0016272 ITS Sandy Springs Firestation _3 (sta.pdf

PDF 7 MB Posted

Attached to
25-043 S2102 ITS Fire Station #3
Solicitation number
PE-66098-NONST-2025-000000086
Issued by
Fulton County, Georgia

About this file

The project involves Intelligent Transportation Systems (ITS) infrastructure installation for City of Sandy Springs Fire Station #3, located in Fulton County, Georgia. The project encompasses fiber optic cable installation, conduit work, and communications infrastructure along Heards Ferry Road NW, Riverside Drive, and Raider Drive, with a project length of 0.790 miles. The work includes installing 144-fiber loose tube single-mode fiber optic cables, directional boring, conduit placement, pull boxes, splice closures, and associated communications equipment at the fire station and along the specified roadways. The project is designed to enhance municipal communications infrastructure and is scheduled for completion by August 12, 2024.

The project is funded through the City of Sandy Springs Public Works Department and will be executed by Atlas Technical Consultants. The total project is located 100% within Congressional District No. 13 and will involve coordinating with local utility services, maintaining existing traffic signal and communications infrastructure, and ensuring minimal disruption to current operations. The design incorporates Georgia State Highway Department standards, includes erosion control measures, and requires specific coordination with city departments for field switch selection and communication downtime management. The contract appears to be a lump sum bid with comprehensive requirements for installation, splicing, and integration of fiber optic communications systems.

View the file

Other files

File Type Posted
Special Provisions.pdf PDF
25_043 S2102 ITS Fire Station _3.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

28-0001

PROJECT LOCATION

@ RIVERSIDE DR

HEARDS FERRY DR NW

PROJECT LIMITS BEGIN

STATION 00+00.00

@ RIVERSIDE DR

HEARDS FERRY DR NW

PROJECT LIMITS BEGIN

STATION 07+78.02

RAIDER DR @ FIRESTATION #3

PROJECT LIMITS END

8/12/2024

Kyle.Wagner

GPLOT-ORD

gplotborder-ORD-PO.tbl

28-0001.dgn

5:51:55 PM

GPLN4/28/2016

DRAWING No.

P.I. No.

770.263.5945 Duluth, Georgia 30096

Suite 100 2450 Commerce Avenue

150 600

SCALE IN FEET

0 300

0016272

PLANS COMPLETED 08-12-2024

PLANS PREPARED BY:

APPROVAL BY:

RECOMMENDED FOR

CITY OF SANDY SPRINGS

ATLAS TECHNICAL CONSULTANTS

OF GEORGIA AND SHALL BE DEEMED TO MEAN THE DEPARTMENT OF TRANSPORTATION.

OR "DEPARTMENT" WHEN THE CONTEXT THEROF MEANS THE STATE HIGHWAY DEPARTMENT

DEPARTMENT", "GEORGIA STATE HIGHWAY DEPARTMENT", "HIGHWAY DEPARTMENT",

THIS DOCUMENT TO "STATE HIGHWAY DEPARTMENT OF GEORGIA", "STATE HIGHWAY

DOCUMENTS, DRAWINGS OR PHOTOGRAPHS USED TO BE USED IN CONNECTION WITH

ALL REFERENCES IN THIS DOCUMENT, WHICH INCLUDES ALL PAPERS, WRITINGS,

NOTE:

102.04.102.05 AND 104.03 OF THESPECIFICATIONS.

TRANSPORTATION IN ANYWAY THE ATTENTION OF BIDDER IS SPECIFICALLY DIRECTED TO SUBSECTIONS

SAME ARE SHOWN AS INFORMATION ONLY, ARE NOT GUARANTEED AND DO NOT BIND THE DEPARTMENT OF

FIELD INVESTIGATIONS AND ARE BELIEVED TO BE INDICATIVE OF ACTUAL CONDITIONS, HOWEVER, THE

INDICATED THEREBY, WHETHER BY DRAWINGS OR NOTES, OR IN ANY OTHER MANNER, ARE BASED UPON

THE DATA TOGETHER WITH ALL OTHER INFORMATION SHOWN ON THESE PLANS OR IN ANYWAY

OF 1988.

AMERICAN VERTICAL DATUM (NAVD)

1983)/94 WEST ZONE AND THE NORTH

COORDINATE SYSTEM OF 1984 (NAD

USING THE HORIZONTAL GEORGIA

THIS PROJECT HAS BEEN PREPARED

REVISIONS

GROSS LENGTH OF PROJECT

NET LENGTH OF EXCEPTIONS

NET LENGTH OF PROJECT

NET LENGTH OF BRIDGES

NET LENGTH OF ROADWAY

LENGTH OF PROJECT

MILES

COUNTY No. 121

0016272

Project No.

HEARDS FERRY RD NW -MAJOR COLLECTOR

RAIDER DR AND RIVERSIDE DR - MINOR ARTERIAL

100% IN CONG. DIST. NO. 13

FULTON COUNTY AND IS

THIS PROJECT IS 100% IN

LOCATION SKETCH

DESIGN DATA:

SPEED DESIGN: 35 mph

R I

V E R S I

D E

R

RAIDER DR

H E

A R

D S

C R E

K

R I

V E

R S I

PUBLIC WORKS DEPARTMENT

CITY OF SANDY SPRINGS

ITS FIRESTATION #3

ITS PLANS

FEDERAL ROUTE # N/A

STATE ROUTE # N/A

HEARDS FERRY DR NW

RAIDER DR

HEARDS FERRY DR NW

H E

A R

D S

C R E

S V

C

PB

PB

00.790 MILES

00.790 MILES

00.790 MILES

00.000 MILES

00.000 MILES

+0

+0

+0

+0

+0

Robinson.Nicol Image

ITS PLANS

28-0002

REVISION DATES

3/31/2025

Kyle.Wagner

GPLOT-ORD

28-0002 -Dino's Copy.dgn

5:29:13 PM

DRAWING No.CHECKED:

BACKCHECKED:

CORRECTED:

VERIFIED:

DATE:

DATE:

DATE:

DATE:

P.I. No.

770.263.5945 Duluth, Georgia 30096

ITS FIRESTATION #3

CITY OF SANDY SPRINGS

0016272

DRAWING NO. DESCRIPTION DRAWING NO. DESCRIPTION

28-0001

28-0002

28-0003

28-0004

28-0005

28-0006

28-0007 - 28-0009

28-0012

28-0013

28-0014 - 28-0016

28-0010 - 28-0011

ITS PLANS

FIRESTATION LAYOUT

COVER

INDEX

GENERAL NOTES

LEGEND

QUANTITIES

LAYOUT

SPLICING DIAGRAM

FIBER ALLOCATION TABLE

CONSTRUCTION DETAIL

52-0001

52-0002

52-0003

52-0004

52-0005

52-0006

52-0007

EROSION CONTROL LEGEND & UNIFORM CODE SHEET

EC-L1: EROSION CONTROL & UNIFORM CODE SHEET(SHEET 1 OF 7)(03/2017)

EC-L2: EROSION CONTROL & UNIFORM CODE SHEET(SHEET 1 OF 7)(11/2018)

EC-L3: EROSION CONTROL & UNIFORM CODE SHEET(SHEET 1 OF 7)(03/2017)

EC-L4: EROSION CONTROL & UNIFORM CODE SHEET(SHEET 1 OF 7)(03/2017)

EC-L5: EROSION CONTROL & UNIFORM CODE SHEET(SHEET 1 OF 7)(03/2017)

EC-L6: EROSION CONTROL & UNIFORM CODE SHEET(SHEET 1 OF 7)(11/2018)

EC-L7: EROSION CONTROL & UNIFORM CODE SHEET(SHEET 1 OF 7)(03/2017)

54-0001 TYPICAL BMP DETAIL

28-0003

Kyle.Wagner

GPLOT-ORD

28-0003 - Dino's Copy.dgn

1:59:57 PM

BACKCHECKED:

CORRECTED:

VERIFIED:

DATE:

DATE:

DATE:

DATE:

P.I. No.

770.263.5945 Duluth, Georgia 30096

0016272

ITS GENERAL NOTES

THE PROJECT. (CITY WILL PROVIDE FIELD SWITCH)

13. THE CONTRACTOR SHALL COORDINATE WITH THE CITY OF SANDY SPRINGS DEPARTMENT OF PUBLIC WORKS FOR INSTRUCTIONS ON WHAT BRAND OF FIELD SWITCH TO USE FOR

CONSTRUCTION WORK BEING PERFORMED.

ANY REQUIRED COMUNICATION DOWNTIME NEEDED FOR FOC SPLICING WITH COSS DEPT OF PUBLIC WORKS A MINIMUM OF 14 DAYS IN ADVANCE OF SCHEDULES

THE CONTRACTOR SHALL MAINTAIN COMMUNICATIONS TO RIVERSIDE DR / HEARDS FERRY RD NW AND RAIDER DR / FIRESTATION #3 AT ALL TIMES. CONTRACTOR SHALL COORDINATE 12.

