Ashcroft Pressure Gauges
Closed State & local contract opportunity Posted
- Solicitation number
- SS-26-00359
- State
- Florida
- Responses due
Opportunity facts
- Jurisdiction
- NIGP codes
- UNSPSC codes
- 25173109 Differential Global Positioning System (DGPS) Local Area Augmentation System (LAAS)
- 25173116 ILS localizer equipment
- 25173118 Distance Measuring Equipment (DME)
- 25173126 Global Positioning System (GPS)
- 71122314 Multi-service vessel service
- 25173110 GNSS Wide Area Augmentation System (WAAS)
- 25173112 GPS Receiver Autonomous Integrity Monitoring
- 41115516 Decibel (dB) meter
- 41116402 Vibration and condition monitoring system
- 23201009 Pressure vessel
Show all 33
- 41106709 Plant root pressure measuring instruments
- 25173111 VHF DGNSS data link
- 25173114 Doppler Very High Frequency Omni Range (DVOR) Complete ground station
- 41112400 Pressure measuring and control instruments
- 41112401 Depth gauges
- 41112412 Pressure gauge
- 20121924 Downhole camera system
- 25173113 VOR (Doppler) and DVOR/DME systems
- 25173115 Instrument Landing System (ILS)
- 25173117 ILS glide path equipment
- 25173119 Non-directional beacon and associated equipment
- 25173120 Non-Directional Beacon (NDB)
- 25173121 Direction Finder (DF)
- 25173122 Doppler Direction Finder (DF)
- 25173124 Direction finding equipment accessories
- 25173125 VHF marker beacon and associated equipment
- 41111771 LCR meter
- 81102703 Vibration and condition monitoring service
- 41112222 Temperature gauge
- 41112223 Compound gauge
- 46171630 Vehicle rain and water level sensor
- 71122315 Diving support vessel services
- 81103010 Vessel classification services
Opportunity details come from hillsboroughcounty.bonfirehub.com. Updated .
About this opportunity
Hillsborough County is procuring four Ashcroft pressure and vacuum gauge models (Ashcroft part numbers 251009SWL02LXGV100, 251009SWL02LXGV160, 251009SWL02LXGV30IMV & 60#, and 251009SWL02LXGV60, each assembled with 50310SS02TXCK), with proposals due August 4, 2026. The County states these are the only known gauges meeting the specified operational requirements, indicating a sole-source or single-manufacturer procurement.
All four gauge models feature 2.5-inch stainless-steel dials, stainless-steel tube/process connections rated to 15,000 psi maximum pressure, glycerine-filled cases with silicone dampening, and lower-mounted process connections. The models differ in pressure range and process-connection size: 251009SWL02LXGV100 (0–100 psi, 1/4 NPT male), 251009SWL02LXGV160 (0–160 psi, 1/4 NPT male), 251009SWL02LXGV30IMV & 60# (−30 to 60 psi, 1/4 NPT male), and 251009SWL02LXGV60 (0–60 psi, 1/2 NPT male). The assembly component 50310SS02TXCK includes a 1/2 NPT female process connection, stainless-steel diaphragm material, and additional specifications that appear truncated in the source.
The source does not disclose estimated contract value, contract term, quantity, place of performance, evaluation criteria, question-due date, or pre-bid meeting details.
