Z2DZ--10-B Asbestos Removal and Fire Damper Repair

Closed Pre-Solicitation Posted

Solicitation number
36C24624Q0909
Agency
Responses due
Set-aside
No set-aside

Opportunity facts

Place of performance
Durham VA Medical Center 508 Fulton Street Durham North Carolina 27705 U.S.A.

Notice details come from SAM.gov. Updated .

About this opportunity

Paragraph 1:

The Department of Veterans Affairs, Network Contracting Office 6, is conducting market research to identify potential sources for the repair, replacement, and inspection of fire and smoke dampers, as well as asbestos removal, at the Durham VA Medical Center in North Carolina. The scope of work includes removing and replacing 4 failed fire dampers, increasing access to 4 additional fire dampers, and providing all necessary restoration work. The contractor will be responsible for furnishing labor, materials, and certified inspectors to complete the project within a 180-calendar day period of performance. Interested parties are requested to provide capabilities statements, compliance with subcontracting limitations, timelines, and other relevant information by June 13, 2024 at 11:00 AM EDT.

Paragraph 2:

This procurement does not have a set-aside designation, and the Government will review responses from all businesses, including large firms, to determine if a set-aside is appropriate. The anticipated magnitude of construction for this project is between $25,000 and $100,000, subject to revision prior to the release of a solicitation. The NAICS code is 236220 (Commercial and Institutional Building Construction) and the Product/Service Code is Z2DZ (Repair or Alteration of Other Hospital Buildings).

Notice text

Page 3 of 3

DEPARTMENT OF VETERANS AFFAIRS

Network Contracting Office 6 (NCO 6)

Sources Sought 36C24624Q0909:

OVERVIEW

The Department of Veterans Affairs, Network Contracting Office 6 is conducting market research to identify potential sources for services to complete the below scope of work. The place of performance will be the hospital campus of the Durham VA Medical Center in Durham, North Carolina. Forward all questions to the point of contact identified below. This is not a pre-solicitation notice, but the magnitude of construction for this project is currently between $25,000 and $100,000 but is subject to revision prior to release of a solicitation.

Period of Performance: 180 calendar days from receipt of Notice to Proceed (NTP).

SCOPE OF WORK

The contractor shall furnish all labor, material, tools, supervision, quality control, and certified inspectors necessary to repair, replace, increase access to, inspect and certify the fire and smoke dampers identified in the Scope of Work below.

The contractor shall be responsible for all demolition work to gain access to the broken fire dampers.

The contractor shall be responsible for the asbestos removal and inspections.

The contractor shall remove all construction debris they generate from the hospital and maintain a neat and tidy work area daily.

The contractor shall remove four (4) failed fire dampers and replace with new UL555 rated fire dampers to match existing fire rating.

Upon completion of damper replacement, the contractor shall be responsible for all restoration work to the area. The restoration work shall match in uniformity and quality to that of the original existing construction.

The contractor shall inspect and provide documentation of the new fire damper functionality.

List of dampers needing replacement. The location on the drawings indicated (in parenthesis).

FD-10B-1B-06 (10B-1)

FD-10B-2B-007 (10B-2)

FD-10-5B-04 (10B-4)

FD-10-3B-08 (10B-3)

The contractor shall increase access to four (4) fire dampers.

The contractor shall be responsible for providing and installing new access doors or replacing smaller access doors with a minimum of 24 x24 doors in ductwork as needed to allow a technician to reach the fire damper for inspection.

The contractor shall relocate any infrastructure, utilities, or obstructions necessary for access to the fire damper access doors including but not limited to electrical conduit, sprinkler pipe, HVAC and domestic water piping, medical gases, fire alarm, and communications cable.

The contractor shall inspect and provide documentation of fire damper functionality.

The contractor shall provide a written safety plan to the COR for approval prior to the commencement of work. This plan shall describe the contractor s general safety program and shall identify specific safety hazards incidental to the contract work.

The contractor shall secure and follow all instructions of an Infection Control Risk Assessment (ICRA) for any work behind walls or above ceilings.

The contractor shall submit a work schedule and submittals within 14 days of notice to proceed.

The Durham VAHCS shall have 20 workdays to review and approve submittals and outage requests.

The contractor shall conduct all work in accordance with applicable building codes and the VA Specifications.