CABLES WTIH THE FOLLOWING INFORMATION CAUTION FIBER OPTIC CABLE XXF CITY OF SANDY SRINGS (XX DENOTES FIBER COUNT. TO BE ATTACHED TO PROPOSED FIBER OPTIC

THE CONTRACTOR SHALL COORDINATE WITH THE CITY OF SANDY SPRINGS DEPARTMENT OF PUBLIC WORKS AT 770.730.5600 TO PICK-UP PROVIDED LABELS/TAGS 11.

10. ALL TRAFFIC CONTROL SHALL BE PAID FOR UNDER THE ITS LUMP SUM BID.

LUMP SUM BID. SEE DETAILS

9. ALL EROSION CONTROL MEASURES REQUIRED TO ENSURE COMPLIANCE WITH STATE AND FEDERAL LAW, REGULATIONS AND GUIDELINES SHALL BE PAID FOR UNDER THE ITS

ALL PULLBOX LIDS SHALL BE LABELED COSS COMMMUNICATIONS. 8.

COMMUNICATIONS SERVICES TO EXISTING TRAFFIC SIGNALS AND CCTV CAMERAS.

7. THE CONTRACTOR SHALL INCLUDE IN THE LUMP SUM BID, ALL COSTS ASSOCIATED WITH MODIFYING EXISTING COMMUNICATIONS SERVICES AND ESTABLISHING NEW

QUANTITIES SHOWN IN THE PLAN ARE FOR INFORMATION ONLY.

6. THE CONTRACTOR SHALL DETERMINE THE MATERIALS AND QUANTITIES REQUIRED TO CONSTRUCT THE PLAN AS SHOWN FOR A LUMP SUM BID. THE LIST OF MATERIALS AND

SHALL INCLUDE THE COSTS AS PART OF THE ITS LUMP SUM BID.

GRASSING, UTILITY SERVICE LINE, STORM DRAIN PIPE, MASONRY WALL AND PAVING THAT IS REMOVED, DAMAGED OR DESTROYED DUE TO CONTRACTORS ACTIVITY. THE CONTRACTOR

5. THE CONTRACTOR SHALL REPLACE IN KIND ANY SIZE, ANY BARRIER WALL, FENCE, SITCH PAVING, CURBING, SIDEWALK, GUTTER, SLOPE PAVEMENT, SIGN, GUARDRAIL, LANDSCAPING, INOPERABLE DURING CONSTRUCTION, THE CONTRACTOR SHALL FIRST NOTIFY THE CITY OF SANDY SPRINGS DEPARTMENT OF PUBLIC WORKS AT 770.730.5600.

GDOT SPECIAL PROVISION 150 REGARDING RESONSIBILITIES. IF ANY PART OF THE EXISTING TRAFFIC SIGNALS OR COSS COMMUNICATIONS INFRASTRUCTURE SHOULD BECOME

THE PROJECT LIMITS DURING CONSTRUCTION UNTIL FINAL ACCEPTANCE. THE CONTRACTOR SHALL MAKE REFERENCE TO GDOT SPECIFICATION SECTIONS 104 AND 107 AND

4. THE CONTRACTOR SHALL MAINTAIN THE FULL FUNCTIONALITY AND OPERATION OF ALL EXISTING TRAFFIC SIGNALS AND COSS COMMUNICATIONS INFRASTRUCTURE WITHIN

AT 770.730.5600 PRIOR TO THE COMMENCEMENT OF ANY CONSTRUCTION ACTIVITY.

3. THE CONTRACTOR SHALL CONTACT THE 811 UTILITY LOCATION SERVICE AT 1-800-282-7411 AND THE CITY OF SANDY SPRINGS DEPARTMENT OF PUBLIC WORKS

770.730.5600 PRIOR TO FINAL ACCEPTANCE.

2. THE COMPLETED INSTALLATION SHALL BE CHECKED AND ACCEPTED BY THE CITY OF SANDY SPRINGS DEPARTMENT OF PUBLIC WORKS AT

CITY OF SANDY SPRINGS SPECIAL PROVISIONS 108, AND 210 THE NATIONAL ELECTRIC CODE (NEC).

1. THE COMPLETED INSTALLATION SHALL CONFORM TO GDOT STANDARDS AND DETAILS, GDOT STANDARD SPECIFICATIONS 615, 682, 935, AND

28-0004

8/9/2024

Kyle.Wagner

GPLOT-ORD

28-0004.dgn

1:50:45 PM

BACKCHECKED:

CORRECTED:

VERIFIED:

DATE:

DATE:

DATE:

DATE:

P.I. No.

770.263.5945 Duluth, Georgia 30096

0016272

EXISTING UTILITIES COMMUNICATION ITEMS

EX. SD MANHOLE

EX. DROP INLET

EX. CATCH BASIN

EX. STORM DRAIN

EX. UG CABLE TV

EX. OH CABLE TV

EX. UG TELEPHONE

EX. TELEPHONE POLE

EX. OH TELEPHONE

EX. TELEPHONE MH

EX. SS MANHOLE

EX. SANITARY SEWER

EX. WATER VALVE

EX. WATER METER

EX. FIRE HYDRANT

EX. WATER LINE

EX. GAS VALVE

EX. GAS METER

EX. GAS LINE

EX. UG ELECTRIC

EX. TRANSFORMER

EX. POWER POLE

EX. OH ELCTRIC

EXISTING GUY WIRE

PROPOSED GUY ASSEMBLY

PROPOSED SIGNAL CABINET

EXISTING SIGNAL CABINET

PROPOSED AERIAL SLACK LOOP

EXISTING AERIAL SLACK LOOP

EXISTING AERIAL CLOSURE

PROPOSED AERIAL CLOSURE

EXISTING CONDUIT W/ PROPOSED UNDERGROUND COMMUNICATIONS

PROPOSED UNDERGROUND TRENCHED FIBER COMMUNICATIONS

PROPOSED BORE W/ UNERGROUND FIBER COMMUNICATIONS

EXISTING UNDERGROUND FIBER COMMUNICATIONS

EXISTING AERIAL FIBER COMMUNICATIONS

PROPOSED AERIAL FIBER COMMUNICATIONS

PROPOSED TYPE 7 PULL BOX

PROPOSED TYPE 6 PULL BOX

PROPOSED TYPE 2 PULL BOX

EXISTING STRAIN POLE

EXISTING CCTV CAMERA

PROPOSED CCTV CAMERA

SD

WV

WM

FH

GV

GV

28-0005

Kyle.Wagner

GPLOT-ORD

28-0005 - Copy 3-26-25.dgn

2:02:53 PM

BACKCHECKED:

CORRECTED:

VERIFIED:

DATE:

DATE:

DATE:

DATE:

P.I. No.

770.263.5945 Duluth, Georgia 30096

0016272

28-0006

PB

PB

00+00

01+ 00

02+00

03+00

04+00

05 +00

06+00

07+00

07+00

08 +00

09 +00

10+0011+0012 +00

1 3+00

14+00

15+00

16+00

1 7+0018+0 0

19+00

20 +00

21 +00

22+ 00

23+00

24+00

25+00

26+00

27+00

28+00

29+00

30+00

31+00

32+00

33+00

01+00

02+00

03+00

04+00

05+00

06+00

07+00

08+00

09+00

DATE$$$

$USER$

$PRF8$

$$PENTABLE$$

$DGN$

R

E F

R

E F

R

E F

R

E F

R

E F

TIME$$$

R

E F

R

E F

R

E F

R

E F

R

E F

R

E F

R

E F

R

E F

R

E F

R

E F

GPLN4/28/2016

DRAWING No.CHECKED:

BACKCHECKED:

CORRECTED:

VERIFIED:

DATE:

DATE:

DATE:

DATE:

P.I. No.

0016272

150 600

SCALE IN FEET

0 300

770.263.5945 Duluth, Georgia 30096

RAIDER DR

H E

A R

D S

C R E

R I

V E

R S I

R I

V E R S I

HEARDS FERRY DR NW

HEARDS FERRY DR NW

SHEET 28-0007SHEET 28-0008

SHEET 28-0009

28-0007

M A

T C

H L

IN

E

S H

E E

T

-0

$USER$

$PRF8$

$$PENTABLE$$

$DGN$

R

E F

R

E F

R

E F

R

E F

R

E F

TIME$$$

R

E F

R

E F

R

E F

R

E F

R

E F

R

E F

R

E F

R

E F

R

E F

R

E F

GPLN4/28/2016

DRAWING No.CHECKED:

BACKCHECKED:

CORRECTED:

VERIFIED:

DATE:

DATE:

DATE:

DATE:

P.I. No.

770.263.5945 Duluth, Georgia 30096

50 200

0 100

ITS FIRESTATION #3

CITY OF SANDY SPRINGS

ITS LEGEND

0016272

HEARDS FERRY RD NW

HEARDS FERRY RD NW

R I

V E

R S I

R I

V E

R S I

OSP F/O CABLE, LOOSE TUBE, SM, 144 FIBER (560 LF)

CONDUIT, NM, TP 3, 2-2 IN (1120 LF)

5 IN DIRECTIONAL BORE (560 LF)

INSTALL:

OSP F/O CABLE, LOOSE TUBE, SM, 144 FIBER (750 LF)

CONDUIT, NM, TP 3, 2-2 IN (1500 LF)

5 IN DIRECTIONAL BORE (750 LF)

INSTALL:

SEE DETAIL #7

DETAIL #7

PB

PROPOSED TYPE 7 PULL BOX

EXISTING PULL BOX

EXISTING SIGNAL CABINET

FIBER COMMUNICATION

PROPOSED BORE W/ UNDERGROUND

OSP F/O CABLE, LOOSE TUBE, SM, 144 FIBER (110 LF)

PULLBOX, TP 7

INSTALL:

SEE THE SPLICING DIAGRAM SHEET FOR SPLICING DETAILS

SPLICE REMAINING 48F TRUNK FIBERS TO PROPOSED 144F TRUNK FIBERS

FIBER OPTIC SPLICE, FUSION, (68 EA)

OSP, F/O CABLE, LOOSE TUBE, SM, 144 FIBER (110 LF)

OSP, F/O CABLE, DROP, SM, 12 FIBER (55 LF)

REPLACE WITH F/O CLOSURE, UNDERGROUND, 144 FIBER (1 EA)

INSTALL:

OSP, F/O CABLE, LOOSE TUBE, SM, 48 FIBER

OSP, F/O CABLE, DROP, SM, 6 FIBER

F/O CLOSURE, UNDERGROUND, 48 FIBER WITH SPLICES

IN EXISTING PULLBOX:

SFP, FIBER MODULE, TYPE 1 (1 EA)

FIELD SWITCH, TYPE B (3 PORT)(CITY WILL PROVIDE FIELD SWITCH)

FIBER PATCH CORDS LC TO LC INCLUDED PER GDOT SPEC 935

REPLACE WITH FIBER PATCH PANEL, WALL MOUNTED, 12 FIBER.

INSTALL:

FIELD SWITCH WTIH 2 SFP TYPE 1

FIBER PATCH PANEL, WALL MOUNTED, 6 FIBER

IN EXISTING CABINET:

EXIST R/W

EXIST R/W EXIST R/W

EXIST R/W

EXIST R/W

EXIST R/W

PB

PB

M A

T C

H L

IN

E

S H

E E

T

-0

MATCHLINE SHEET 28-0009

M A

T C

H L

IN

E

S H

E E

T

-0

28-0008

$USER$

$PRF8$

$$PENTABLE$$

$DGN$

R

E F

R

E F

R

E F

R

E F

R

E F

TIME$$$

R

E F

R

E F

R

E F

R

E F

R

E F

R

E F

R

E F

R

E F

R

E F

R

E F

GPLN4/28/2016

DRAWING No.CHECKED:

BACKCHECKED:

CORRECTED:

VERIFIED:

DATE:

DATE:

DATE:

DATE:

P.I. No.

770.263.5945 Duluth, Georgia 30096

0 100

ITS FIRESTATION #3

CITY OF SANDY SPRINGS

ITS LEGEND

0016272

HEARDS FERRY RD NW

HEARDS FERRY RD NW

OSP F/O CABLE, LOOSE TUBE, SM, 144 FIBER (190 LF)

CONDUIT, NM, TP 3, 2-2 IN (380 LF)

5 IN DIRECTIONAL BORE (190 LF)

INSTALL:

OSP F/O CABLE, LOOSE TUBE, SM, 144 FIBER (110 LF)

PULLBOX, TP 7

INSTALL:

OSP F/O CABLE, LOOSE TUBE, SM, 144 FIBER (740 LF)

CONDUIT, NM, TP 3, 2-2 IN (1480 LF)

5 IN DIRECTIONAL BORE (740 LF)

INSTALL:

OSP F/O CABLE, LOOSE TUBE, SM, 144 FIBER (110 LF)

PULLBOX, TP 7

INSTALL:

OSP F/O CABLE, LOOSE TUBE, SM, 144 FIBER (575 LF)

CONDUIT, NM, TP 3, 2-2 IN (1150 LF)

5 IN DIRECTIONAL BORE (575 LF)

INSTALL:

PB

PROPOSED TYPE 7 PULL BOX

EXISTING PULL BOX

EXISTING SIGNAL CABINET

FIBER COMMUNICATION

PROPOSED BORE W/ UNDERGROUND

EXIST R/W

EXIST R/W

EXIST R/W

EXIST R/WEXIST R/W

EXIST R/W

S V

C

S V

C

S V

CS

V

C

S V

C

S V C

S V

C

S V

C

S V

C

S V

C

MAT

CH

LI

NE

S

HE

ET

8-

MATCHLINE SHEET 28-0007

28-0009

FIRESTATION #3

$USER$

$PRF8$

$$PENTABLE$$

$DGN$

R

E F

R

E F

R

E F

R

E F

R

E F

Design File and Plot Substitution information

TIME$$$

R

E F

R

E F

R

E F

R

E F

R

E F

R

E F

R

E F

R

E F

R

E F

R

E F

GPLN4/28/2016

DRAWING No.CHECKED:

BACKCHECKED:

CORRECTED:

VERIFIED:

DATE:

DATE:

DATE:

DATE:

P.I. No.

770.263.5945 Duluth, Georgia 30096

0 100

ITS FIRESTATION #3

CITY OF SANDY SPRINGS

ITS LEGEND

0016272

RAIDER DR

H E A R D S

F E R R Y

R D

N

W

OSP F/O CABLE, LOOSE TUBE, SM, 144 FIBER (110 LF)

PULLBOX, TP 7

INSTALL:

OSP F/O CABLE, LOOSE TUBE, SM, 144 FIBER (110 LF)

PULLBOX, TP 7

INSTALL:

OSP F/O CABLE, LOOSE TUBE, SM, 144 FIBER (500 LF)

CONDUIT, NM, TP 3, 2-2 IN (1000 LF)

5 IN DIRECTIONAL BORE (500 LF)

INSTALL:

OSP F/O CABLE, LOOSE TUBE, SM, 144 FIBER (110 LF)

PULLBOX, TP 7

INSTALL:

OSP F/O CABLE, LOOSE TUBE, SM, 144 FIBER (20 LF)

CONDUIT, NM, TP 3, 2-2 IN (40 LF)

5 IN DIRECTIONAL BORE (20 LF)

INSTALL:

OSP F/O CABLE, LOOSE TUBE, SM, 144 FIBER (410 LF)

CONDUIT, NM, TP 3, 2-2 IN (820 LF)

5 IN DIRECTIONAL BORE (410 LF)

INSTALL:

OSP F/O CABLE, LOOSE TUBE, SM, 144 FIBER (230 LF)

CONDUIT, NM, TP 3, 2-2 IN (460 LF)

5 IN DIRECTIONAL BORE (230 LF)

INSTALL:

OSP F/O CABLE, DROP, SM, 12 FIBER (40 LF)

CONDUIT, NM, TP 3, 2-2 IN 80 LF)

5 IN DIRECTIONAL BORE (40 LF)

INSTALL:

OSP F/O CABLE, LOOSE TUBE, SM, 144 FIBER (125 LF)

CONDUIT, NM, TP 3, 2-2 IN (250 LF)

5 IN DIRECTIONAL BORE (125 LF)

INSTALL:

OSP F/O CABLE, LOOSE TUBE, SM, 144 FIBER (110 LF)

PULLBOX, TP 7

INSTALL:

OSP F/O CABLE, LOOSE TUBE, SM, 144 FIBER (75 LF)

CONDUIT, NM, TP 3, 2-2 IN (150 LF)

5 IN DIRECTIONAL BORE (75 LF)

INSTALL:

DETAIL #9A

SEE DETAIL #9A

SEE DETAIL #9

DETAIL #9

OSP F/O CABLE, DROP, SM, 12 FIBER (55 LF)

OSP F/O CABLE, LOOSE TUBE, SM, 144 FIBER (110 LF)

F/O SPLICE FUSION (1 EA) (4 ACTUAL SPLICES)

F/O CLOSURE, UNDERGROUND, 12 FIBER, (1 EA)

PULLBOX, TP 7 (1 EA)

INSTALL:

OSP F/O CABLE, LOOSE TUBE, SM, 144 FIBER (110 LF)

PULLBOX, TP 7

INSTALL:

PROPOSED TYPE 7 PULL BOX

EXISTING PULL BOX

EXISTING SIGNAL CABINET

FIBER COMMUNICATION

PROPOSED BORE W/ UNDERGROUND

PB

SFP FIBER MODULE, TYPE 1 (2 EA)

FIBER PATCH CORDS LC TO LC INCLUDED PER GDOT SPEC 935

FIBER PATCH PANEL, WALL MOUNT, 12 PORT (1 EA)

INSTALL IN EXISTING CABINET:

E X I S T

R

W

E X I S T

R

W

E X I S T

R

W

EX

IS

T R/

W

EXI

ST

R/W

EXIST R/W

F E

N C

P B

P B

+0

+0

+0

+0

+0

+0

+0

28-0010

2/7/2025

Kyle.Wagner

GPLOT-ORD

28-0010_firestation - Dino's Copy.dgn

Design File and Plot Substitution information

11:55:36 AM

BACKCHECKED:

CORRECTED:

VERIFIED:

DATE:

DATE:

DATE:

DATE:

P.I. No.

