Z2DA--Monitoring for Legionella, 589A7-22-204
Closed Solicitation Posted
- Solicitation number
- 36C25523R0082
- Agency
-
Veterans Integrated Service Network 15
Veterans Health Administration, Department of Veterans Affairs
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 238220 Plumbing, Heating, and Air-Conditioning Contractors
Notice details come from SAM.gov. Updated .
About this opportunity
This solicitation seeks proposals to install continuous water monitoring systems at multiple buildings of the Robert J. Dole VA Medical Center in Wichita, Kansas. The Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 15 will award a firm-fixed price contract for a 180-day period of performance to test and monitor the water systems for Legionella bacteria. Proposals are due May 5, 2023 and will be evaluated using the Lowest Price Technically Acceptable source selection process. Offerors must have experience providing similar monitoring services and documentation of past performance, technical qualifications, staff resumes, and a safety plan.
There is no set-aside for this opportunity. The work includes continuous monitoring of water pressure, temperature, pH, hardness, and biocide levels at two locations, as well as temperature and biocide residual monitoring at approximately eight additional locations across three buildings at the Wichita VA Medical Center facility located at 5500 East Kellogg Drive in Wichita, Kansas. The contract value is estimated between $500,000 and $1,000,000 to install monitoring systems from an Emmerson Rosemount MCL water monitoring station integrated into the building automation system.
Notice text
3 versions
Update #3 · Latest ·
Amendment A0001 to Solicitation 36C25523R0082 Install Continuous Monitoring for Legionella Project 589A7-2-204
Update #2 ·
Scope of Work
This project will install a continuous water monitoring system for Buildings 1 (Main Hospital), 59 (Substance Abuse Residential Treatment Facility – SARRTF), and 60 (Community Living Center – CLC) in accordance with VHA Directive 1061. The scope will include the following items:
1. The continuous monitoring system will meet the requirements located in VHA Directive 1061, chapter 3 paragraphs j., Appendix A 2.a., 2.b.(3), and 2.c.(2)(a). The system will integrate with and use the existing Building Automated System to display and record data. The system will be able to trend data and alert when values are outside of acceptable limits. The system and the data will be owned by the VA and will not require a subscription or service contract.
2. Incoming water will be monitored at two locations. Continuous monitoring of incoming water will include water pressure, temperature, pH, hardness, suspended or dissolved solids, and biocide levels (monochloramine).
a. Building 1: Domestic cold water entering building 1 room 019-1.
b. Building 60: Domestic cold water entering building 60 in room 102B-60.
i. A new hub drain will be needed to channel the water out since there is no drain nearby.
3. Temperature and biocide residual (monochloramine) will be monitored at approximately 8 locations.
a. Building 1: Hot water recirculation in the basement mechanical room and the domestic cold water and hot water loops on fourth floor east and west.
b. Building 59: Domestic cold water and hot water in room 139-59.
c. Building 60: Domestic cold water, hot water, and hot water recirculation loops in attic.
4. The basis of design for water monitoring will be an Emmerson Rosemount MCL water monitoring station. They will be in accessible locations at the areas indicated on the project drawings. The unit shall be connected to the BAS for monitoring via 4-20 cable.
5. Architectural scope is limited to patch and repair or walls, ceilings, and finishes as required to address the demolition of plumbing items.
Update #1 ·
Description
Files
| File | Type | Posted |
|---|---|---|
| 589A7-22-204 Sign In Sheet signed.pdf | ||
| 36C25523R0082 0001.docx | DOCX document | |
| 36C25523R0082_1.docx | DOCX document | |
| 589A7-22-204 Const Bid Drawings.pdf | ||
| 589A7-22-204 Bid Specs Full Set.pdf | ||
| 589A7-22-204 SOW.pdf |
Notice history
| Notice | Type | Posted |
|---|---|---|
| This notice | Solicitation | |
| Z2DA--Monitoring for Legionella, 589A7-22-204 | Pre-Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Z2DA--657-27-111JB, Install Continuous Water Monitoring System, JB- STL | Veterans Integrated Service Network 15 | Service-Disabled Veteran-Owned Small Business | |
| H346--Legionella Water Testing | Veterans Integrated Service Network 22 | Service-Disabled Veteran-Owned Small Business | |
| Z1DA--CON-NRM-668-22-106 Correct Domestic Water System | Veterans Integrated Service Network 20 | No set-aside | |
| F109--Water Management Program and Chemical Testing Amendment 001- Q&A | Veterans Integrated Service Network 1 | Service-Disabled Veteran-Owned Small Business | |
| F103--D and D laboratory steam & water testing | Veterans Integrated Service Network 6 | No set-aside |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity