McDowell WRRF Primary Clarifiers and Influent Pump Station Rehabilitation
Closed State & local contract opportunity Posted
- Solicitation number
- FY27-ITBCon-10
- State
- North Carolina
- Responses due
Opportunity facts
- Jurisdictions
- Point of contact
-
- Katherine Osborne katherine.osborne@charlottenc.gov (704) 344-6305
Opportunity details come from constructionbidsource.com. Updated .
About this opportunity
Charlotte Water is requesting sealed bids for the McDowell WRRF Primary Clarifiers and Influent Pump Station Rehabilitation project, with bids due July 28, 2026 at 10:00 a.m. and a pre-bid conference and site visit scheduled for July 14, 2026 at 10:00 a.m. at McDowell WWTP, 4901 Neck Road, Huntersville, North Carolina. An MWSBE participation goal of 2.00% applies to this project.
The scope encompasses demolition and installation of Primary Clarifier No. 4 and No. 5 mechanisms; replacement of pinch valves in BTB No. 3 and No. 4 Rate Control Structures with new plug valves; replacement of grit suction and discharge piping, valves, and appurtenances within the Headworks and Influent Pumping Station; replacement of knife gate valves on the discharge header of the first stage pumps with new plug valves; and rehabilitation of existing slide gates at Primary Clarifier No. 4, No. 5, and the Headworks and Influent Pumping Station.
All prospective bidders must complete and submit an Information Security Agreement available at charlottewater.org, unless the firm has submitted this form within the past five years. Bid security is required in accordance with Article 8 of the Instructions to Bidders. Bidding documents are available through Richa Graphics at http://planroom.richa.com. Addenda and clarifications will be posted on the City of Charlotte's Procurement Portal at https://charlottenc.bonfirehub.com. Pre-bid conference attendance is highly encouraged but not mandatory. North Carolina law applies, and the owner reserves the right to reject any or all bids.
Opportunity text
This project will generally include the demolition and installation of Primary Clarifier No. 4 and Primary Clarifier No. 5 mechanisms. This project also includes replacement of pinch valves in BTB No. 3 and BTB No. 4 Rate Control Structures with new plug valves. Within the Headworks and Influent Pumping Station, grit suction and discharge piping, valves, and appurtenances will be replaced. Knife gate valves on the discharge header of the first stage pumps will also be replaced with new plug valves. This project includes rehabilitation of existing slide gates at Primary Clarifier No. 4, Primary Clarifier No. 5, and the Headworks and Influent Pumping Station.