770.263.5945 Duluth, Georgia 30096

0016272

ON THE NEXT SHEET

BRICK AND ROUTE TO THE COMMUNICATIONS ROOM AS SHOWN

ON THE OUTSIDE OF THE BUILDING AND PUSH THROUGH THE

CONTRACTOR SHALL STRAP THE 2 INCH CONDUIT AS SHOWN

17 FT

NOT TO SCALE

ALL 90 DEGREE COUPLINGS SHALL BE INCLUDED IN THE COST OF THE RIGID CONDUIT.

NOTE:

28-0011

Kyle.Wagner

GPLOT-ORD

28-0011_firestation Dino's Copy 3-26-25.dgn

5:42:39 PM

BACKCHECKED:

CORRECTED:

VERIFIED:

DATE:

DATE:

DATE:

DATE:

P.I. No.

770.263.5945 Duluth, Georgia 30096

0016272

FIRESTATION #3

ROOM

COMMUNICATION

ROOM

ELECTRICAL

FIRE ENGINE BAY

CONDUIT FROM BREAKER BOX TO POWER OUTLET

CONTRACTOR SHALL ROUTE 1 INCH RIGID

OUTLET ON WALL BY PROPOSED RACK

CONTRACTOR TO INSTALL POWER

SFP, FIBER MODULE, TYPE 2 (2 EA)

FILED SWITCH, TYPE E, (1 EA)

F/O CLOSURE, RACK MOUNTED, 144 FIBER (1 EA)

PROPOSED WALL MOUNTED RACK

INSTALL

30 FT

25 FT

10 FT

60 FT

NOT TO SCALE

ALL 90 DEGREE COUPLINGS SHALL BE INCLUDED IN THE COST OF THE RIGID CONDUIT.

NOTE:

SEE NOTE

AND LAYER 3 SWITCH

COMMUNICATION ROOM AND INSTALL THE RACK FOR A 144 FDC

CMU BLOCK AT THE CEILING TO THE ELECTRICAL ROOM TO

CONTRACTOR SHALL ROUTE 2 INCH RIGID CONDUIT ALONG THE

FOR POWER OR USE EXISTING SPARE CIRCUIT BREAKER

CONTRACTOR SHALL INSTALL BREAKER SWITCH

EXISTING PANEL BOARD

28-0012

R

IV

E R

S

ID

E D

R

COMM ROOM

FIRESTATION

144 FDC

FIRESTATION #3

SPLICE CLOSURE

UNDERGROUND

T O

I -2

S T

O R

IV

E

R V

A L

L E

Y R

D

HEARDS FERRY DR NW

AT RIVERSIDE DR

HEARDS FERRY

R A

ID

E

R D

R

SPLICE CLOSURE

UNDERGROUND

S

M F

C O

S S

-S

-D

12 FDC

EXISTING 48 SMF BLUE TUBE OF THE 48

COSS-SO01 144 SMF SLATE/GRAY TUBE OF 144 SMF

COSS-SO01 144 SMF BLUE TUBE OF 144 SMF

S

M F

C O

S S

-S

-D

12 FDC

AT RAIDER DR

HEARDS FERRY

COSS-SO01 144 SMF ORANGE, GREEN, BROWN, TUBES OF 144 SMF

COSS-SO01 144 SMF BLACK, RED, WHITE, TUBES OF 144 SMF

T O

F

2/7/2025

Kyle.Wagner

GPLOT-ORD

28-0012 - Dino's Copy.dgn

12:05:04 PM

BACKCHECKED:

CORRECTED:

VERIFIED:

DATE:

DATE:

DATE:

DATE:

P.I. No.

770.263.5945 Duluth, Georgia 30096

HEARDS FERRY RD NW

0016272

ALL 144 FIBERS TO 144 FDC

CONTRACTOR SHALL TERMINATE

ORANGE,GREEN,BROWN

48 FIBER TUBES

EXISTING REMAINING

TO 144 FDC

28-0013

$USER$

$PRF8$

$$PENTABLE$$

$DGN$

R

E F

R

E F

R

E F

R

E F

R

E F

Design File and Plot Substitution information

TIME$$$

R

E F

R

E F

R

E F

R

E F

R

E F

R

E F

R

E F

R

E F

R

E F

R

E F

GPLN4/28/2016

DRAWING No.CHECKED:

BACKCHECKED:

CORRECTED:

VERIFIED:

DATE:

DATE:

DATE:

DATE:

P.I. No.

770.263.5945 Duluth, Georgia 30096

HEARDS FERRY RD NW

28-0014

Kyle.Wagner

GPLOT-ORD

28-0014.dgn

5:09:45 PM

BACKCHECKED:

CORRECTED:

VERIFIED:

DATE:

DATE:

DATE:

DATE:

P.I. No.

770.263.5945 Duluth, Georgia 30096

28-0015

Kyle.Wagner

GPLOT-ORD

28-0015.dgn

4:51:51 PM

BACKCHECKED:

CORRECTED:

VERIFIED:

DATE:

DATE:

DATE:

DATE:

P.I. No.

770.263.5945 Duluth, Georgia 30096

28-0016

Kyle.Wagner

GPLOT-ORD

28-0016.dgn

5:03:19 PM

BACKCHECKED:

CORRECTED:

VERIFIED:

DATE:

DATE:

DATE:

DATE:

P.I. No.

770.263.5945 Duluth, Georgia 30096

52-0001

Kyle.Wagner

GPLOT-ORD

52-0001.dgn

3:53:56 PM

BACKCHECKED:

CORRECTED:

VERIFIED:

DATE:

DATE:

DATE:

DATE:

P.I. No.

770.263.5945 Duluth, Georgia 30096

52-0002

Kyle.Wagner

GPLOT-ORD

52-0002.dgn

3:58:44 PM

BACKCHECKED:

CORRECTED:

VERIFIED:

DATE:

DATE:

DATE:

DATE:

P.I. No.

770.263.5945 Duluth, Georgia 30096

52-0003

Kyle.Wagner

GPLOT-ORD

52-0003.dgn

4:05:11 PM

BACKCHECKED:

CORRECTED:

VERIFIED:

DATE:

DATE:

DATE:

DATE:

P.I. No.

770.263.5945 Duluth, Georgia 30096

52-0004

Kyle.Wagner

GPLOT-ORD

52-0004.dgn

4:09:20 PM

BACKCHECKED:

CORRECTED:

VERIFIED:

DATE:

DATE:

DATE:

DATE:

P.I. No.

770.263.5945 Duluth, Georgia 30096

52-0005

Kyle.Wagner

GPLOT-ORD

52-0005.dgn

4:12:59 PM

BACKCHECKED:

CORRECTED:

VERIFIED:

DATE:

DATE:

DATE:

DATE:

P.I. No.

770.263.5945 Duluth, Georgia 30096

52-0006

Kyle.Wagner

GPLOT-ORD

52-0006.dgn

4:18:32 PM

BACKCHECKED:

CORRECTED:

VERIFIED:

DATE:

DATE:

DATE:

DATE:

P.I. No.

770.263.5945 Duluth, Georgia 30096

52-0007

Kyle.Wagner

GPLOT-ORD

52-0007.dgn

4:21:38 PM

BACKCHECKED:

CORRECTED:

VERIFIED:

DATE:

DATE:

DATE:

DATE:

P.I. No.

770.263.5945 Duluth, Georgia 30096

BMP LOCATION DETAILS

MAT

CH

LI

NE

S

HE

ET

8-

MATCHLINE SHEET 28-0007

54-0001

FIRESTATION #3

$USER$

$PRF8$

$$PENTABLE$$

$DGN$

R

E F

R

E F

R

E F

R

E F

R

E F

Design File and Plot Substitution information

TIME$$$

R

E F

R

E F

R

E F

R

E F

R

E F

R

E F

R

E F

R

E F

R

E F

R

E F

GPLN4/28/2016

DRAWING No.CHECKED:

BACKCHECKED:

CORRECTED:

VERIFIED:

DATE:

DATE:

DATE:

DATE:

P.I. No.

770.263.5945 Duluth, Georgia 30096

0 100

ITS FIRESTATION #3

CITY OF SANDY SPRINGS

0016272

RAIDER DR

H E A R D S

F E R R Y

R D

N

W

SEE DETAIL #9

DETAIL #9

SODDING (Ds4)

E X I S T

R

W

E X I S T

R

W

E X I S T

R

W

EX

IS

T R/

W

EXI

ST

R/W

EXIST R/W

Ds4

Ds4

**TYPICAL BMP LOCATION DETAIL**

F E

N

P B

+0

+0

+0

+0

+0

+0

+0

00016272_28-0001
00016272_28-0002
00016272_28-0003
00016272_28-0004
00016272_28-0005
00016272_28-0006
00016272_28-0007
00016272_28-0008
00016272_28-0009
00016272_28-0010
00016272_28-0011
00016272_28-0012
00016272_28-0013
00016272_28-0014
00016272_28-0015
00016272_28-0016
00016272_52-0001
00016272_52-0002
00016272_52-0003
00016272_52-0004
00016272_52-0005
00016272_52-0006
00016272_52-0007
00016272_54-0001

File details come from the government source that posted it. Updated .