USCG South Portland Door Replacement
Closed Solicitation Posted
- Solicitation number
- 37000PR26000072Doors
- Agency
-
Coast Guard
Department of Homeland Security
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 238290 Other Building Equipment Contractors
- Place of performance
- South Portland, Maine 04106, United States
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of Homeland Security US Coast Guard seeks replacement of interior and exterior doors at its South Portland, Maine antiterrorism facility, with proposals due September 1. No set-aside applies.
Place of performance is 259 High Street, South Portland, Maine 04106. The scope includes removal and installation of ten single interior doors and one double interior door, along with eight single exterior doors and two double exterior doors, all as "like-and-kind" units. Exterior openings must achieve complete watertight seals; door frames must be replaced where necessary. All new doors must meet applicable fire ratings. Commercial-grade hardware includes a BEST key lock system with 7-pin core and pin code manual locks with mechanical keypads on designated doors. Period of performance is 30 days from Notice to Proceed, with work conducted Monday through Friday, 0700 to 1530 hours, excluding Federal Holidays. All work dates require confirmation 24–48 hours in advance with the Contracting Officer's Representative. The contractor may reschedule up to two business days for inclement weather.
Contractor personnel must be U.S. citizens or legally authorized to work in the United States with valid government-issued photo identification. All wage rates and benefits must comply with the Service Contract Act and Davis-Bacon Act. Contractors must provide proof of insurance, submit manufacturer product data and shop drawings for COR approval prior to ordering materials, and warrant all work and materials for one year from final acceptance. A pre-bid site visit is highly encouraged. Daily debris removal and localized testing for hazardous materials (lead and asbestos) are contractor responsibilities. The NAICS code is 238290, Other Building Equipment Contractors; PSC is Z2AA, Repair or Alteration of Office Buildings.
Notice text
The Contractor shall safely remove specified doors, including frames, sills, and associated hardware, and install new "like-and-kind" units to enhance the facility's weather resistance, security, and energy efficiency in accordance with the attached Statement Of Work (SOW).
quoters must provide proof of insurance
All wage rates and benefits must be in accorance with the SCA / Davis Bacon Act for the disiplan of work, Place of Preformance and Period of Preformance.
Files
| File | Type | Posted |
|---|---|---|
| Construction CLAUSES 2026.docx | DOCX document | |
| DEI_FAR_Clause.docx | DOCX document | |
| STATEMENT OF WORK Door Replace.docx | DOCX document |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| EC-ECAO Exterior Door Replacement | — | Total Small Business |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity