Valves
Awarded Award Notice Posted
- Solicitation number
- SPE7MX15R0134
- Agency
- Land and Maritime Defense Logistics Agency, Department of Defense
- Awarded
- to Westfield Hydraulics Inc.
- Set-aside
- No set-aside
Opportunity facts
- Contract number
- SPE7MX16D0069 Federal IDV award
- NAICS code
- 332911 Industrial Valve Manufacturing
- PSC
- Not on record
Notice details come from SAM.gov. Updated .
Notice text
Added: Sep 10, 2015 9:28 am
This posting is for 8 NSN(s)
4810006887866 VALVE,SOLENOID
4810006899920 VALVE,SOLENOID
4810007797550 VALVE,SOLENOID
4810007888391 VALVE,SOLENOID
4810010126086 VALVE,SOLENOID
4810011164869 VALVE,SOLENOID
2910011315719 VALVE ASEMBLY,FUEL
4820011898270 VALVE,PURGE
___________________________________________________________________
NSN:006887866
VALVE, SOLENOID
STAINLESS STEEL BODY AND TRIM.
24VDC RATING. MAXIMUM OPERATING PRESSURE 350 PSI
TEMPERATURE RATING 130 DEGREES F.. NORMALLY
CLOSED. 1/8 INCH THREADED EXTERNAL TUBE ENDS.
WHITE VINYL TUBING REQUIRED.
REFERENCE NUMBER:CS187
REFERENCE NUMBER:CA061
WESTFIELD HYDRAULICS INC DBA 53730 P/N 550310
VALCOR ENGINEERING CORP DBA 96487 P/N V27200-527
PREP FOR DELIVERY
LINE ITEM 00001 TYPE OF COVERAGE: DLA DIRECT, CONUS
PKGING DATA-QUP:001
SHALL BE PACKAGED STANDARD COMMERCIAL IN ACCORDANCE WITH ASTM D 3951.
NSN:006899920
VALVE, SOLENOID, ALUMINUM BODY. NORMALLY CLOSED.
REFERENCE NUMBER:CS072
REFERENCE NUMBER:CA061
CRITICAL APPLICATION ITEM
WESTFIELD HYDRAULICS INC DBA 53730 P/N 550110
VALCOR ENGINEERING CORP DBA 96487 P/N V5000-41
HONEYWELL INTERNATIONAL INC. DBA 99193 P/N 692545-2
PREP FOR DELIVERY
LINE ITEM 00002 TYPE OF COVERAGE: DLA DIRECT, CONUS
PKGING DATA-QUP:001
SHALL BE PACKAGED STANDARD COMMERCIAL IN ACCORDANCE WITH ASTM D 3951.
NSN:007797550
VALVE, SOLENOID.
ALUMINUM BODY. NORMALLY CLOSED.
REFERENCE NUMBER:CS072
REFERENCE NUMBER:CA060
CRITICAL APPLICATION ITEM
WESTFIELD HYDRAULICS INC DBA 53730 P/N 550100-040
VALCOR ENGINEERING CORP DBA 96487 P/N V5000-40
HONEYWELL INTERNATIONAL INC. DBA 99193 P/N 692545-1
PREP FOR DELIVERY
LINE ITEM 00003 TYPE OF COVERAGE: DLA DIRECT, CONUS
PKGING DATA-QUP:001
SHALL BE PACKAGED STANDARD COMMERCIAL IN ACCORDANCE WITH ASTM D 3951.
NSN:007888391
VALVE, SOLENOID.
24 VOLTS DC. MATERIAL:
ALUMINUM ALLOY. 400 PSI, OPERATING
POSITION: NORMALLY OPEN. USED IN THE FUEL
CONTROL SYSTEM OF THE CTC85 SERIES GAS TURBINE
ENGINE. E/I C-141 AIRCRAFT.
REFERENCE NUMBER:CA060
REFERENCE NUMBER:ZD025
REFERENCE NUMBER:CS187
CRITICAL APPLICATION ITEM
TRANSDIGM, INC. DBA AEROCONTROLEX 81833 P/N 6250-1-1
WESTFIELD HYDRAULICS INC DBA 53730 P/N 570100-01
VALCOR ENGINEERING CORP DBA 96487 P/N V8500-4000
HONEYWELL INTERNATIONAL INC. DBA 99193 P/N 692546-1
PREP FOR DELIVERY
LINE ITEM 00004 TYPE OF COVERAGE: DLA DIRECT, CONUS
PKGING DATA-QUP:001
SHALL BE PACKAGED STANDARD COMMERCIAL IN ACCORDANCE WITH ASTM D 3951.
