PLAN
AutoCAD SHX Text
SCALE: 1/2"=1'
AutoCAD SHX Text
SECTION
AutoCAD SHX Text
SCALE: 1/2"=1'
AutoCAD SHX Text A
AutoCAD SHX Text S-4
AutoCAD SHX Text
FOUNDATION PLAN
AutoCAD SHX Text
SCALE: 1/2"=1'
AutoCAD SHX Text
HANDRAIL DETAIL
AutoCAD SHX Text N.T.S.
AutoCAD SHX Text NOTES: 1. STRUCTURAL SLAB TO BE 8" THICK W/#5@12" O.C. STRUCTURAL SLAB TO BE 8" THICK W/#5@12" O.C. 2. ENGINEER OF RECORD TO BE NOTIFIED PRIOR TO ENGINEER OF RECORD TO BE NOTIFIED PRIOR TO CONSTRUCTION IF UNIT WEIGHT EXCEEDS WEIGHT NOTED. 3. FINAL LOCATION FOR TRANSFORMER PAD SHALL BE PER FINAL LOCATION FOR TRANSFORMER PAD SHALL BE PER ELECTRICAL DRAWINGS. 4. ALL CONCRETE FINISHES SHALL MATCH EXISTING ALL CONCRETE FINISHES SHALL MATCH EXISTING CONSTRUCTION.
AutoCAD SHX Text NOTE: AT LEAST TWO (2) "DRIVE TEST PILES" SHOULD BE INSTALLED IN THE AREA OF THE PROPOSED STRUCTURE TO DETERMINE THE DRIVING CHARACTERISTICS AND THE REQUIRED PILE LENGTH.
AutoCAD SHX Text
ADDITIONAL REINFORCING AROUND OPENINGS
AutoCAD SHX Text N.T.S.
NOTES: "W" = DIMENSION OF OPENING PERPENDICULAR TO PRINCIPAL BARS CUT, FOR CIRCULAR OPENINGS "W" = DIAMETER. SEE MECH. & ARCH. PLANS FOR SLAB AND WALL OPENINGS NOT SHOWN ON STRUCTURAL PLANS.
R-1
BA
R
SC
R
EE
N
-T R
AS
H
T R
AP
C
O N
N
EC
TI
O
N D
ET
AI
LS
SHEET No. :
CHECKED BY :DRAWN BY : DESIGN BY :
JOB No. :
DATE :
SCALE :
JG CK/AK JDT
N o.
C H
K R
EV
IS
IO
N
D
AT
E
BY
P:
\C
AD
D
P ro je ct s\ N
J\ At la nt ic C o\ At la nt ic C ty C ty \0
2U
- B al tic A ve D ra in ag e
C an al B ar S cr ee n\
U
5-
St ru ct ur al D ra w in gs
Ba r S cr ee n-
D et ai ls
.d w g
/2 1/
:3
5:
P M
ALL DOCUMENTS PREPARED BY REMINGTON & VERNICK
ENGINEERS AND AFFILIATES ARE INSTRUMENTS OF
SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT
INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE
BY OWNER OR OTHERS ON EXTENSIONS OF THE PROJECT
OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT
WRITTEN VERIFICATION OR ADAPTATION BY REMINGTON &
VERNICK ENGINEERS AND AFFILIATES FOR THE SPECIFIC
PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND
WITHOUT LIABILITY OR LEGAL EXPOSURE TO REMINGTON
& VERNICK ENGINEERS AND AFFILIATES; AND OWNER
SHALL INDEMNIFY AND HOLD HARMLESS REMINGTON &
VERNICK ENGINEERS AND AFFILIATES FROM ALL CLAIMS,
DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR
R E S U L T I N G T H E R E F R O M .
P L A N S W H I C H D O N O T B E A R A N E M B O S S E D S E A L A R E N O T V A L I D .
NJ PROFESSIONAL ENGINEER LIC. No. 51944
JACQUELINE D. TROVATO
DATE:
(609) 645-7110, FAX (609) 645-7076
2819 FIRE ROAD, 1ST FLOOR
EGG HARBOR TOWNSHIP, NJ 08234
REMINGTON
& VERNICK
ENGINEERS
Certification of Authorization: 24 GA 28003300
WEB ADDRESS : RVE.COM
· Excellence Innovation Service·
4.21.2025
0102U025
AS NOTED
C
IT
Y O
F
AT
LA
N
TI
C
C
IT
Y D
EP
AR
TM
EN
T O
F
PU
BL
IC
W O
R
KS
C
IT
Y O
F
AT
LA
N
TI
C
C
IT
Y
AT
LA
N
TI
C
C O
U N
TY
N
EW
J
ER
SE
Y
FI
SH
ER
M
AN
'S
P
AR
K
PU
M P
ST
AT
IO
N
U
PG
R
AD
ES
AutoCAD SHX Text 04-21-2025
FOR REFERENCE PURPOSES ONLY
SHEET No. :
CHECKED BY :DRAWN BY : DESIGN BY :
JOB No. :
DATE :
SCALE :
D.M. K.M.
N o.
C H
K R
EV
IS
IO
N
D
AT
E
BY
P:
\P ro je ct s\
At la nt ic
C ity
\0
2U
5\ Sh ee ts
\E -1
.0 E le ct ric al
C ov er S he et
.d w g
/2 1/
1:
:4
AM
ALL DOCUMENTS PREPARED BY REMINGTON & VERNICK
ENGINEERS AND AFFILIATES ARE INSTRUMENTS OF
SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT
INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE
BY OWNER OR OTHERS ON EXTENSIONS OF THE PROJECT
OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT
WRITTEN VERIFICATION OR ADAPTATION BY REMINGTON &
VERNICK ENGINEERS AND AFFILIATES FOR THE SPECIFIC
PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND
WITHOUT LIABILITY OR LEGAL EXPOSURE TO REMINGTON
& VERNICK ENGINEERS AND AFFILIATES; AND OWNER
SHALL INDEMNIFY AND HOLD HARMLESS REMINGTON &
VERNICK ENGINEERS AND AFFILIATES FROM ALL CLAIMS,
DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR
R E S U L T I N G T H E R E F R O M .
P L A N S W H I C H D O N O T B E A R A N E M B O S S E D S E A L A R E N O T V A L I D .
02/2025
0102U025
AS NOTED
C
IT
Y O
F
AT
LA
N
TI
C
C
IT
Y
AT
LA
N
TI
C C
IT
Y
AT
LA
N
TI
C C
O U
N
TY
N
EW
J
ER
SE
Y
FI
SH
ER
M
AN
'S
P
AR
K
PU
M P
ST
AT
IO
N
U
PG
R
AD
ES
NJ PROFESSIONAL ENGINEER LIC. No. 56794
KAVAN R. SMITH
DATE:
(609) 645-7110, FAX (609) 645-7076
2819 FIRE ROAD, 1ST FLOOR
EGG HARBOR TOWNSHIP, NJ 08234
REMINGTON
& VERNICK
ENGINEERS
Certification of Authorization: 24 GA 28003300
WEB ADDRESS : RVE.COM
· Excellence Innovation Service·
EL
EC
TR
IC
AL
C
O
VE
R S
H
EE
T
E-1.0
JOB No. :
DATE :
SCALE :
D.M. K.M.
N o.
C H
K R
EV
IS
IO
N
D
AT
E
BY
P:
\P ro je ct s\
At la nt ic
C ity
\0
2U
5\ Sh ee ts
\E -1
.1 E le ct ric al
D em ol iti on P um p
St at io n
Pl an
.d w g
/2 1/
1:
:4
AM
ALL DOCUMENTS PREPARED BY REMINGTON & VERNICK
ENGINEERS AND AFFILIATES ARE INSTRUMENTS OF
SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT
INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE
BY OWNER OR OTHERS ON EXTENSIONS OF THE PROJECT
OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT
WRITTEN VERIFICATION OR ADAPTATION BY REMINGTON &
VERNICK ENGINEERS AND AFFILIATES FOR THE SPECIFIC
PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND
WITHOUT LIABILITY OR LEGAL EXPOSURE TO REMINGTON
& VERNICK ENGINEERS AND AFFILIATES; AND OWNER
SHALL INDEMNIFY AND HOLD HARMLESS REMINGTON &
VERNICK ENGINEERS AND AFFILIATES FROM ALL CLAIMS,
DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR
R E S U L T I N G T H E R E F R O M .
