El Paso Water Utilities is requesting sealed bids for the McCombs 30-inch Well Collector Line Replacement project, a large-scale water main installation and associated infrastructure work, with bids due September 2, 2026.

The scope comprises unit-price items across multiple water-main pipe materials and diameters: approximately 132 linear feet of 6-inch PVC (Class 305), 2,850 linear feet of 8-inch PVC (Class 305), 5,056 linear feet of 12-inch PVC (Class 305), and 78 to 11,457 linear feet of DI pipe ranging 8 to 42 inches in diameter (Class 350). The project also includes installation of steel casing via boring method in diameters from 24 to 54 inches (540 to 270 linear feet per size), vertical gate valves from 16 to 42 inches with manhole assemblies, air/vacuum combination and blow-off valve assemblies, tapping sleeves with valves, and a 30-inch wet-tap gate valve. Ancillary work includes removal and installation of fire hydrant assemblies, 101 water service reconnections, removal and replacement of curb and gutter, sidewalk, concrete driveway, and concrete culvert box, and pavement resurfacing with HMAC and crushed stone base.

The project is located in El Paso County and El Paso City, Texas. No estimated contract value, contract term, incumbent contractor, evaluation criteria, or pre-bid meeting information is provided in the source material.

Opportunity text

The project will be comprised of unit price items to include the Installation of approximately 132 linear feet of 6-inch Polyvinyl Chloride (PVC) water main (Class 305); Installation of 2,850 linear feet of 8-inch PVC water main (Class 305); Installation of 5,056 linear feet of 12-inch PVC water main (Class 305); Installation of 78 linear feet of 8-inch Ductile Iron (DI) water main (Class 350); 559 linear feet of 12-inch DI water main (Class 350); 5,160 linear feet of 16-inch DI water main (Class 350); 4,685 linear feet of 24-inch DI water main (Class 350); 11,457 linear feet of 30-inch DI water main (Class 350); 7,615 linear feet of 36- inch DI water main (Class 350); 2,220 linear feet of 42-inch DI water main (Class 350); 540 linear feet of 24-inch Diameter Steel Casing via Boring Method; 160 linear feet of 42-inch Diameter Steel Casing via Boring Method; 270 linear feet of 48-inch Diameter Steel Casing via Boring Method; 70 linear feet of 54- inch Diameter Steel Casing via Boring Method; 6 16-inch Vertical Gate Valves with manhole assemblies; 7 24-inch Vertical Gate Valves with manhole assemblies; 15 30-inch Vertical Gate Valves with manhole assemblies; 8 36-inch Vertical Gate Valves with manhole assemblies; 2 42-inch Vertical Gate Valves with manhole assemblies; 3 4-inch air/vacuum combination valve assemblies; 14 6-inch air/vacuum combination valve assemblies; 13 6-inch Blow-Off Valve with Manhole assemblies; 2 24x8 tapping sleeves with valve; 1 42x30 tapping sleeve with valve; 1 30-inch wet-tap gate valve; removal and salvage of 6 existing fire hydrant assemblies; install 7 new fire hydrant assemblies; 101 -inch water service reconnections; remove and replace 1,745 linear feet of curb and gutter; remove and replace 511 square yards of sidewalk; remove and replace 519 square yards of concrete driveway; remove and replace 40 linear feet of 8x3-feet of Concrete Culvert Box; replacement of 16,833 square yards 2-inch HMAC pavement and 6-inch Crushed Stone Base Course; installation of 16,628 square yards of 2-sac; mill and overlay 92,619 square yards of existing pavement; Installation of 213 linear feet of 12-inch PVC Sewer main (SDR-26); replacement of 3 4 sewer service lines; repair 143 4 to 8 sewer services; repair 400 linear feet of 8 sewer main; repair 221 linear feet of 12 sewer main; repair 10 linear feet of 15 sewer main; repair 200 linear feet of 18 sewer main; repair 40 linear feet of 24 sewer main; installation of 2 48-inch diameter concrete manhole including 14 linear feet of additional depth beyond 6 feet and 14 vertical feet of cured-in-place liner; 8 Line Stops at connection points; implement sewer and water bypasses, installation of Cathodic Protection Test Stations, and all miscellaneous piping, valve, fittings, and appurtenances and other site work necessary for the proper installation of this project as shown in the plans and technical specifications.