Sewage Lift Pumps Replacement in Shasta County
Closed State & local contract opportunity Posted
- Solicitation number
- 02A2346
- State
- California
- Responses due
Opportunity facts
- UNSPSC codes
Opportunity details come from caleprocure.ca.gov. Updated .
About this opportunity
The California Department of Transportation (Caltrans) has issued Invitation for Bid (IFB) 02A2346 for a sewage lift pumps replacement project located in Shasta County, specifically at the Caltrans District 02 Office Building Complex in Redding, CA. The procurement involves disconnecting, removing, and legally disposing of two existing sewage ejector pumps and replacing them with two new Macerator/Grinder 1hp 208V3hp sewage ejector pumps and associated piping. Contractors must possess either a valid C-36 (Plumbing Contractors) or B-General Building Contractor license and have Confined Space Entry Training Certification. Key project dates include a mandatory site inspection on December 10, 2024, and January 2, 2025, at 10:00 a.m., with written questions due by December 13, 2024. Bid submissions are due on January 7, 2025, at 2:00 p.m., with bid opening at 2:30 p.m. the same day, and an estimated award date of January 14, 2025. The contract term is projected to run from April 1, 2025, through March 31, 2026.
The procurement includes a 25% Small Business (SB) participation goal, with no mandatory Disabled Veteran Business Enterprise (DVBE) requirement, though DVBE participation is encouraged with a potential 5% incentive for 100% DVBE participation. Contractors are allowed to subcontract, and must complete the GSPD-05-105 Bidder Declaration form detailing any proposed subcontractors and their certification status. Prevailing wages apply if the total bid amount exceeds $15,000, and a payment bond of 100% is required for bids over $25,000. The total bid amount must not exceed $461,000, with a project budget set at $180,000.00. Bidders must comply with specific technical requirements, including mounting, anchoring, and seismic restraint systems for new 4-inch copper or steel vent piping in accordance with California Building Codes. All proposed work must be completed within the specified infrastructure at the Caltrans facility, which includes a sewage lift pump pit measuring 5'3" x 4'3" x 9'.
Opportunity text
The documents and files attached to this solicitation do not have any updates for digital accessibility at this time. Updates will be applied as soon as they are available. For an accessible version of solicitation documents published on this page, please submit a request at http://bit.ly/dpac-ada or call (916) 654-2852. 1. Contractor shall furnish all labor, tools, materials, supplies, permits, parts, equipment, travel, disposal fees, and incidentals necessary to disconnect, remove, and legally dispose of two (2) existing sewage ejector pumps and replace with two (2) Contractor supplied sewage ejector pumps and piping to Caltrans.
Files
| File | Type | Posted |
|---|---|---|
| IFB_02A2346.pdf | ||
| Addendum_3.pdf | ||
| Addendum_4.pdf | ||
| Addendum_1.pdf | ||
| Addendum_2.pdf |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Similar opportunities
- Ask GovTribe AI about this opportunity