Upgrade of Campground Electrical Pedestals to 50 Amp - Winnie Dam, MN

Award Notice Posted

Solicitation number
W912ES-16-T-0058
Agency
Awarded
to Bessler Brothers Electric, LLC
Set-aside
Total Small Business

Opportunity facts

Contract number
W912ES-16-P-0056 Federal contract award
NAICS code
238210 Electrical Contractors and Other Wiring Installation Contractors
PSC
Not on record
Place of performance
Winnie Dam Campground 56787 County Road # 9 Deer River, Minnesota 56636, United States

Notice details come from SAM.gov. Updated .

Notice text

3 versions

Update #3 · Latest ·

The contractor shall supply all materials, equipment and labor necessary to replace current campsite electrical pedestals with new 50 amp campsite pedestals at the Winnibigoshish Dam Recreation Area (Winnie Dam campground). There are 22 power pedestals, located at campsites 1-22, on two loops of 11 campsites/pedestals to be upgraded.

Each pedestal shall have a 50 amp receptacle, a 30 amp receptacle and 20 amp GFCI receptacle, and a 50 amp, 30 amp and 20 amp circuit breaker installed. Balance panelboard circuits for all electrical campground sites. Replace existing feed and service conductors to pedestals, complying with cultural protection recommendations by placing new conductors within the same trench/area as the removed conductors.

Contractor is responsible for obtaining and complying with all permits necessary and complying with all local, County and State codes.

This solicitation is a Request for Quote (RFQ) with a 100% Small Business Set-Aside.
NAICS Code: 238210
Size Standard: $15 million

Quotes must be accompanied by a copy of the Electrical Contractor License, and a statement of relevant experience (similar design/installation work).

It is preferred that quotes are emailed.

Amendment 0001 is issued to remove the requirement for a MN Electrical License.  The Contractor may be a licensed electrical contractor from any US state.  All work must be performed to the current MN Electrical Code.

Amendment 0002 is issued to extend the completion date to 21 October 2016.

Update #2 ·

The contractor shall supply all materials, equipment and labor necessary to replace current campsite electrical pedestals with new 50 amp campsite pedestals at the Winnibigoshish Dam Recreation Area (Winnie Dam campground). There are 22 power pedestals, located at campsites 1-22, on two loops of 11 campsites/pedestals to be upgraded.

Each pedestal shall have a 50 amp receptacle, a 30 amp receptacle and 20 amp GFCI receptacle, and a 50 amp, 30 amp and 20 amp circuit breaker installed. Balance panelboard circuits for all electrical campground sites. Replace existing feed and service conductors to pedestals, complying with cultural protection recommendations by placing new conductors within the same trench/area as the removed conductors.

Contractor is responsible for obtaining and complying with all permits necessary and complying with all local, County and State codes.

This solicitation is a Request for Quote (RFQ) with a 100% Small Business Set-Aside.
NAICS Code: 238210
Size Standard: $15 million

Quotes must be accompanied by a copy of the Electrical Contractor License, and a statement of relevant experience (similar design/installation work).

It is preferred that quotes are emailed.

Amendment 0001 is issued to remove the requirement for a MN Electrical License.  The Contractor may be a licensed electrical contractor from any US state.  All work must be performed to the current MN Electrical Code.

Update #1 ·

The contractor shall supply all materials, equipment and labor necessary to replace current campsite electrical pedestals with new 50 amp campsite pedestals at the Winnibigoshish Dam Recreation Area (Winnie Dam campground). There are 22 power pedestals, located at campsites 1-22, on two loops of 11 campsites/pedestals to be upgraded.

Each pedestal shall have a 50 amp receptacle, a 30 amp receptacle and 20 amp GFCI receptacle, and a 50 amp, 30 amp and 20 amp circuit breaker installed. Balance panelboard circuits for all electrical campground sites. Replace existing feed and service conductors to pedestals, complying with cultural protection recommendations by placing new conductors within the same trench/area as the removed conductors.

Contractor is responsible for obtaining and complying with all permits necessary and complying with all local, County and State codes.

This solicitation is a Request for Quote (RFQ) with a 100% Small Business Set-Aside.
NAICS Code: 238210
Size Standard: $15 million

Quotes must be accompanied by a copy of the Minnesota Electrical Contractor (business) License, and a statement of relevant experience (similar design/installation work).

It is preferred that quotes are emailed.