XTLF 15-1018 Repair AA and E Storage at F527
Award Notice Posted
- Solicitation number
- FA3029-0003
- Agency
-
Air Education and Training Command
Air Force, Department of Defense
- Awarded
- to Waldrop Construction Inc.
- Set-aside
- Total Small Business
Opportunity facts
- Contract number
- FA302925C0005 Federal contract award
- NAICS code
- 236220 Commercial and Institutional Building Construction
- Place of performance
- Enid, Oklahoma 73705, United States
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of the Air Force Air Education and Training Command awarded contract FA302925C0005 to WALDROP CONSTRUCTION INC for $437,129.23 on September 24, 2025, for the renovation of building 527 at Vance Air Force Base to create compliant ammunition and explosives (AA&E) storage facilities. The project involves reinforcing the existing AA&E storage room by adding steel and plywood layers to interior walls and ceiling, replacing the entry door with a compliant version, installing tamper-resistant window fasteners, and relocating electrical circuits to improve emergency personnel access. The renovations are required to meet UFC 04-026-01 and MIL-HNDBK 1013/1A standards, ensuring the facility can provide minimum 10-minute forced entry resistance against threat severity level III for storing AA&E Risk Categories II through IV. This work was designated as a total small business set-aside and addresses safety compliance issues that would pose potential risks to the base if left unresolved.
Notice text
This service will renovate building 527 to comply with UFC 04-026-01 and MIL-HNDBK 1013/1A. The building requires minor
renovations to eliminate deviation request VANCE AFB 97-01. The scope of this work includes the reinforcement of the existing
AA&E storage room by adding steel and plywood layers to surrounding interior walls and ceiling. Existing fixtures will be
removed and reinstalled on the new wall and ceiling faces. Entry door will be replaced with a compliant door, and window
fasteners will be replaced with compliant tamper-resistant fasteners. Circuits on the interior electrical panel dedicated to other
areas of the facility will be relocated to a new panel outside the room, providing better access to emergency personnel. AA&E
Risk Categories II through IV must be stored in a structure with a minimum forced entry resistance of 10 minutes against threat
severity level III. If facility does not receive renovation, the building will not meet UFC and MIL-HNDBK code and remain
potential risk of safety to the base.
Awarded contract FA302925C0005 to WALDROP CONSTRUCTION INC for 437129.23 on 2025-09-24.