The Air Force Materiel Command Test Center is issuing a Request for Information on an X-Ray Inspection System, with responses due July 27, 2026. This is an RFI for planning purposes only and does not constitute a commitment to contract or issue a future solicitation; the Government will not evaluate responses as proposals or accept unsolicited quotes, and all response costs are the responsibility of the respondent.

The SIDEC Lab at Edwards Air Force Base requires an X-Ray machine meeting the following critical specifications: minimum focal spot size of 5 micrometers or less to support 0.5 millimeter pitch components, minimum tube voltage of 90 kilovolts to support standard 0.063-inch board thickness, capability to support printed circuit board assemblies of at least 10 inches by 12 inches, and operation on standard 115 VAC at 60 hertz. Respondents should clearly mark proprietary information in their submissions.

Notice text

THIS NOTICE IS A REQUEST FOR INFORMATION ONLY. The RFI is issued solely for information and planning purposed – it does not constitute as a Request for Quote (RFQ) or a promise to issue a RFQ in the future. This RFI does not commit the Government to contract for any supply or service whatsoever. Responses will be treated as information only and will not be evaluated as a proposal. Further, the Government is not at this time seeking quotes and will not accept unsolicited quotes. A return response from the Government regarding the RFI submission is not guaranteed. The RFI respondents are advised that the Government will not pay for any information or administrative costs incurred in response to this RFI; all costs associated with responding to this RFI will be solely at the interested party’s expense. Not responding to this RFI does not preclude participation from future announcements or contracts. Respondents should indicate which portions of their response are propriety and should mark accordingly.

NOTE: This RFI is not associated with any previous or ongoing RFQs or Fair Opportunity Proposal Requests issued by the DAF.

The SIDEC Lab at Edwards AFB has a requirement for a X-Ray Machine with the salient characteristics as follows:

The critical specifications that our X-Ray system must meet are as follows:

  • Minimum focal spot size of 5um or less (to support our expected 0.5mm pitch components)
  • Minimum tube voltage: 90 kV (to support our standard 0.063” board thickness)
  • Must support PCB assemblies at least 10”x12”
  • Operates on standard 115VAC @ 60Hz (<14A)
  • Must have a footprint of 36”x36” or smaller, with a maximum height of 48” while being moved, 60” while stationary.
  • Must weight 900 lbs. or less (our workbench capacity)
  • Must not require any external X-ray radiation related safety precautions (must have safety interlocks)
  • Must be a fully functional stand-alone system (no other equipment required to produce PCB inspection images/models)
    • Must include a Microsoft Windows-based PC for control, image preview, and data export.
    • Must include hardware/software for creating Computed Tomography (CT) visualizations (3D models)
  • Basic installation, setup, and training must be included.

Notice history

Notice Type Posted
X-Ray Inspection System Latest solicitation Solicitation
This notice Original Pre-Solicitation

Similar open opportunities

Opportunity Agency Set-aside Responses due
Computed Topography (CT) X-Ray Cabinet Sources Sought San Diego, California, United States · NAICS 334517 Naval Air Systems Command No set-aside
X-Ray Computed Tomography Cabinet System (Revised Requirements) Patuxent River, Maryland 20670, United States · NAICS 334516 Naval Air Systems Command No set-aside
Neutron Radiography (N-Ray) Capacity NAICS 541380 AFLCMC Hill AFB No set-aside
Custom CdZnTe X-Ray and Gamma-Ray Detector Prototype for Beta-Gamma Radioxenon Education and Research. Wright Patterson AFB, Ohio 45433, United States · NAICS 334516 AFLCMC Wright Patterson AFB No set-aside
Computed Tomography (CT) Scanner System Columbus, Ohio, United States · NAICS 334516 Defense Logistics Agency Total Small Business

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors