Z1DA--512-24-122 Structural Steel Fireproofing (VA-24-00093106) FY25 Requirement
Closed Solicitation Posted
This opportunity was awarded. See the award notice from .
- Solicitation number
- 36C24524B0022
- Agency
-
Veterans Integrated Service Network 5
Veterans Health Administration, Department of Veterans Affairs
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 236220 Commercial and Institutional Building Construction
- Points of contact
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of Veterans Affairs (VA) Veterans Health Administration, Veterans Integrated Service Network 5 is seeking contractors to provide structural steel fireproofing services at the VA Maryland Health Care System's Baltimore campus. The work will involve applying approved fireproofing material to exposed structural beams throughout the facility, including in interstitial spaces and service bays. The contract will be awarded on a firm-fixed-price basis, with a 365-calendar day performance period. Bids must be submitted electronically by 2:00 PM EST on November 6, 2024, and will be evaluated solely on bid price and price-related factors.
This is a 100% Service-Disabled Veteran-Owned Small Business (SDVOSB) set-aside opportunity with a NAICS code of 236220 and a size standard of $45 million. The magnitude of construction is estimated at $500,000 to $1,000,000. Bidders must be listed in the VetCert database to be eligible for award. The VA has provided various project documents, including technical memoranda, specifications, drawings, and an Infection Control Risk Assessment template, to assist offerors in understanding the requirements.
Notice text
2 versions
Update #2 · Latest ·
RFIs Received October 17, 2024
VA Response Sent October 22, 2024, by Mikaela Kaufman
SOW 1C states "See specifications and all other drawings for additional details." There were no specifications or drawings included for this project. Based on the information provided, there is no way for the contractor to accurately determine the size of the columns and beams which is necessary to accurately quantify the amount of fireproofing needed.
Question: Are there existing as-built drawings that could be provided?
The existing drawings available for reference of the beams/columns within the hospital's spaces are the original framing plans. They're available and will be provided.
In order to accurately understand the amount of fireproofing needed, we need to understand the size of the beams and columns to be fireproofed.
Question: If as-builts will not be provided, can the sizes of the exposed columns and beams to be fireproofed be provided?
The beam type and length of the beams are noted within the framing plans provided.
SOW 1C states "See specifications and all other drawings for additional details." SOW 2A, 2B, and 2C reference permits, submittals, and subcontractor POCs and certifications and all state "See specs for more details." The VA has said references to drawings and specifications were meant to reference the Technical Memorandum, but that does not include the referenced information.
Question: Will specifications be provided for this project? Specifically, we are seeking requirements for general conditions, ICRA, and fireproofing.
Yes, specifications and condition requirements will be provided for this project.
SOW 4A states "Exposed steel in any areas not accessible in section 2.1 of the "Technical Memorandum Balt VAMC Steel Fireproofing" document shall be fireproofed. There are 3 areas in the technical memorandum that state "could not access this area." There is no way for the contractor to quantify the work in these areas based on the information provided.
Question: Can allowances or assumed quantities be provided for these areas?
Any assumptions that are be made must be done by referencing the site drawings that are being provided.
The ECS report lists various areas with exposed columns and beams. These spaces are delineated by floor & by quad. For example, there are beams listed in Quads A, B, C & D for the interstitial spaces between floors 1 & 2.
Question: Will all quads (A, B, C, & D) be accessible through the same door for that floor or will each Quad have its own access door?
Each quadrant of the VA has its own access doors into the interstitial spaces located within the stairwells. Access to different quads within the interstitial site is dependent on the internal conditions of said interstitial space (for example, passage between one quadrant to another within a floor s interstitial space might not be possible due to the structure of the HVAC and/or plumbing fixtures within the space).
There are many different areas listed in the ECS report, but no way to determine how many points of entry there will be to access these spaces.
Question: Considering that ICRA measures will need to be provided at each entry point to protect the hospital s occupants, can the VA provide the total quantity of entries that will require ICRA measures?
All entries that are to be used by the contractors will need to be protected to the satisfaction of the ICRA requirements. Referencing the attached ICRA, the main concerns involving this project are keeping dust from travelling out of the interstitial spaces with contractor movement and maintaining a clean environment after the completion of the work. There are no requirements for ICRA barriers or negative pressure.
Update #1 ·
Structural Steel Fireproofing
Files
| File | Type | Posted |
|---|---|---|
| 02 Combined Specs 512-24-122.pdf | ||
| Structural Floor and Interstitial Framing Drawings Part 2.pdf | ||
| Structural Floor and Interstitial Framing Drawings Part 1.pdf | ||
| 09 ICRA Structural Steel Fireproofing.docx | DOCX document | |
| 36C24524B0022 0001.docx | DOCX document | |
| RFI Form.xlsx | XLSX spreadsheet | |
| 36C24524B0022_1.docx | DOCX document | |
| Technical Memorandum_Balt VAMC Steel Fire Proofing FOR IFB.pdf |
Notice history
| Notice | Type | Posted |
|---|---|---|
| Z1DA--512-24-122 Structural Steel Fireproofing (VA-24-00093106) FY25 Requirement | Award Notice | |
| This notice | Solicitation | |
| Z1DA--512-24-122 Structural Steel Fireproofing (VA-24-00093106) FY25 Requirement | Pre-Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Y1DA--Project620-22-110 Replace and Upgrade Fire alarm System at Montrose VAMC | Veterans Integrated Service Network 2 | Service-Disabled Veteran-Owned Small Business | |
| Z2DA--FY27 NRM 558-24-160, Domestic Water, Chilled Water and Steam Piping (VA-26-00066009) | Veterans Integrated Service Network 6 | Service-Disabled Veteran-Owned Small Business | |
| Z1DA--542-21-113 | Correct FCA Deficiencies – Repair Water Penetration | NCO 4 Construction East (VA-26-00020634) (VA-26-00020634) | Veterans Integrated Service Network 4 | Service-Disabled Veteran-Owned Small Business | |
| Z1DA-- 460-26-004 | Wilmington VAMC Roof Replacement | NCO 4 Construction East (VA-26-00029152) | Veterans Integrated Service Network 4 | Service-Disabled Veteran-Owned Small Business | |
| Annual Inventory and Inspection of Fire and Smoke Doors | Veterans Integrated Service Network 17 | Service-Disabled Veteran-Owned Small Business |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity