USCGC Patoka Generator Repair
Closed Solicitation Posted
- Solicitation number
- 70Z02925QNEWO0015
- Agency
-
Coast Guard
Department of Homeland Security
- Responses due
- Set-aside
- Total Small Business
Opportunity facts
- NAICS code
- 238210 Electrical Contractors and Other Wiring Installation Contractors
- Place of performance
- Greenville, Mississippi 38701, United States
- Points of contact
Notice details come from SAM.gov. Updated .
About this opportunity
The U.S. Coast Guard is seeking a contractor to repair and service critical power systems aboard the USCGC Patoka, specifically requiring troubleshooting and repair of a 600-amp switchgear and a 100 kW diesel generator to return it to fully mission capable status. The contractor must provide all labor, materials, and equipment necessary for the work, including performing load testing to ensure proper operation. Key requirements include using electricians and diesel mechanics certified in Mississippi, compliance with the National Electric Code, and adherence to Coast Guard safety and security protocols. The contract will be awarded using a lowest price technically acceptable evaluation methodology under solicitation number 70Z02925QNEWO0015. Quotes must be submitted by September 24, 2025, with contractors required to be actively registered in the System for Award Management.
This procurement is designated as a total small business set-aside under NAICS code 238210 (Electrical Contractors and Other Wiring Installation Contractors). No incumbent contractors are identified in the solicitation documents. While no specific contract value is disclosed, the work must be completed within 120 calendar days, with a performance start period of 15 calendar days and completion timeframe of 60 calendar days after notice to proceed. The work will be performed at the USCGC Patoka facility located at 1797 Harbor Front Road in Greenville, Mississippi 38701, with normal working hours from 7:00am to 4:00pm, Monday through Friday. The solicitation indicates this is a firm-fixed price construction contract with no performance or payment bonds required.
Notice text
This is a combined synopsis/solicitation for non-commercial items prepared in accordance with the format in FAR Part 36, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested, and no other written solicitation will be issued.
Instructions to offerors, (FAR Part 36) evaluation criteria, and all applicable FAR Provisions and Clauses are attached.
The solicitation number is 70Z02925QNEWO0015 and is issued as a Request for Quotation (RFQ).
The solicitation document and incorporated provisions and clauses.
Federal Acquisition Regulation (FAR) Clauses and Department of Labor Wage Rates for Construction are included in this order and are applicable.
Where Federal Acquisition Regulation clause language is inconsistent with FAR Part 36,
Legal Effect of Quotations, that language is hereby tailored in accordance with FAR Part 36 to be consistent with a request for quotations.
This tailoring includes but is not limited to the following: In accordance with FAR Part 36, a quotation is not an offer, and any clause provision to the contrary is hereby modified to be consistent with FAR Part 36. Where the word "offer/offeror" or a derivative of that word appears, it is changed to "quote/quoter" or a derivative of that word.
This is a small business set aside, the applicable NAICS code is 238210 and PSC code is Z2PZ
This solicitation will result in a Firm-Fixed Price Construction Contract awarded to the offeror with the Lowest Price. Offerors must actively be registered in System for Award Management - https://www.sam.gov
The USCGC Patoka has a requirement for the vendor to provide all labor, materials, and equipment necessary to remove and replace the following:
- Contractor shall troubleshoot and repair the 600-amp switchgear.
- Contractor shall troubleshoot, repair, and service 100 kW diesel generator returning it to fully mission capable.
- Contractor shall perform a load test to ensure generator is fully mission capable.
- This summary is not all inclusive and delineates only the work items deemed as major to the contract. Ancillary work items necessary to attain the completed project shall be included in the contract as inherent to the work.
Please see the attached Statement of Work for specifications of work, illustrations and POC’s for setting up site visits.
30 DAY ARO
FOB Destination to:
USCGC Patoka
1797 Harbor Freight Road
Greenville, MS 38701
FAR 52.237-1 - Site Visit. Offerors or quoters are urged and expected to inspect the site where services are to be performed and to satisfy themselves regarding all general and local conditions that may affect the cost of contract performance, to the extent that the information is reasonably obtainable. In no event shall failure to inspect the site constitute grounds for a claim after contract award.
The Government Point of Contacts (POC) for this project is:
MKC Jacob Newland
Jaocb.m.newland@uscg.mil
662 394 9746
All work shall be coordinated through the POC.
All quotes are due at by 5:00pm CST on September 24, 2025. Submit quotes to the following e-mail address: Wesley.k.hanna@uscg.mil, all questions regarding this solicitation shall be submitted to the Purchasing Agent at Wesley.k.hanna@uscg.mil no later than September 23, 2025, 5:00pm CST or the question may not be answered.
Files
| File | Type | Posted |
|---|---|---|
| IMG_7944.jpeg | JPEG file | |
| IMG_7942.jpeg | JPEG file | |
| SF 1442.pdf | ||
| IMG_7943.jpeg | JPEG file | |
| IMG_7871.jpeg | JPEG file | |
| Wage Rates MS20250046.txt | TXT text file | |
| IMG_7941.jpeg | JPEG file | |
| SOW.docx | DOCX document | |
| Construction Clauses (Mar) 2025.odt | ODT document | |
| IMG_7870.jpeg | JPEG file | |
| 77367764381__A30DCEAF-FC1E-4893-8CE9-4742647D5CFD.jpeg | JPEG file |
Show all 11
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Inspect and Repair of 13.2KV Main Switchgear | — | Total Small Business | |
| MH-65 Power Supply Assembly Repair | Coast Guard | Total Small Business | |
| Drydock repairs for the CGC pamlico | — | Total Small Business | |
| Open, Inspect, Report and Overhaul of Circuit Breakers | Coast Guard | Total Small Business | |
| Drydock Repairs USCGC HATCHET (WLIC-75309) | — | Total Small Business |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity