This pre-solicitation notice seeks a contractor to install a liner into an existing steam condensate pipe at the Alexandria VA Health Care System in Pineville, Louisiana. The contractor will be required to locate and expose the condensate line, remove a section and install a new expansion loop with welded flanges, shoot two glass liners from opposite ends to meet in the center, provide steel plating for future access, backfill to grade, and provide warranties of at least ten years for the liner and two years for the installation work. Responses are due by October 24, 2023 at 3:00 PM Central Time and shall be submitted via email to james.rasco@va.gov.
This requirement has a set-aside designation for Service-Disabled Veteran-Owned Small Businesses. The work is covered under NAICS code 238220 for plumbing, heating, and air conditioning contractors. No incumbent is named and no budget or value is provided. Respondents must be able to complete the installation safely, efficiently, and as addressed in the scope of work.
Notice text
Request for Information- Sources SOUGHT
Contractor shall furnish all Services to support and provide the following:
The Alexandria VA Health Care System, Pineville, LA has a requirement that involves installing a liner into an existing steam condensate pipe. The integrity of the pipe has corroded, providing numerous condensate leaks leading to an increase in makeup water needed at the boiler plant.
The North American Industry Classification (NAICS) code for this potential acquisition is The NAICS code is 238220 Plumbing, Heating and Air Conditioning with a size standard of $19 M. This solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular (FAC) 2023-07. Only emailed requests received directly from the requester will be accepted. The response date to this bid request notice is Oct 24, 2023, at 15:00 PM Central Time. Hard copy submissions are not acceptable. The Government will not pay any costs for responses submitted. Electronic submissions are acceptable and may be directed to james.rasco@va.gov. All inquiries regarding this request should be directed to the same email address. NO ADDITIONAL INFORMATION IS AVAILABLE OTHER THAN WHAT IS NOTED HEREIN. CONCERNS ARE REQUESTED NOT TO CALL THE INDIVIDUAL VAHCS, REQUESTING MORE INFORMATION.
REQUIREMENT:
Background:
Alexandria VAHCS has a requirement that involves installing a liner into an existing steam condensate pipe. The integrity of the pipe has corroded, providing numerous condensate leaks leading to an increase in make up water needed at the boiler plant.
Objective:
Award a firm-fixed price contract to a contractor capable of performing installation of liner in existing 2-1/2 condensate line safely, efficiently, and in the manner addressed by the scope of work
Scope of Work:
Locate middle of expansion loop by means of digging, chip concrete to expose condensate line
Remove 2 ½ from expansion loop, provide certified welder to weld flanges on pipe in ground and new 2 ½ SCH 80 steel expansion loop
Provide 2 glass liners to shoot, both will be shot from opposite ends of pipe toward middle to meet in center
Provide ¼ steel plate to place on concrete tunnel for future access
Backfill to existing grade
Glass liner to be rated to withstand temperatures up to 350 degrees
Provide warranty of no less than 10 years for liner
Provide warranty of no less than 2 years on work performed
Location:
Work is to be performed on the Alexandria VA campus
Files
| File | Type | Posted |
|---|---|---|
| 36C25624Q0027.docx | DOCX document |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| J048--NEW - Energy Center Steam Header& Boilers valves, gaskets, and vent replacement | Veterans Integrated Service Network 17 | Service-Disabled Veteran-Owned Small Business | |
| Z2NZ--Turn Key Chiller Equipment (Purchase and Install) | Veterans Integrated Service Network 16 | Service-Disabled Veteran-Owned Small Business | |
| N048-- B41 Isolation Valve Installation | Veterans Integrated Service Network 16 | Service-Disabled Veteran-Owned Small Business | |
| Z2DA--FY27 NRM 558-24-160, Domestic Water, Chilled Water and Steam Piping (VA-26-00066009) | Veterans Integrated Service Network 6 | Service-Disabled Veteran-Owned Small Business | |
| J043--Damen Building Vacuum Condensate System Rebuild | Veterans Integrated Service Network 12 | No set-aside |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity