WHS/BPO Design, Construction, & Physical Security Analytical Support
Award Notice Posted
- Solicitation number
- HQ0034-12-R-3012
- Agency
-
Washington Headquarters Service
Department of Defense
- Awarded
- to Gilbane Building Company
- Set-aside
- No set-aside
Opportunity facts
- Contract number
- GS-23F-0024R|HQ0034-12-F-0273 Federal contract award
- NAICS code
- 541618 Other Management Consulting Services
- PSC
- Not on record
- Place of performance
- 4800 Mark Center Drive, STE 08G05 Alexandria, Virginia 22350, United States
Notice details come from SAM.gov. Updated .
Notice text
To provide non-personal services necessary to perform the following:
The objective of this requirement is for a follow-on effort of the Design, Construction, & Physical Security
Analytical Support for the BRAC Program Office (BPO). The support program provides an in-depth analysis of the
technical remediation and modification requirements to efficiently and effectively enhance the protection of
Department of Defense (DOD) assets and security interests within the Fort Belvoir Mark Center Campus facility.
The support program is also responsible for validating the planning, design and construction management services
administered by the United States Army Corps of Engineers (USACE) to ensure all operational, physical security
and life safety requirements are executed, as required by the BRAC 133 contractual obligations. The responsibilities
of the support program includes, but is not limited to: requirements gathering; program planning; design, cost and
schedule analysis; deficiency reports; coordination with building tenants for access into restricted areas; and other
support activities as the building owners' representative.
The Mark Center was designed and constructed for WHS under a contract awarded and administered by USACE.
Since tenant occupancy and use of the Fort Belvoir Mark Center Campus facility, it has become apparent that
several operational requirements were not identified or anticipated during the initial design phase. This included the
need for dedicated access to telecommunication rooms (TRs) and electrical rooms (ERs), and the application of
Americans with Disabilities Act (ADA)-compliant door closures on access/egress to tenant spaces. Additionally,
construction of the framing and surrounding walls for the physical security-compliant doors, the fire egress doors,
and the exterior entry & egress doors have been found to be inadequate to support the required physical security
hardware and door specifications. Substantial latent defects must be addressed. Thus, an unplanned remediation
project to address the structural and physical security failures is required to ensure physical security and life safety
standards for entry and egress are maintained, and that the security of classified spaces is not compromised. All
three activities will ensure classified infrastructure protection, enhance force protection, and life-safety egress
requirements are met. USACE is primarily responsible for designing and implementing the changes necessary to
enhance physical security at the Mark Center.
The support program under this requirement will continue to provide WHS security oversight management on behalf
of the tenant security managers for any physical construction in secure spaces and oversight of all other construction
to ensure physical security requirements are achieved. By providing oversight management support, the program
will ensure that the design intent of operational flexibility within the Mark Center Building is achieved, by allowing
for easy accreditation or certification of non-secure space at any time in the future.