NSN:010126086
VALVE, SOLENOID.
REFERENCE NUMBER:CA060
CRITICAL APPLICATION ITEM
WESTFIELD HYDRAULICS INC DBA 53730 P/N 550210
VALCOR ENGINEERING CORP DBA 96487 P/N V5000-123
PREP FOR DELIVERY
LINE ITEM 00005 TYPE OF COVERAGE: DLA DIRECT, CONUS
PKGING DATA-QUP:001
SHALL BE PACKAGED STANDARD COMMERCIAL IN ACCORDANCE WITH ASTM D 3951.
NSN:011164869
VALVE, SOLENOID
REFERENCE NUMBER:ZM008
REFERENCE NUMBER:CS120
REFERENCE NUMBER:ZD059
NOTE: SUPPLIERS ARE REQUIRED TO IDENTIFY SUB-CONTRACTORS AT TIME OF
QUOTING IF KNOWN. USE OF ANY SUB-CONTRACTOR SUPPLIER WILL REQUIRE JCP
CERTIFICATION APPROVAL.
REFERENCE NUMBER:ZD025
REFERENCE NUMBER:CS187
REFERENCE NUMBER:ZQA03
REFERENCE NUMBER:QE002
REFERENCE NUMBER:CQC04
CRITICAL APPLICATION ITEM
HAMILTON SUNDSTRAND CORPORATION 55820 P/N 161798-2
VALCOR ENGINEERING CORP DBA 96487 P/N V7000-07
IAW BASIC DRAWING NR 55820 161798
REVISION NR M DTD 04/24/2007
PART PIECE NUMBER: PIECE 161798-2
IAW REFERENCE QAP 13873 QAP-222
REVISION NR A DTD 04/14/2004
PART PIECE NUMBER:
PREP FOR DELIVERY
LINE ITEM 00006 TYPE OF COVERAGE: DLA DIRECT, CONUS
PKGING DATA - MIL-STD-2073-1D, 15 DEC 1999
QUP:001 PRES MTHD:AE CLNG/DRY:1 PRESV MAT:00
WRAP MAT:00 CUSH/DUNN MAT:NA CUSH/DUNN THKNESS:A
UNIT CONT:D3 OPI:M
INTRMDTE CONT:E5 INTRMDTE CONT QTY:076
PACK CODE:U
MARKING SHALL BE IN ACCORDANCE WITH MIL-STD-129.
SPECIAL MARKING CODE:ZZ -ZZ Special Requirements
PALLETIZATION SHALL BE IN ACCORDANCE WITH MD00100452 REV B DATED JULY 01, 2008
VALVE OPENINGS SHALL BE CLOSED WITH NONCORROSIVE
PLASTIC PLUGS OR END CAPS TO ENSURE NO DEBRIS
WILL CONTAMINATE VALVE FLOW WHEN IN OPERATION.
REFERENCE NUMBER:CS284
NSN:011315719
VALVE ASSEMBLY, FUEL.
CRITICAL APPLICATION ITEM
WESTFIELD HYDRAULICS INC DBA 53730 P/N 550290
HAMILTON SUNDSTRAND CORPORATION 55820 P/N 160459-100
VALCOR ENGINEERING CORP DBA 96487 P/N V27200-630-3
PREP FOR DELIVERY
LINE ITEM 00007 TYPE OF COVERAGE: DLA DIRECT, CONUS
PKGING DATA-QUP:001
SHALL BE PACKAGED STANDARD COMMERCIAL IN ACCORDANCE WITH ASTM D 3951.
NSN:011898270
VALVE,PURGE.
REFERENCE NUMBER:ZD071
REFERENCE NUMBER:ZD003
REFERENCE NUMBER:CA060
REFERENCE NUMBER:CS187
CRITICAL APPLICATION ITEM
WESTFIELD HYDRAULICS INC DBA 53730 P/N 550240
VALCOR ENGINEERING CORP DBA 96487 P/N V5000-177
HAMILTON SUNDSTRAND CORPORATION 99167 P/N 163084-1
PREP FOR DELIVERY
LINE ITEM 00008 TYPE OF COVERAGE: DLA DIRECT, CONUS
PKGING DATA - MIL-STD-2073-1D, 15 DEC 1999
QUP:001 PRES MTHD:ZZ CLNG/DRY:X PRESV MAT:XX
WRAP MAT:XX CUSH/DUNN MAT:XX CUSH/DUNN THKNESS:X
UNIT CONT:XX OPI:A
INTRMDTE CONT:E5 INTRMDTE CONT QTY:AAA
PACK CODE:U
MARKING SHALL BE IN ACCORDANCE WITH MIL-STD-129.
