IDOC-ROB-Sprinkler System-SH
Closed State & local contract opportunity Posted
- Solicitation number
- 24-426DOC-ROBIN-B-41261
- State
- Illinois
- Responses due
Opportunity facts
- Jurisdiction
- UNSPSC codes
- 46171647 Flammable vapour detector
- 72101509 Fire protection system and equipment maintenance or repair service
- 72101516 Fire extinguisher inspection maintenance and repair service
- 72151102 Fire sprinkler system installation service
- 72151103 Irrigation sprinkler system installation service
- 73151702 Fire protection material treatment services
Opportunity details come from bidbuy.illinois.gov. Updated .
About this opportunity
The State of Illinois, through the Illinois Department of Corrections (IDOC), is seeking contractors to establish a 5-year contract for the quarterly inspection, routine maintenance, and repair of the sprinkler systems located at the IDOC's Robinson Correctional Center. The contract requires the successful vendor to provide skilled labor to perform the required services in accordance with NFPA 25 Standards for the sprinkler systems located in the facility's Dietary, Warehouse, Maintenance, and C-Building areas. Bids must be submitted electronically through the BidBuy procurement system by the April 12, 2024 due date. The contract will be funded by the State of Illinois, and the total payments shall not exceed a maximum amount to be determined prior to contract execution.
There are no small business, minority, women, or veteran-owned business set-aside goals identified for this procurement. The State may partially or totally fund the contract with federal funds, and vendors must comply with prevailing wage requirements, as applicable. The required vendor disclosure form focuses on vendor compliance and disclosure requirements rather than specific details about the contract opportunity, such as pricing terms, incumbents, or funding sources.
Opportunity text
Contract is to establish quarterly inspection, repair and maintenance of the sprinkler systems per NFPA 25 Standards. The sprinkler systems are located in Dietary, Warehouse, Maintenance and C-Building.
Files
| File | Type | Posted |
|---|---|---|
| Robinson - Sprinkler System Inspections RM B-41261 IFB~2.docx | DOCX document | |
| Vendor Disclosure - formerly Forms A~11.docx | DOCX document | |
| U-Plan B-41261.pdf | ||
| ipg-active-registered-vendor-disclosure-(formerly-forms-b)-v.23.1 (1)~4.docx | DOCX document |