IDOC - Hood Systems Inspections and Repair
Closed State & local contract opportunity Posted
- Solicitation number
- 26-426DOC-CENTR-B-49960
- State
- Illinois
- Responses due
Opportunity facts
- Jurisdiction
- NIGP codes
- 91023 Firestop Systems (Includes Installation And Fireproofing)
- 93609 Alarm Equipment Maintenance/Repair (Fire, Etc.)
- 93632 Fire Fighting Equipment Maintenance And Repair
- 93633 Fire Protection Equipment And Systems Including Fire Hydrants, Fire Sprinkler Systems, Smoke Detectors, Jaws Of Life, Fire Protection Material Treatment, Firestop And Fire Barriers, Etc.inspection, Maintenance And Repair
- UNSPSC codes
- 72101509 Fire protection system and equipment maintenance or repair service
- 73151702 Fire protection material treatment services
- 72151102 Fire sprinkler system installation service
- 46171647 Flammable vapour detector
- 72101516 Fire extinguisher inspection maintenance and repair service
- 92121702 Fire alarm maintenance or monitoring
- 72151103 Irrigation sprinkler system installation service
Opportunity details come from bidbuy.illinois.gov. Updated .
About this opportunity
The Illinois Department of Corrections (IDOC) is seeking a qualified vendor to perform semi-annual inspections, testing, repair, and maintenance of fire suppression hood systems at the Centralia Correctional Center located in Madison County, Illinois. The contract will span two years with the potential for extensions up to ten years, focusing on comprehensive servicing of four fire suppression hood systems (three Ansul R-102 models and one Range Guard RG-6G model). Required services include detailed inspections of system components such as installation, appliances, ducts, nozzles, seals, detectors, electrical interlocks, piping, pressure gauges, and fusible links, as well as testing of automatic actuation and remote pull stations. The vendor must provide on-site services Monday through Friday between 7:30 a.m. and 4:00 p.m., excluding holidays, with rapid response capabilities (next business day for standard requests and within four hours for emergencies). Vendor qualifications include the ability to replace system components, provide technical phone support, and comply with National Fire Protection Association (NFPA) standards and manufacturer guidelines. The proposal was posted on November 6, 2025, with responses due by November 13, 2025.
This procurement is designated as a small purchase with a Small Business Set-Aside, indicating preferential opportunities for small business enterprises. Vendor requirements include maintaining comprehensive books and records for three years, complying with prevailing wage requirements, and ensuring all on-site technicians pass security background checks, including drug screening. The contractor must supply all labor, equipment, tools, materials, and genuine manufacturer parts, and provide monthly itemized invoices along with a comprehensive annual report on system condition. While specific award values are not explicitly stated, the contract will be executed through the State of Illinois' BidBuy system with pricing to be determined. Contractors must adhere to standard state terms and conditions, including $1,000,000 general commercial liability insurance and $1,000,000 auto liability coverage. The contract remains contingent upon fund appropriation and can be terminated for cause, convenience, or suspended if funding becomes unavailable.
Opportunity text
This contract will be a 2-year contract for Semi-Annual Testing/Inspections of the facility's fire suppression hood systems, as well as any repair and maintenance required.