USCGC chena car port project

Closed Solicitation Posted

Solicitation number
70Z02926QGALV0064
Agency
Responses due
Set-aside
Total Small Business

Opportunity facts

Place of performance
Hickman, Kentucky 42050, United States

Notice details come from SAM.gov. Updated .

About this opportunity

The U.S. Coast Guard seeks installation of a new 25-by-30-foot pre-fabricated galvanized metal carport with a 14-by-14-foot roll-up garage door at USCGC Chena in Hickman, Kentucky, with proposals due August 21. This procurement is a total small business set-aside, foreclosing competition outside that category.

Place of performance is USCGC Chena, 503 Hall Street, Hickman, Kentucky 42050. The NAICS code is 236220, Commercial and Institutional Building Construction, with a 45-employee small business size standard. The PSC is Y1AZ.

The contractor must be Kentucky-certified for the installation work. The contractor shall acquire all necessary permits, provide all labor, tools, equipment, and materials, and ensure compliance with all applicable state and federal codes. The contractor must perform at least 50 percent of total contract work on-site using its own forces, including laborers, mechanics, and foreman or superintendent on the contractor's payroll under direct supervision. Material and equipment costs installed by such labor may be included in this calculation. The contractor must submit a statement with its cost schedule designating which portions will be performed by the contractor's own forces.

The current carport will be demolished by Coast Guard personnel; the contractor is responsible for pavement anchors, utility location and marking, protecting existing structures and vegetation, and waste removal and disposal. Work is performed Monday through Friday, 7:00 AM to 4:00 PM, within a 14-calendar-day performance period. The contractor must commence work within 10 calendar days of notice to proceed and complete work within 30 calendar days thereafter.

This is a firm-fixed-price construction contract awarded to the lowest-price technically acceptable offeror. Performance and payment bonds are not required. All contractors must be actively registered in SAM.gov. The contractor must submit a personnel roster, construction schedule, safety plan, and product data sheets for pre-construction approval, and provide Operation and Maintenance Manuals and training upon completion.

Notice text

CGC Chena Car port construction Project

NAICS: 236220 (Commercial and Institutional Building Construction)

PSC: Y1AZ

United States Coast Guard Cutter Obion is accepting proposals for qualified individuals or firms, to install a new car port at USCGC Cutter Chena in Hickman, KY. All work being performed must be up to state and federal code. Should any permits need to be required to perform this project, the contractor shall acquire all necessary permits for the project and provide all labor, tools, equipment and materials to complete the project.

location of service:

USCGC Chena

503 Hall St  

Hickman, KY 42050

This is a combined synopsis/solicitation. All work is to be completed in accordance with the scope of work. This announcement constitutes only the solicitation; quotes are being requested, and no other written solicitation will not be issued. This is a Small Business Set-aside, the applicable NAICS code is 236220 and small business size standard is 45M. This solicitation will result in a Firm-Fixed Price Construction Contract awarded to the offeror with the Lowest Price Technically Acceptable.

Offerors must be actively registered in System for Award Management - https://www.sam.gov.

All work is to be completed in accordance with the SOW. This will be a firm-fixed priced purchase order awarded to the lowest reasonable price technically acceptable bidder. This is set aside 100% for small business. All contractors must be actively registered in SAM.gov and must provide representations prescribed in clause 52.236-1 in Section III and see attachment B to be considered. 

The Contractor shall submit, simultaneously with the schedule of costs required by the Payments under Fixed-Price Construction Contracts clause of the contract, a statement designating the portions of contract work to be performed with the Contractor's own forces. The approved schedule of costs will be used in determining the value of a work activity/event, or portions thereof, of the work for the purpose of this article. In establishing the percent of work to be performed by the Contractor. Cost of material and equipment installed by such labor may be included. The work by the Contractor's executive, administrative and clerical forces shall be excluded in establishing compliance with the requirements of this clause.

FAR 52.237-1 -- Site Visit (Apr 1984). Offerors or quoters are urged and expected to inspect

the site where services are to be performed and to satisfy themselves regarding all general and local conditions that may affect the cost of contract performance, to the extent that

the information is reasonably obtainable. In no event shall failure to inspect the site constitute grounds for a claim after contract award.

Arrangements for mandatory site visits may be made by contacting:

MKC Brandon Upchurch

Brandon.M.Upchurch@uscg.mil

(571) 610-5260

 Submit quotes to: Jonathan.d.thomas@uscg.mil  and James.J.Spenn@uscg.mil

NAICS: 236220

 PSC: Y1AZ

36.204 Disclosure of the magnitude of construction projects.

Advance notices and solicitations shall state the magnitude of the requirement in terms of physical characteristics and estimated price range. In no event shall the statement of magnitude disclose the Government’s estimate. Therefore, the estimated price should be described in terms of one of the following price ranges:

(a) Less than $25,000.

Files

File Type Posted
70Z02926QGALV0064_0_US.pdf PDF
Attachment B (INSTRUCTIONS).pdf PDF
SOW CHENA Carport.pdf PDF

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity