X-Ray Maintenance and Repair - 105MM Artillery Renovation Line
Award Notice Posted
- Solicitation number
- W52P1J-16-T-3014
- Agency
-
Joint Munitions Command
Army Materiel Command, Department of Defense
- Awarded
- to V.j. Technologies, Inc.
- Set-aside
- Total Small Business
Opportunity facts
- Contract number
- W52P1J16P3035 Federal contract award
- NAICS code
- 811219 Other Electronic and Precision Equipment Repair and Maintenance
- PSC
- Not on record
- Place of performance
- Blue Grass Army Depot 431 Battlefield Memorial Highway Building 555 Richmond, Kentucky 40475, United States
Notice details come from SAM.gov. Updated .
Notice text
North American Industry Classification System (NAICS) Code 811219, Other Electronic and Precision Equipment Repair and Maintenance.
The Army Contracting Command - Rock Island intends to award a one-year with two option years' requirements for a Firm Fixed Price (FFP) Lowest Price Technically Acceptable (LPTA) 100% Total Small Business Set Aside Contract with the following parameters for unlimited technical support via phone/remote access, preventive maintenance, and repair for of the Varian Linatron Linear Accelerator, Base Center Line, and Temperature Control Unit.
Vendor shall be proficient on the Varian Linatron Linear Accelerator, Base Center Line, and Temperature Control Unit and have a business agreement with Varian the manufacture of this equipment to perform warranty repairs and replacement of parts.
Vendor must have certifications, technical skills, training, and previous experience with the Varian Equipment listed in order to perform preventive maintenance, repair, and service. Vendor will provide unlimited hours technical support via help desk, and have remote access capabilities.
Vendor must be able to send a qualified technician to Blue Grass Army Depot within 24 hours to resolve the issue if issue cannot be resolved via help desk and remote access.
Vendor must provide all the required hardware, software, materials, tooling, rigging, and supplies to work and perform maintenance and repair on the Varian Linatron Linear Accelerator, Base Center Line, and Temperature Control Unit.
Services to be performed on the Linatron will be troubleshooting and repair of the Varian Linatron Linear Accelerator, Base Center Line, and Temperature Control Unit as required. This type of service is considered enduring, special technical skills, training, and experience needed in order to perform these requirements.
Vendor must be familiar with the 105MM Artillery Renovation Procedures as the Varian Equipment is used in the renovation line of 105MM Artillery Rounds.
Technicians must be capable of obtaining successful background check to perform work in a restricted area of the Blue Grass Army Depot.
This notice of intent is not a request for competitive proposals. A formal solicitation document is not available. No award will be made on the basis of offers received in response to this notice. Interested parties shall identify their interest in writing and must include prices and descriptions containing sufficient technical documentation to establish capability to meet the requirements. Any firms believing that they can provide the services may submit a written response to be received by the Contracting Officer by 24 November 2016 by 5pm Central Standard Time. All responsible sources shall submit responses in writing to: Army Contracting Command - Rock Island ATTN: CCRC-ID/Nathan Tutor, 1 Rock Island Arsenal, IL 61299-8000 or via email to nathanial.tutor.civ@mail.mil.
On GovTribe