This document is a detailed architectural engineering drawing for exterior elevations of an Emergency Department (ED) deck, specifically focusing on suicide mitigation fencing for a Veterans Affairs project. The drawings, prepared by INOVA Architects/Engineers, show multiple elevation views (North and West) of Building 02-ED deck, illustrating the proposed suicide prevention infrastructure with precise architectural measurements and details. The drawings include specific grid references, dimensional notations (ranging from 100' - 0" to 119' - 0"), and a comprehensive list of consulting engineers and specialists involved in the project, including structural, mechanical, electrical, plumbing, and fire protection experts. A Request for Information (RFI) note indicates the emergency signage location is 105' from the end of the ramp. The drawing set is part of the Office of Construction & Facilities Management project documentation, with the specific drawing number R2AS270, and includes an exterior materials legend and wall type legend to provide additional technical specificity.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
02-L1 100' - 0"
02-L2 119' - 0"
ED
ED
ED
ED
R2AS272
02-L1 100' - 0"
02-L2 119' - 0"
ED
F
ED
G
ED
H EDI ED J ED
K
ED
L
ED
M
ED
N
ED
O
STR-L4.6
107' - 2"
PRECAST CONCRETE BOLLARDS
03 48 13
REMOVABLE
02-L1 100' - 0"
02-L2 119' - 0"
ED
D
ED
F
02-L1 100' - 0"
02-L2 119' - 0"
02 502 3.3
ED
ED
1 02 6ED
ED
ED
2.1
R2AS272
G2
F2
E2
D2
G1
F1
E1
D1
PLAN
NORTH
DATE
LOCATION
CHECKED DRAWN
PROJECT TITLE PROJECT NUMBER
DOCUMENT SET PACKAGE
DRAWING NUMBERAPPROVED: PROJECT DIRECTOR
DRAWING TITLEARCHITECT/ENGINEERS:CONSULTANTS:
REVISIONS: DATE
B
A
D
C
E
VA FORM 08-6231
O N
E
EI
G H
T
IN
C H
O
N E
FO
O
T O
N E
Q U
AR
T E
R
IN
C H
O
N E
FO
O
T O
N E
H
AL
F I N
C H
O
N E
FO
O
T
TH
R
EE
Q U
A R
TE
R S
IN
C
H
O N
E
FO
O T
TH
R
EE
IN
C H
ES
O N
E
FO
O T
O N
E
IN
C H
F
O R
TY
F
EE
T
( 1
0'
6"
6"
0'
0'
123456
F
B
A
D
C
E
F
O N
E
SI
XT
EE
N
TH
IN
C
H
O N
E
FO
O T
O N
E
AN
D O
N E
H
AL
F
IN
C H
E S
O N
E
FO
O T
6"
BUILDING NUMBER
NEW ORLEANS, LOUISIANA
R2AS270
BLDG. 02 -ED DECK EXTERIOR ELEVATIONS
DV JGJanuary 23, 2013
02629-HS2-401SLVHCS REPLACEMENT MEDICAL
CENTER PROJECT
SCHRENK & PETERSON CONSULTING ENGINEERS / CIVIL
KORDA/NEMETH ENGINEERING / STRUCTURAL
BR+A CONSULTING ENGINEERS / MECH, ELECT, PLUMBING, LOW VOLTAGE
ARCHITECTURAL ENGINEERING / PLUMBING
SCALES ASSOCIATES / FIRE PROTECTION
DESMAN ASSOCIATES / PARKING
CODE CONSULTANTS, INC. / CODE CONSULTANT
THE SEXTANT GROUP / AV & ACOUSTICAL
HAMMER DESIGN ASSOCIATES / FOOD SERVICE
PYBURN & ODOM / ABATEMENT
TATA & HOWARD / TANK CONSULTANT
Department of Veterans Affairs
OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
EWP_06
CONSTRUCTION DOCUMENTS 1
FULLY SPRINKLERED
SCALE: 1/8" = 1'-0"
ELEVATION WEST AREA E.3 - ED DECK2
SCALE: 1/8" = 1'-0"
ELEVATION NORTH AREA F.3 - ED DECK1
MATERIAL TYPES
GLAZING TYPES
SYMBOLS LEGEND
INSULATED LAMINATED
VISION
METAL PANEL (MP-1 AND MP-1A)
PRECAST
EXTERIOR MATERIALS LEGEND
DIMENSION NOTES
1. ALL DIMENSION STRINGS FROM C/L OF JT. TO C/L OF JT.
EXCEPT AT ENDS OF EXTERIOR WALL & U.N.O.
2. REFER TO PLANS FOR CW. VERT. FRAMING LOCATIONS.
REFER TO ELEVATIONS FOR FRIT PATTERN EXTENT
3. REFER TO PLANS FOR WINDOW LOCATIONS IN METAL
PANEL & PRECAST SYSTEMS. REFER TO ELEVATIONS FOR
LOCATIONS OF JOINTS IN THESE SYSTEMS.
4. REFER TO PLANS AND ELEVATIONS FOR MP SYSTEM
LOCATIONS WITH C.M.U BACKUP.
INSULATED LAMINATED SPANDREL
MECHANICAL LOUVER.
SEE NOTE FOR ACTIVE LOUVER DIM.
O.D OVERFLOW DRAIN (SECONDARY)
O.S OVER FLOW SCUPPER
M.E.P. FP PENETRATIONS THROUGH
ENCLOSURE
LIGHTING OVER EXIT
PRECAST (PC) REPEATING JOINT
PATTERN TYPE INDICATOR. SEE SHEET
OAS5__ FOR PATTERN TYPES
WALL TYPES LEGEND
X
STUCCO / E.I.F.S (SEE NOTE ON ELEV.)
METAL PANEL (MP-1)
IG-01 INSULATED LAMINATED VISION
IG-01F INSUL. LAMINATED VISION W/50%
COVERAGE FRIT PATTERN
IG-01E INSUL. LAMINATED VISION
W/TRANSLUCENT PVB
IG-01x-T INSUL. LAMINATED VISION TEMPERED
IG-01T-IB INSUL. LAMINATED VISION SAFETY W/
INTERIOR VISION CONTROL GLASS UNIT
IG-01DT-IB SAME AS IG-01T-IB, EXCEPT LAMINATED
GLASS ON INT. AND EXT. SIDE OF I.G.U
SG-01 INSUL. LAMINATED SPANDREL
SG-01F INSUL. LAMINATED SPANDREL W/ 50%
FRIT PATTERN
SG-01xT INSUL. LAMINATED SPANDREL
TEMPERED
IG-02 INSUL. LAMINATED VISION
SG-02 INSUL. LAMINATED SPANDREL
SG-03 INSUL. LAMINATED SPANDREL
SLG-01 SAFETY IMPACT LAMINATED GLAZING
LGS-1 LAMINATED GLASS SPANDREL
WALL TYPE MARK REFER TO SHEET
0AS501
0AS503
0AS504
PC
CW-1, PC-3
MP-1, 1A
SCALE: 1/8" = 1'-0"
ELEVATION NORTH AREA E.3 - ED DECK5
SCALE: 1/8" = 1'-0"
ELEVATION WEST AREA D.3 & E.3 - ED DECK4
6 BULLETIN 010C 01/23/2013
RFI 3806: Non-rated Removable Security Bollards
RFI 04189: Location of Emergency Signage is 105' from end of ramp
RFI 4032: Bollard to be steel in lieu of precast.
File details come from the government source that posted it. Updated .