Opportunity text
Hillsborough County intends to procure specific Ashcroft Pressure and Vacuum Gauges as they are the only known gauges with the following specifications and operational requirements. Ashcroft Part Numbers: 1) 251009SWL02LXGV100, Assembled with 50310SS02TXCK 2) 251009SWL02LXGV160, Assembled with 50310SS02TXCK 3) 251009SWL02LXGV30IMV & 60#, Assembled with 50310SS02TXCK 4) 251009SWL02LXGV60, Assembled with 50310SS02TXCK 251009SWL02LXGV100 Specifications: • Dial Size: 2 1/2in. stainless steel • System: Stainless steel tube/process connection (max. pressure 15,000 psi) • Case Fill: Liquid filled (glycerine standard) • Process Connection Size: 1/4 NPT male • Process Connection Location: Lower • Pressure Range (psi): 0 to 100 • Dampening: Silicone filling (add to glycerine filled gauge) 251009SWL02LXGV160 Specifications: • Dial Size: 2 1/2in. stainless steel • System: Stainless steel tube/process connection (max. pressure 15,000 psi) • Case Fill: Liquid filled (glycerine standard) • Process Connection Size: 1/4 NPT male • Process Connection Location: Lower • Pressure Range (psi): 0 to 160 • Dampening: {GV} Silicone filling (add to glycerine filled gauge) 251009SWL02LXGV30IMV & 60# Specifications: • Dial Size: 2 1/2in. stainless steel • System: Stainless steel tube/process connection (max. pressure 15,000 psi) • Case Fill: Liquid filled (glycerine standard) • Process Connection Size: 1/4 NPT male • Process Connection Location: Lower • Pressure Range (psi): -30 to 60 • Dampening: Silicone filling (add to glycerine filled gauge) 251009SWL02LXGV60 Specifications: • Dial Size: 2 1/2inc. stainless steel • System: Stainless steel tube/process connection (max. Pressure 15,000 psi) • Case Fill: Liquid filled (glycerine standard) • Process Connection Size: 1/2 NPT • Process Connection Location: Lower • Pressure Range (psi): 0 to 60 • Dampening: Silicone filling (add to glycerine filled gauge) 50310SS02TXCK Specifications: • Process Connection Size: 1/2 NPT female • Diaphragm Material: Stainless steel • Bottom Housing Material: Stainless steel • Instrument Connection Size: 1/8 NPT female • Fill Fluid: Silicon 50cST Construction and Durability Requirements • All stainless steel construction for gauge and diaphragm seal • Corrosion resistant materials suitable for water and wastewater environments • All welded diaphragm seal body to prevent leakage and enhance reliability • Capable of withstanding harsh outdoor and plant conditions • Compact, lightweight assembly for tight space installations Performance and Accuracy Requirements • Gauge with shock resistant movement designed to maintain accuracy under vibration • Dampening capable of stabilizing readings in pulsating flow conditions • Matched gauge and diaphragm seal assemblies calibrated together for optimal accuracy • Suitable accuracy range for municipal water/wastewater pressure monitoring Vibration and Pulsation Handling Requirements • Gauge movement resistant to damage and drift from continuous vibration • Built in dampening options that mitigate pulsation effects caused by pumps, ARVs, and lift station operations • Ability to provide stable readings even under dynamic system conditions Media Protection Requirements • Diaphragm seal providing full isolation between the process media and gauge internals • Resistant to corrosive liquids and chemical additives commonly found in wastewater • Ability to prevent plugging from solids or debris • Freeze resistant design to mitigate temperature related damage • Zero leak path design to avoid product retention and ensure proper seal function Environmental Compatibility Requirements • Compatibility with wastewater, potable water, reclaimed water, and chemical feed systems • Resistance to temperature variations typical of lift stations, ARVs, and treatment plant environments • Suitable for indoor, outdoor, above grade, and below grade installations Calibration Requirements • Calibration performed by a qualified seal assembler • Calibration certification included with each unit • Post installation technical support available from manufacturer authorized personnel Operational Capability Requirements • Ability to continuously monitor pressure or vacuum at lift stations, air release valves, and treatment plant systems • Instrumentation capable of detecting abnormal pressure conditions to prevent blow offs, SSOs, and equipment failures • Support for both horizontal and vertical piping configurations Public Health and Safety Requirements • Instruments must support prevention of sanitary sewer overflows • Must mitigate risk of catastrophic failures that can lead to environmental contamination • Must provide reliable data necessary for regulatory compliance and safe operation of critical public infrastructure Compatibility Requirements • Full compatibility with existing municipal pressure monitoring programs and system pressure ranges • Suitable for use with standard process connections used at lift stations, ARVs, and treatment plants • Compatible with commonly used fill fluids for diaphragm seals in water/wastewater applications This notice of intent is not a request for competitive proposals/bids. Contractors who are able and interested in providing all the identified parts must submit clear and convincing information to support a challenge to the intended award. Challenges to this procurement must be received no later than the specified Close Date of this Special notice and must be submitted using the "submission" section in EUNA Procurement for this particular procurement. Absent any challenges, an award will likely be made after the Close Date. The County will review properly submitted challenges (responses) to determine whether bona fide competition exists. Any such responses received by the deadline will be evaluated solely for the purpose of determining whether to conduct this procurement as a competitive solicitation.