The contractor shall be responsible for providing their own access to building codes.

SMALL BUSINESS REQUIREMENTS

For market research purposes, all responses to this notice will be reviewed, regardless of small business/socioeconomic category, including those firms that are identified as large businesses. Review of responses to this notice will support later determination of set-aside requirements, if a solicitation becomes available, where the rule of two is met regarding a set-aside, including set-asides under 38 U.S.C. 8127 and 8128 for SDVOSB and/or VOSB firms registered in the VIP database, in accordance with priorities set by regulation.

NAICS CODE: 236220 Commercial and Institutional Building Construction (SBA Size Standard: $45.0 million annual revenue)

PRODUCT OR SERVICE CODE (PSC): Z2DZ, Repair or Alteration of Other Hospital Buildings

THIS IS A SOURCES SOUGHT NOTICE ONLY. This notice does NOT constitute as a request for proposal, request for quote, or invitation for bid. No formal solicitation document exists at this time. We are seeking information for market research purposes only. The Government will not pay for any information solicited.

INSTRUCTIONS FOR RESPONDING:

All interested parties should respond, in writing via email to Alice.Custis@va.gov. No telephone inquiries will be accepted. Your response is required by 11:00 AM EDT on Thursday, June 13, 2024. In your response, please include the following:

Company name

Address

Point of contact with email and phone number

SAM Unique Entry ID number and evidence of current SAM registration (see https://www.sam.gov for more information)

Company Socio-Economic SIZE (example large, small, SDVOSB, VOSB, WOSB etc.)

Proposed NAICS code (if different from above)

Capabilities statement, to include experience with contracts of similar scope and magnitude.

Information describing your interest.

A brief statement on how you will comply with the Limitations on Subcontracting, if applicable

In addition to this information, please include responses to all of the following in your submission:

What additional information would you require in order to provide a quote for this project?

Approximately how long would it take to complete the project, including lead times for materials?

Is our chosen NAICS code of 236220 the best fit for this project?

Is our chosen PSC code of Z2DZ the best fit for this project?

Is our anticipated Magnitude of Construction appropriate for this project?

Use of equipment and tools that transmit vibrations and noises through the building structure, are not permitted in buildings that are occupied jointly by patients or medical personnel, and Contractor s personnel, except as permitted by COR where required by limited working space. Provide information on types of tools necessary for accomplishing scope of work.

Please provide comments on ability to hold bid prices for 120 days after submission.

Please provide any comments that may increase your level of interest and will assist us with developing the solicitation for this project.

POINT OF CONTACT:

Alice Custis, PMP, LEED AP, CSM

Contract Specialist, Construction Team 1

Network Contracting Office 6 (NCO 6)

100 Emancipation Dr.

Hampton, Virginia 23667

Alice.Custis@va.gov

DUE DATE FOR RESPONSES:

This notice will close on Thursday, June 13, 2024, at 11:00 AM Eastern Time.

Files

File Type Posted
36C24624Q0909.docx DOCX document

Similar open opportunities

Opportunity Agency Set-aside Responses due
Z2DA--FY27 NRM 558-24-160, Domestic Water, Chilled Water and Steam Piping (VA-26-00066009) Veterans Affiars Medical Center Durham NC 27705 · NAICS 236220 Veterans Integrated Service Network 6 Service-Disabled Veteran-Owned Small Business
Z2DA--FY27 NRM 558-24-160, Domestic Water, Chilled Water and Steam Piping (VA-26-00066009) Durham, North Carolina 27705, United States · NAICS 236220 Veterans Integrated Service Network 6 Service-Disabled Veteran-Owned Small Business
J012--FIRE DAMPER REPAIR SERVICES VA Central California Healthcare System VA Central California Healthcare System 2615 E Clinton Avenue Fresno CA 93703 · NAICS 811310 Veterans Integrated Service Network 21 No set-aside
Z1DA--Sources Sought Notice/Market Research Project: Renovate SPS Phase 3 Central Virginia VA Healthcare System Cvhcs Richmond Virginia 23249 · NAICS 236220 Veterans Integrated Service Network 6 No set-aside
F108--620-26-206 Asbestos Abatement NAICS 562910 Veterans Integrated Service Network 2 No set-aside

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors