VA250-16-AP-3415 Zeiss Eye Equipment

Award Notice Posted

Solicitation number
VA25016Q0507
Agency
Awarded
to Proaim Americas, Llc.
Set-aside
No set-aside

Opportunity facts

Contract number
VA250-16-P-2653 Federal contract award
NAICS code
333314 Optical Instrument and Lens Manufacturing
PSC
Not on record

Notice details come from SAM.gov. Updated .

Notice text

This Sources Sought Notice is for informational and planning purposes only and shall not be construed as a solicitation or as an obligation or commitment by the Government at this time. This notice is intended strictly for market research. The purpose of this Sources Sought notice is to determine interest and capability of potential qualifications of a Service Disabled Veteran-Owned Small Business (SDVOSB) and a Veteran Owned Small Business (VOSB) firms relative to the North American Industry Classification Code (NAICS) 333314.The Department of Veteran's Affairs is seeking small business manufacturer or distributors of small business manufacturers, of functionally equivalent equipment to all the following: This equipment is required to provide full Eye Exams and is currently used in the Eye Center & CBOC eye lanes. The OCT is to perform Fluorescein angiography, Indocyanine green angiography, autofluorescence, color photography, and Optical Coherence Tomophraphy simultaneously of the patient's eye. Providing multi-modality imaging including 3-Dimensional and video images in one piece of equipment performing spectral domain Optical Coherence Tomopraphy, confocal laser scanning, and blue laser autofluorescense. This combination of three separate pieces of equipment streamlines the testing required and thereby reducing Veteran wait time in clinic as well as the number of return visits to complete all required testing.



The Visucam is to photograph through pupils as small as 3.3mm. Superior patient comfort, more efficient workflow and improved eye care.



The HFA3 is utilized for glaucoma diagnostics and management. This exact equipment has already been reviewed by Biomed when purchased for the Eye Center eye lanes.

All start up supplies must be compatible with the purchased system.

Specifications are outlined below (or equal):



QTY - 2 / 266002-1160-801-P... ZEISS OS | VISUCAM 524 W/PRINTER AND TABLE



QTY - 2 / 266002-1160-391-P... ZEISS OS | CIRRUS HD-OCT (MODEL 5000) WITH ANGIOPLEX OCT

ANGIOGRAPHY VERSION 9.0 (INCLUDES SMART HD SCANS,

FASTTRAC, ADVANCED RPE, GCA, ANTERIOR SEGMENT BASIC,

PRINTER & TABLE) (INCLUDES ANTERIOR SEGMENT PREMIER)





Has the capability to have the ability to capture and provide OCT Angiography:

This capability for OCT Angiography is provided by a 1 single OCT scan that

allows for visualization of both micro vascular and structural information in an

noninvasive dye free scan by the OCT.

Has the ability to import and integrate the Cirrus Model HD OCT 4000 raw data.

The raw data must be interchangeable between the Cirrus 4000 and Cirrus 5000

unit (or new unit being procured).

The unit must have exact Macular Scan Pattern of 512x128 for retina scan with

exact scanning speed at 27,000 A-scans a second within a 6mmx6mm. Must be

able to provide on Company Literature

The unit must have exact scan pattern of 200x200 in a 6mmx6mm cube for

Glaucoma Scan with exact scanning speed at 27,000 A-scans a second. The scan

pattern must be able to capture and provide RNFL, ONH, Neuro Retinal Rim

Tissue, and 3-D Cube capabilities all in one scan

Scanning speeds: Scan at exactly 27,000 A-scans/sec, as well as the ability to

scan at 68,000 A-scans/sec Unit must be able to provide a report for Ganglion Cell Analysis that is derived from a scan must be comprised of 6mmx6mm cube scan with a minimum by 200x200 line scan pattern with no more than 30 microns between each slice.

Minimum Pupil Requirements must be 2.0mm or less.

Unit must utilize an LSO Fundus Camera (Line Scanning Laser Ophthalmoscope).

The unit must Automatically Track to Prior Scan: The unit must be able to do

this without technician needing to align to prior scan:

Anterior Segment scan that is at minimal 15.5 mm in length x 5.8 mm in depth,

which is the full view of the Anterior Chamber. Must be able to provide on

Company Literature.

Global Pachymetry report that is comprised of minimum of 24 radial scans and

must be at a minimum 9mm in length.

The unit must be a 90 degree configuration, so that the tech (operator) must sit to

the side (90 degrees) of the patient.

The unit must be wireless mouse driven, not joystick. Must be able to provide on

Company Literature

The unit must be a Self- contained unit: Dimensions: 26 L, 18 W, 21 High. That

does not require extra space for separate PC or components.

The unit must have the ability to provide a 12 radial HD line scan pattern for the

Macula/ Retina Region.

The unit must have the ability to provide an automated Glaucoma Scan report

that is on the same 1 page report with the HFA Visual Field Analyzer, which is

called "Combined Report". Via FORUM.

The unit must have the ability to provide an image that is averaged over 100

times thru selective profiling. Must be able to provide on Company Literature

The unit must have the ability to scan and acquire the Ganglion Analysis utilizing

scan pattern of 200x200 or 512x128 in a 6mmx6mm Cube that does NOT

include the Inner Limiting Membrane or the Retinal Nerve Fiber Layer.

The unit must have the ability to produce a Report that is called GPA (Guided

Progression Analysis).

Offers Cornea Pachymetry map that must be able to provide the Minimum Value,

Average Value, and Maximum value in Microns of Cornea Thickness in each of

the area of central 0-2mm, 2-5mm, and 5-7mm range.

Offers Magnetic Lens attachment for Speed and Efficiency when changing from

posterior to anterior segment scanning. The removal or add of the lens is

immediate, the anterior segment lens is not screwed on.

Technical Features: 2048 Pixel OCT Camera, Windows 7 operating system, Live

LSO Fundus Image, Frame Rate greater than 20Hz.

QTY - 2 / 266002-1157-764-P... ZEISS OS | ANTERIOR SEGMENT PREMIER MODULE (IMAGING & MEASUREMENTS) INCLUDES EXTERNAL LENS KIT



QTY - 2 / 266002-1145-773-P... ZEISS OS | HFA3 MODEL 860 W/ LIQUID TRIAL LENS, RELEYE, KINETIC, GPA, HEAD TRK, GAZE TRK, PRINTER & TABLE



****TECHNICAL SPECIFICATIONS****

Dimension: 46 L x 52 W x 58 H (cm) which is exactly equivalent to: 18.11 L x

20.47 W x 22.83 H (inch)

Electrical Requirement: 100-120v- 50/60 Hz, 4.0A

Internal Storage: 500 GB

Operating System: Windows 7-64 bit

Fixation Control

o Video eye monitor

o Heijl-Krakau blind spot monitor

o Gaze Tracking

o Head Tracking

o Vertex Monitoring

Visual Field Indexâ„¢: Summary measurement of the patient's visual field status,

expressed as a percent of a normal age-adjusted visual field.

Liquid Trial Lensâ„¢: Using Liquid pressure, delivers each patient's refractive

correction. Available correction range is -8 to +8 diopters. Spherical correction

only. Liquid Trial Lens available in model 860 only.

Smart Touch interface: Touch screen interface allows for a more efficient

workflow

RelEye: The RelEye fixation monitoring system allows for systematic and pin

point fixation inspection. The HFA 3 captures and keeps the image of the eye

during the testing and just after, prior to the Result Review Screen. RelEye

cannot be viewed on the HFA 3 after terminating the test. Using the HFA 3,

RelEye is also available in FORUM Glaucoma Workplace (minimum version

2.0.3). Only FORUM can keep the RelEye data stored for future usage for

exporting exams.

Guided Progression Analysis (GPA): GPA allows the doctor to compare visual

field status and progression to data collected from glaucoma subjects. GPA

provides statistically significant change as well as rate of change, and predict

future vision quality.

Connectivity: For comprehensive connectivity the HFA 3 can be connected to

FORUM (minimum version 3.2) with FORUM Glaucoma Workplace (minimum

version 2.0.3). DICOM conformant as per the DICOM Conformant Statement,

available at

http://www.zeiss.com/meditec/en_us/products---solutions/ophthalmology-optome

try/dicom.html

HFA 3 also supports common file folder sharing used by most Electronic Medical

Record Systems (EMR).

SITATM (Swedish Interactive Threshold Algorithm): A patented algorithm for fast and accurate visual field threshold measurements; it is the most commonly used test strategy and incorporates patient responses in real time.

SITA database: The SITA normative database contains normative data for SITA

Standard and SITA Fast 30-2, 24-2 and 10-2 threshold visual field test results

from healthy subjects aged 17 to 89.

SITA-SWAPâ„¢ / Blue-Yellow Perimetry: Replaces the Full Threshold and

FastPac strategies for testing SWAP visual fields due to the much shorter test

times available when utilizing SITA SWAP

STATPACâ„¢: It is a software package using normative values and patient data to

perform statistically analysis to help interpret test data. STATPAC is the

software, normative data and statistical analysis in HFA.

Kinetic Testing: In kinetic testing, light stimulus of fixed characteristics is

moved into the visual field from a non-seeing area, until it is detected by the

patient. Typically, the stimulus is brought toward the center from several

directions and the operator marks the location at which the patient first detects

the stimulus (threshold point). The HFA 3 provides a kinetic graphical interface

with full 180º testing range.

Glaucoma Hemifield Test (GHT): Compares points in the superior and inferior

Hemifield to provide analysis of test results. On 24-2 and 30-2 tests, the GHT

evaluates five zones in the superior field and compares these zones to their

mirrored zones in the inferior field. The GHT evaluates the severity of disturbed

points in each zone pair, relative to its normal database.

Legacy data: patient legacy data can be transferred from the HFA II and HFA II-i

to the HFA 3.

FORUM Glaucoma Workplace (minimum version 2.0.3)



THIS IS NOT A SOLICITATION AND DOES NOT OBLIGATE THE GOVERNMENT TO ISSUE A SOLICITATION. Please be advised that the Government will not pay for any information submitted under this announcement. The applicable North American Classification System (NAICS) Code for this requirement is 333314 (Optical Instrument and Lens Manufacturing). Responses are to be submitted by e-mail to john.tschirhart@va.gov, No later than 08/31/2016 @4:00pm. Email should contain the following information: Name of firm, Socio-Economic category of the firm (SDVOSB or VOSB), complete address, phone, and fax number of contact.

Files

File Type Posted
-8698.docx DOCX document
VA250-16-Q-0507-000.docx DOCX document

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors