Central Energy Plant Heat Recovery Steam Generator Assessment & Rehab

Closed State & local contract opportunity Posted

Solicitation number
ITB-08926
State
Florida
Responses due

Opportunity facts

Jurisdiction

Opportunity details come from vendor.myfloridamarketplace.com. Updated .

About this opportunity

The Central Florida Tourism Oversight District (CFTOD or the District) is soliciting proposals from qualified contractors to provide repair and inspection services for the Heat Recovery Steam Generator (HRSG) located at the Magic Kingdom Central Energy Plant in Lake Buena Vista, Florida. The HRSG was commissioned in 1988 and is a 1x1x1 system with a GE LM6000 gas turbine, which was upgraded in 2006. The District is seeking contractors experienced in the installation, replacement, or repair of high temperature/high pressure hot water and steam systems, who can comply with all relevant local, state, and federal codes and standards, including but not limited to ASME Code for Pressure Piping, B31.1 - Power Piping. Contractors must provide cost estimates for repairing any known or discovered deficiencies in the HRSG, and the District will complete an analysis and evaluation of the collected data and information in a future effort. The bid is due on May 20, 2024.

The District has bid preferences for local vendors, veteran small businesses, and opportunity zone businesses on most solicitations. The Invitation to Bid does not provide any information about incumbent vendors, current contractors, or the anticipated award value or budget range for this project.

Opportunity text

SCOPE OF SERVICES
The Central Florida Tourism Oversight District (CFTOD or DISTRICT) is soliciting proposals from 'qualified' Contractors (Contractor) to provide repair and inspection services to the CFTOD Heat Recovery Steam Generator (HRSG) located at the Magic Kingdom Central Energy Plant (CEP) in order to correct known deficiencies and gather data and information through observation, direct inspection, investigation, and indirect monitoring and reporting. The CEP is located at 5300 Center Drive, Lake Buena Vista, FL 32830. See Exhibit A for project specific location.

The term 'qualified' is defined as any individual, firm, corporation or company that, either in person or through representative, is engaged in and is responsible for the installation, replacement or repair of high temperature/high pressure hot water and steam systems; is experienced in such work and familiar with all precautions required; and has complied with all the requirements of local, state and federal codes and standards, including but not limited to American Society of Mechanical Engineers (ASME) Code for Pressure Piping, B31.1 - Power Piping. For all known and found deficiencies, provide cost estimate for repair/correction. An analysis and evaluation of the collected data and information will be completed in a future effort.

Description of the HRSG:
Year Commissioned 1988
System Configuration 1x1x1.
Gas Turbine OEM and Type GE LM6000 - Upgraded in 2006 from LM5000.
Gas Turbine Fuel Natural Gas or DO
HRSG OEM Henry Vogt Machine Co.
Pressure Triple (600#/150#/15#)
Reheat No
Burner OEM Coen
Burner Fuel Natural Gas
SCR No
CO Catalyst Yes
Deaerator Type Standalone
Type of Operation Base Load