P L A N S W H I C H D O N O T B E A R A N E M B O S S E D S E A L A R E N O T V A L I D .
02/2025
0102U025
AS NOTED
C
IT
Y O
F
AT
LA
N
TI
C
C
IT
Y
AT
LA
N
TI
C C
IT
Y
AT
LA
N
TI
C C
O U
N
TY
N
EW
J
ER
SE
Y
FI
SH
ER
M
AN
'S
P
AR
K
PU
M P
ST
AT
IO
N
U
PG
R
AD
ES
NJ PROFESSIONAL ENGINEER LIC. No. 56794
KAVAN R. SMITH
DATE:
(609) 645-7110, FAX (609) 645-7076
2819 FIRE ROAD, 1ST FLOOR
EGG HARBOR TOWNSHIP, NJ 08234
REMINGTON
& VERNICK
ENGINEERS
Certification of Authorization: 24 GA 28003300
WEB ADDRESS : RVE.COM
· Excellence Innovation Service·
EL
EC
TR
IC
AL
D
EM
O
LI
TI
O N
PU
M
P
ST
AT
IO
N P
LA
N
E-1.1
ELECTRICAL DEMOLITION PUMP STATION PLAN
SCALE: 1/4"=1'-0"
JOB No. :
DATE :
SCALE :
D.M. K.M.
N o.
C H
K R
EV
IS
IO
N
D
AT
E
BY
P:
\P ro je ct s\
At la nt ic
C ity
\0
2U
5\ Sh ee ts
\E S-
2.
El ec tri ca l S ite
P la n.
dw g
/2 1/
1:
:4
AM
ALL DOCUMENTS PREPARED BY REMINGTON & VERNICK
ENGINEERS AND AFFILIATES ARE INSTRUMENTS OF
SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT
INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE
BY OWNER OR OTHERS ON EXTENSIONS OF THE PROJECT
OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT
WRITTEN VERIFICATION OR ADAPTATION BY REMINGTON &
VERNICK ENGINEERS AND AFFILIATES FOR THE SPECIFIC
PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND
WITHOUT LIABILITY OR LEGAL EXPOSURE TO REMINGTON
& VERNICK ENGINEERS AND AFFILIATES; AND OWNER
SHALL INDEMNIFY AND HOLD HARMLESS REMINGTON &
VERNICK ENGINEERS AND AFFILIATES FROM ALL CLAIMS,
DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR
R E S U L T I N G T H E R E F R O M .
P L A N S W H I C H D O N O T B E A R A N E M B O S S E D S E A L A R E N O T V A L I D .
02/2025
0102U025
AS NOTED
C
IT
Y O
F
AT
LA
N
TI
C
C
IT
Y
AT
LA
N
TI
C C
IT
Y
AT
LA
N
TI
C C
O U
N
TY
N
EW
J
ER
SE
Y
FI
SH
ER
M
AN
'S
P
AR
K
PU
M P
ST
AT
IO
N
U
PG
R
AD
ES
NJ PROFESSIONAL ENGINEER LIC. No. 56794
KAVAN R. SMITH
DATE:
(609) 645-7110, FAX (609) 645-7076
2819 FIRE ROAD, 1ST FLOOR
EGG HARBOR TOWNSHIP, NJ 08234
REMINGTON
& VERNICK
ENGINEERS
Certification of Authorization: 24 GA 28003300
WEB ADDRESS : RVE.COM
· Excellence Innovation Service·
EL
EC
TR
IC
AL
SI
TE
P
LA
N
ES-2.1
ELECTRICAL SITE PLAN
SCALE: 1"=10'
0 10' 20'
1 INCH =
GRAPHIC SCALE
10 FT.
30'
JOB No. :
DATE :
SCALE :
D.M. K.M.
N o.
C H
K R
EV
IS
IO
N
D
AT
E
BY
P:
\P ro je ct s\
At la nt ic
C ity
\0
2U
5\ Sh ee ts
\E -2
.1 E le ct ric al
P ow er P um p
St at io n
Pl an
.d w g
/2 1/
1:
:5
AM
ALL DOCUMENTS PREPARED BY REMINGTON & VERNICK
ENGINEERS AND AFFILIATES ARE INSTRUMENTS OF
SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT
INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE
BY OWNER OR OTHERS ON EXTENSIONS OF THE PROJECT
OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT
WRITTEN VERIFICATION OR ADAPTATION BY REMINGTON &
VERNICK ENGINEERS AND AFFILIATES FOR THE SPECIFIC
PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND
WITHOUT LIABILITY OR LEGAL EXPOSURE TO REMINGTON
& VERNICK ENGINEERS AND AFFILIATES; AND OWNER
SHALL INDEMNIFY AND HOLD HARMLESS REMINGTON &
VERNICK ENGINEERS AND AFFILIATES FROM ALL CLAIMS,
DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR
R E S U L T I N G T H E R E F R O M .
P L A N S W H I C H D O N O T B E A R A N E M B O S S E D S E A L A R E N O T V A L I D .
02/2025
0102U025
AS NOTED
C
IT
Y O
F
AT
LA
N
TI
C
C
IT
Y
AT
LA
N
TI
C C
IT
Y
AT
LA
N
TI
C C
O U
N
TY
N
EW
J
ER
SE
Y
FI
SH
ER
M
AN
'S
P
AR
K
PU
M P
ST
AT
IO
N
U
PG
R
AD
ES
NJ PROFESSIONAL ENGINEER LIC. No. 56794
KAVAN R. SMITH
DATE:
(609) 645-7110, FAX (609) 645-7076
2819 FIRE ROAD, 1ST FLOOR
EGG HARBOR TOWNSHIP, NJ 08234
REMINGTON
& VERNICK
ENGINEERS
Certification of Authorization: 24 GA 28003300
WEB ADDRESS : RVE.COM
· Excellence Innovation Service·
EL
EC
TR
IC
AL
P
O W
ER
PU
M P
ST
AT
IO
N
P
LA
N
E-2.1
ELECTRICAL POWER PUMP STATION PLAN
SCALE: 1/4"=1'-0"
JOB No. :
DATE :
SCALE :
D.M. K.M.
N o.
C H
K R
EV
IS
IO
N
D
AT
E
BY
P:
\P ro je ct s\
At la nt ic
C ity
\0
2U
5\ Sh ee ts
\E -5
.1 E le ct ric al
D em ol iti on S in gl e Li ne D ia gr am .d w g
/2
1/
1:
:4
AM
ALL DOCUMENTS PREPARED BY REMINGTON & VERNICK
ENGINEERS AND AFFILIATES ARE INSTRUMENTS OF
SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT
INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE
BY OWNER OR OTHERS ON EXTENSIONS OF THE PROJECT
OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT
WRITTEN VERIFICATION OR ADAPTATION BY REMINGTON &
VERNICK ENGINEERS AND AFFILIATES FOR THE SPECIFIC
PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND
WITHOUT LIABILITY OR LEGAL EXPOSURE TO REMINGTON
& VERNICK ENGINEERS AND AFFILIATES; AND OWNER
SHALL INDEMNIFY AND HOLD HARMLESS REMINGTON &
VERNICK ENGINEERS AND AFFILIATES FROM ALL CLAIMS,
DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR
R E S U L T I N G T H E R E F R O M .
P L A N S W H I C H D O N O T B E A R A N E M B O S S E D S E A L A R E N O T V A L I D .
02/2025
0102U025
AS NOTED
C
IT
Y O
F
AT
LA
N
TI
C
C
IT
Y
AT
LA
N
TI
C C
IT
Y
AT
LA
N
TI
C C
O U
N
TY
N
EW
J
ER
SE
Y
FI
SH
ER
M
AN
'S
P
AR
K
PU
M P
ST
AT
IO
N
U
PG
R
AD
ES
NJ PROFESSIONAL ENGINEER LIC. No. 56794
KAVAN R. SMITH
DATE:
(609) 645-7110, FAX (609) 645-7076
2819 FIRE ROAD, 1ST FLOOR
EGG HARBOR TOWNSHIP, NJ 08234
REMINGTON
& VERNICK
ENGINEERS
Certification of Authorization: 24 GA 28003300
WEB ADDRESS : RVE.COM
· Excellence Innovation Service·
EL
EC
TR
IC
AL
D
EM
O
LI
TI
O N
SI
N
G
LE
L
IN
E D
IA
G
R
AM
E-5.1
ELECTRICAL DEMOLITION SINGLE LINE DIAGRAM
SCALE: N.T.S
JOB No. :
DATE :
SCALE :
D.M. K.M.
N o.
C H
K R
EV
IS
IO
N
D
AT
E
BY
P:
\P ro je ct s\
At la nt ic
C ity
\0
2U
5\ Sh ee ts
\E -5
.2 E le ct ric al
S in gl e
Li ne
D ia gr am
.d w g
/2 1/
1:
:5
AM
ALL DOCUMENTS PREPARED BY REMINGTON & VERNICK
ENGINEERS AND AFFILIATES ARE INSTRUMENTS OF
SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT
INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE
BY OWNER OR OTHERS ON EXTENSIONS OF THE PROJECT
OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT
WRITTEN VERIFICATION OR ADAPTATION BY REMINGTON &
VERNICK ENGINEERS AND AFFILIATES FOR THE SPECIFIC
PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND
WITHOUT LIABILITY OR LEGAL EXPOSURE TO REMINGTON
& VERNICK ENGINEERS AND AFFILIATES; AND OWNER
SHALL INDEMNIFY AND HOLD HARMLESS REMINGTON &
VERNICK ENGINEERS AND AFFILIATES FROM ALL CLAIMS,
DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR
R E S U L T I N G T H E R E F R O M .
P L A N S W H I C H D O N O T B E A R A N E M B O S S E D S E A L A R E N O T V A L I D .
02/2025
0102U025
AS NOTED
C
IT
Y O
F
AT
LA
N
TI
C
C
IT
Y
AT
LA
N
TI
C C
IT
Y
AT
LA
N
TI
C C
O U
N
TY
N
EW
J
ER
SE
Y
FI
SH
ER
M
AN
'S
P
AR
K
PU
M P
ST
AT
IO
N
U
PG
R
AD
ES
NJ PROFESSIONAL ENGINEER LIC. No. 56794
KAVAN R. SMITH
DATE:
(609) 645-7110, FAX (609) 645-7076
2819 FIRE ROAD, 1ST FLOOR
EGG HARBOR TOWNSHIP, NJ 08234
REMINGTON
& VERNICK
ENGINEERS
Certification of Authorization: 24 GA 28003300
WEB ADDRESS : RVE.COM
· Excellence Innovation Service·
ELECTRICAL SINGLE LINE DIAGRAM
SCALE: N.T.S
EL
EC
TR
IC
AL
SI
N G
LE
L
IN
E
D
IA
G R
AM
E-5.2
JOB No. :
DATE :
SCALE :
D.M. K.M.
N o.
C H
K R
EV
IS
IO
N
D
AT
E
BY
P:
\P ro je ct s\
At la nt ic
C ity
\0
2U
5\ Sh ee ts
\E -6
.1 E le ct ric al
D et ai ls
.d w g
/2 1/
1:
:4
AM
ALL DOCUMENTS PREPARED BY REMINGTON & VERNICK
ENGINEERS AND AFFILIATES ARE INSTRUMENTS OF
SERVICE IN RESPECT OF THE PROJECT. THEY ARE NOT
INTENDED OR REPRESENTED TO BE SUITABLE FOR REUSE
BY OWNER OR OTHERS ON EXTENSIONS OF THE PROJECT
OR ON ANY OTHER PROJECT. ANY REUSE WITHOUT
WRITTEN VERIFICATION OR ADAPTATION BY REMINGTON &
VERNICK ENGINEERS AND AFFILIATES FOR THE SPECIFIC
PURPOSE INTENDED WILL BE AT OWNERS SOLE RISK AND
WITHOUT LIABILITY OR LEGAL EXPOSURE TO REMINGTON
& VERNICK ENGINEERS AND AFFILIATES; AND OWNER
SHALL INDEMNIFY AND HOLD HARMLESS REMINGTON &
VERNICK ENGINEERS AND AFFILIATES FROM ALL CLAIMS,
DAMAGES, LOSSES AND EXPENSES ARISING OUT OF OR
R E S U L T I N G T H E R E F R O M .
P L A N S W H I C H D O N O T B E A R A N E M B O S S E D S E A L A R E N O T V A L I D .
02/2025
0102U025
AS NOTED
C
IT
Y O
F
AT
LA
N
TI
C
C
IT
Y
AT
LA
N
TI
C C
IT
Y
AT
LA
N
TI
C C
O U
N
TY
N
EW
J
ER
SE
Y
FI
SH
ER
M
AN
'S
P
AR
K
PU
M P
ST
AT
IO
N
U
PG
R
AD
ES
NJ PROFESSIONAL ENGINEER LIC. No. 56794
KAVAN R. SMITH
DATE:
(609) 645-7110, FAX (609) 645-7076
2819 FIRE ROAD, 1ST FLOOR
EGG HARBOR TOWNSHIP, NJ 08234
REMINGTON
& VERNICK
ENGINEERS
Certification of Authorization: 24 GA 28003300
WEB ADDRESS : RVE.COM
· Excellence Innovation Service·
EL
EC
TR
IC
AL
D
ET
AI
LS
E-6.1
ELEVATED CONCRETE TRANSFORMER PAD DETAIL
N.T.S.
TRANSFORMER PAD SECTION DETAIL
N.T.S.
0102U025 - FULL SET FOR SIGNATURES
Final Audit Report 2025-04-22
Created: 2025-04-22
By: Brian Zoppel (Brian.Zoppel@rve.com)
Status: Signed
Transaction ID: CBJCHBCAABAAcgAdYFCmxvuPzQdJSekgkJ18-8EsqFKR
"0102U025 - FULL SET FOR SIGNATURES" History Document created by Brian Zoppel (Brian.Zoppel@rve.com)
2025-04-22 - 12:07:22 PM GMT
Document emailed to Kavan Smith (kavan.smith@rve.com) for signature
2025-04-22 - 12:15:26 PM GMT
Email sent to ken.morey@rve.com bounced and could not be delivered
2025-04-22 - 12:16:02 PM GMT
Email viewed by Kavan Smith (kavan.smith@rve.com)
2025-04-22 - 1:27:26 PM GMT
Document e-signed by Kavan Smith (kavan.smith@rve.com) Signature Date: 2025-04-22 - 1:28:08 PM GMT - Time Source: server
Document emailed to JT (jacqueline.trovato@rve.com) for signature
2025-04-22 - 1:28:23 PM GMT
Email viewed by JT (jacqueline.trovato@rve.com)
2025-04-22 - 1:29:08 PM GMT
Document e-signed by JT (jacqueline.trovato@rve.com) Signature Date: 2025-04-22 - 1:32:02 PM GMT - Time Source: server
Document emailed to ND (nicholas.dicosmo@rve.com) for signature
2025-04-22 - 1:32:17 PM GMT
Email viewed by ND (nicholas.dicosmo@rve.com)
2025-04-22 - 3:05:35 PM GMT
Document e-signed by ND (nicholas.dicosmo@rve.com) Signature Date: 2025-04-22 - 3:06:18 PM GMT - Time Source: server
Agreement completed.
2025-04-22 - 3:06:18 PM GMT
| 2025.04.21 - 0102U025 - Fisherman's Park - Electrical.pdf |
| Sheets and Views |
| E-1.0 Electrical Cover Sheet |
| E-1.1 Electrical Demolition Pump Station Plan |
| Electrical Power Pump Station Plan - V |
| ES-2.1 Electrical Site Plan |
| Electrical Site Plan - V |
| E-2.1 Electrical Power Pump Station Plan |
| Electrical Power Pump Station Plan - V |
| E-5.1 Electrical Demolition Single Line Diagram |
| E-5.2 Electrical Single Line Diagram |
| E-6.1 Electrical Details |
| 2025-04-22T15:07:05+0000 | |
| Certified by Adobe Acrobat Sign |
File details come from the government source that posted it. Updated .