SPECIAL MARKING CODE:00 -00 No special marking
PALLETIZATION SHALL BE IN ACCORDANCE WITH MD00100452 REV B DATED JULY 01, 2008
PACKAGING SHALL BE IAW MIL-V-3
REFERENCE NUMBER:CS277
************************************************************************************************************
GLOSSARY
************************************************************************************************************
PACKAGING TEXT
THE FOLLOWING PARAGRAPH APPLIES TO ALL PACKAGING CALLED OUT IN THIS DOCUMENT:
ITEM DESCRIPTION TEXT
REFERENCE NUMBER CS187
CLASS I OZONE DEPLETING CHEMICALS ARE NOT TO BE
USED NOR INCORPORATED IN ANY ITEMS TO BE
DELIVERED UNDER THIS CONTRACT.THIS PROHIBITION
SUPERSEDES ALL SPECIFICATION REQUIREMENTS BUT
DOES NOT ALLEVIATE ANY PRODUCT REQUIREMENTS.
SUBSTITUTE CHEMICALS MUST BE SUBMITTED FOR
APPROVAL UNLESS THEY ARE AUTHORIZED BY THE
SPECIFICATION REQUIREMENTS.
REFERENCE NUMBER CA061
ADEQUATE DATA FOR THE EVALUATION OF ALTERNATE
OFFERS IS NOT AVAILABLE AT THE PROCUREMENT
AGENCY.THE OFFEROR MUST PROVIDE A COMPLETE
DATA PACKAGE INCLUDING DATA FOR THE APPROVED
AND ALTERNATE PART FOR EVALUATION.
REFERENCE NUMBER CS072
CLASS 3 THREADS APPLY TO THIS NSN.
REFERENCE NUMBER CA060
NO DATA IS AVAILABLE. THE ALTERNATE OFFEROR IS
REQUIRED TO PROVIDE A COMPLETE DATA PACKAGE
INCLUDING DATA FOR THE APPROVED AND ALTERNATE
PART FOR EVALUATION.
REFERENCE NUMBER ZD025
MERCURY OR MERCURY CONTAINING COMPOUNDS SHALL
NOT BE INTENTIONALLY ADDED TO<(>,<)> OR COME IN DIRECT
CONTACT WITH<(>,<)> ANY HARDWARE OR SUPPLIES FURNISHED
UNDER THIS CONTRACT. EXCEPTION: FUNCTIONAL MERCURY
USED IN BATTERIES, FLUORESCENT LIGHTS, REQUIRED
INSTRUMENTS; SENSORS OR CONTROLS; WEAPON SYSTEMS;
AND CHEMICAL ANALYSIS REAGENTS SPECIFIED BY NAVSEA.
PORTABLE FLUORESCENT LAMPS AND PORTABLE INSTRUMENTS
CONTAINING MERCURY SHALL BE SHOCK PROOF AND CONTAIN
A SECOND BOUNDARY OF CONTAINMENT OF THE MERCURY OR
MERCURY COMPOUND. (IAW NAVSEA 5100-003D).
REFERENCE NUMBER ZM008
If this NSN provides Contract Data Requirement Lists (CDRLs) as part of
the Technical Data Package, the line items from this solicitation are
not to be separately priced. Offerors must factor into the end item
unit price all costs associated with the preparation and delivery of the
data deliverables in the contract.
REFERENCE NUMBER CS120
NOTE: THE CITED DRAWING IS A SOURCE CONTROLLED
DRAWING AND AS OF THE DATE OF THIS SOLICITATION
ONLY THE SOURCE(S) CITED ON THE DRAWING HAVE
BEEN APPROVED. EVEN THOUGH SOURCES AND APPROVED
PART NUMBERS ARE PROVIDED, THE ITEMS
FURNISHED MUST MEET THE REQUIREMENTS OF THE
CITED DRAWING. OFFERORS WHO ARE INTERESTED IN
QUALIFYING THEIR PRODUCT FOR PURPOSE OF FUTURE
ACQUISITION MUST CONTACT THE COGNIZANT DESIGN
ACTIVITY SPECIFIED ON THE SOURCE CONTROLLED
DRAWING.
ALSO, MAY INCLUDE ADDITIONAL APPROVED SOURCES
THAT HAVE NOT BEEN REFLECTED ON THE DRAWING AT
THIS TIME.
REFERENCE NUMBER ZD059
52.246-11 Higher Level Contract Quality Requirement (Manufacturers)
FAR CLAUSE 52.246-11 APPLIES. A QUALITY MANAGEMENT PROGRAM MEETING THE
REQUIREMENTS OF ISO 9001:2008; A PROGRAM COMPARABLE TO ISO 9001:2008
(EXAMPLE SAE AS 9100), THE FOLLOWING TAILORED VERSION OF ISO 9001:2008;
OR A PROGRAM COMPARABLE TO THE TAILORED VERSION OF ISO 9001:2008
(EXAMPLE SAE AS 9003) IS REQUIRED. MIL-I-45208 AND MIL-Q-9858 ARE
OBSOLETE AND NO LONGER CONSIDERED SUITABLE WHEN HIGHER LEVEL QUALITY IS
REQUIRED. IN THE TAILORED VERSION OF THE ISO 9001:2008, ANY REFERENCES
WHICH CITE THE ENTIRE INTERNATIONAL STANDARD ARE INTERPRETED AS
EXCLUSIONS TO THIS DOCUMENT.
DLA TAILORED HIGHER LEVEL QUALITY CLAUSE FROM ISO 9001:2008
4.1 General requirements, [excluding reference to 1.2 and excluding NOTE
3 c)]
4.2.1 General, [excluding subparagraph a)]
4.2.2 Quality manual, [excluding subparagraph a)]
4.2.3 Control of documents
4.2.4 Control of records
5.1 Management commitment
5.3 Quality policy
6.2.2 Competence, training and awareness
6.4 Work environment
7.1 Planning of product realization, [excluding NOTE 2]
7.2.1 Determination of requirements related to the product
7.2.2 Review of requirements related to the product
7.2.3 Customer communication
7.3.7 Control of design and development changes
7.4.1 Purchasing process
7.4.3 Verification of purchased product
7.5.1 Control of production and service provision
7.5.3 Identification and traceability
7.5.4 Customer property
7.5.5 Preservation of product
7.6 Control of monitoring and measuring equipment
8.1 General, [excluding subparagraph b) and subparagraph c)]
8.2.2 Internal audit
8.2.4 Monitoring and measurement of product
8.3 Control of nonconforming product
8.5.2 Corrective action
8.5.3 Preventive action
REFERENCE NUMBER ZQA03
THIS IS A NAVY IDENTIFIED CRITICAL SAFETY ITEM
(CSI).
ALL REQUESTS FOR WAIVERS OR DEVIATIONS MUST BE
FORWARDED TO THE DSC CONTRACTING OFFICER FOR
REVIEW AND APPROVAL.
.
ALL ITEMS OF SUPPLY SHALL BE MARKED IAW
MIL-STD-129. IN ADDITION, EACH UNIT PACK WILL
BE MARKED WITH LOT AND SERIAL NUMBER (IF AVAILABLE),
CONTRACTOR'S CAGE CODE, ACTUAL MANUFACTURER'S
CAGE CODE AND PART NUMBER.
REFERENCE NUMBER QE002
CLAUSE 52.246-15, CERTIFICATE OF CONFORMANCE, IS
NOT AUTHORIZED FOR THIS NSN.
REFERENCE NUMBER CQC04
DLAD 52.246-9003, MEASURING AND TEST EQUIPMENT,
APPLIES.
REFERENCE NUMBER CS284
EACH UNIT PACKAGE WILL BE MARKED WITH THE NSN,
CONTRACT NUMBER, LOT NUMBER, CONTRACTOR CAGE
CODE, MANUFACTURER CAGE CODE, AND PART NUMBER.
REFERENCE NUMBER ZD071
Configuration Change Management - Engineering Change Proposal, Requests
for Variance (Deviation or Waiver) February 2015
1. Requirements
A. The Configuration Change Management section of SAE EIA-649-1
Configuration Management Requirement for Defense Contracts, Paragraph
3.3, shall be used for Configuration Control of material purchased under
this contract.
B. Furnished item(s) shall conform to the approved configuration
requirements/revision specified, unless a Pre-Production Request for
Variance (deviation) or a Post-Production Request for Variance (waiver),
is processed and approved as provided by Paragraph 3. in this Standard
Text Object (STO). Hereafter, the term #Request for Variance (RFV)#
will also include Requests for Deviations and Waivers.
2. The definitions from EIA-649-1 apply to items being procured under
this solicitation/contract, with the following clarification of
Deviation & Waiver:
A. Pre-Production RFV (previously known as deviation) requests
permission to produce a product that does not conform to contract
requirements/documentation for a limited amount of time and for
specified effectivity. (A deviation differs from an engineering change
in that an approved engineering change requires corresponding revision
of the item's current approved configuration documentation, whereas a
deviation does not.).
B. Post-Production RFV (previously known as waiver) requests
approval of product found during manufacture, or after having been
submitted for Government inspection or acceptance, that departs from
specified requirements, but nevertheless is considered suitable for use
"as is" or after repair by an approved method.
3. Contractor responsibilities.
A. An Engineering Change Proposal (ECP) is used to make permanent
changes in the Government technical data package (TDP). Pending
approval of an ECP, contractual relief should be requested in writing by
the Contractor using a RFV.
B. Refer to FAR Part 48 Value Engineering for cost saving
improvements to the Technical Data Package (TDP).
C. All ECPs submitted by the Contractor will be deemed routine.
If the Contractor considers an ECP as an emergency or urgent; they
shall include in their ECP submittal an explanation and all applicable
supporting documentation. All ECPs will be reviewed for a determination
on criticality, and, if concurred to be an emergency, the appropriate
processing time-frame negotiated with the ESAs will be followed and the
Contractor will be notified of anticipated response time.
D. For ECPs, Specification Change Notices (SCNs) or RFV, the
Contractor must submit the applicable documentation listed in
sub-paragraphs D.(1) through D.(4)to the Administrative Contracting
Officer(ACO), with an information copy to the Procuring Contracting
Officer (PCO). Failure to submit a complete legible package may result
in return of the ECP/RFV without processing.
(1) Documentation listed in Paragraph 3.3.1 (for ECPs), 3.3.2
(RFV), 3.3.3 (for SCNs) or 3.3.4 (for Notices of Revision (NORs)) of the
latest revision of EIA-649-1.
(2) DD Form 1692 (current revision) for ECP.
(3) DD Form 1694 (current revision) for RFV.
(4) DD Form 1695 (current revision) for NOR.
4. DLA#s responsibilities:
A. Upon receipt of the ECP or RFV, the PCO will ensure that the
applicable product specialist receives the copy from DCMA.
B. Within five (5) working days from the date of receipt of the
Contractor's ECP or RFV from DCMA, the PS must submit the requests and
any supporting documentation via a 339 to the appropriate Engineering
Support Activity (ESA), when applicable.
C. Routine ECPs will be processed within 90 days from receipt by
the ESA. RFVs will be evaluated and processed within 30 days from
receipt by the ESA or as negotiated with the ESA.
(1) The contractor will be notified in writing of approval by
the return of an approved copy of the ECP or RFV. Approval will be
reflected by signature of the contracting activity or a review activity
specifically identified in the contract.
(2) The contractor will be notified in writing of disapproval
including reason(s) for disapproval.
5. For an approved RFV or an approved ECP, when the request affects the
Contract, a modification will be issued to the contract incorporating
the applicable requirement changes. Only a Contracting Officer is
authorized to issue a modification incorporating the approved RFV and/or
ECP.
6. Questions regarding the status of previously submitted ECP or RFV
should be directed to the PCO.
7. The submission of an ECP or RFV by the Contractor does not affect
the required delivery date of the contract. If a delivery date change
is needed, it must be negotiated with the Contracting Officer and
documented via modification to the contract.
8. The period of time for evaluation and approval/disapproval of an ECP
and/or a RFV, as specified in Paragraph 4. C., shall not constitute
excusable delay in the performance of this Contract by the Contractor or
in any way relieve the contractor from compliance with the contract
delivery schedule. The submission of an ECP and/or RFV by the
Contractor shall not preclude the Government from exercising its rights
under any clause of the Contract. (End)
REFERENCE NUMBER ZD003
A metal casting process was identified as a means to manufacture this
item. Tooling is required to produce a casting. For sourcing,
tooling, materials or other information, please contact the appropriate
assistance team: (Aviation, C&E Supply Chains) DSCR.AFCAT@dla.mil; (Land
& Maritime Supply Chains) DSCC.cast.forge@dla.mil
REFERENCE NUMBER CS277
"PRESERVATION AND PACKAGING SHALL BE
I-A-W THE LATEST REVISION OF FEDERAL
SPECIFICATION MIL-V-3, VALVES, FITTINGS
& FLANGES."
"WHEN ZZ IS THE METHOD OF PRESERVATION, USE
LEVEL "A" PRESERVATION AS CITED IN THE
COMMODITY SPECIFICATION."
Attachments
| File | Type | Posted |
|---|---|---|
| CM14125002_LTC_Market_Survey.docx | DOCX document | |
| CM14125002_Market_Survey_Spreadsheet.xlsx | XLSX spreadsheet |
Notice history
| Notice | Type | Posted |
|---|---|---|
| Valves | Award Notice | |
| Valve, solenoid | Award Notice | |
| Valves | Award Notice |
On GovTribe
Work this opportunity on GovTribe
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity