Thomaston Lake Dam, Gate House Roof Repairs, Thomaston, CT
Open Pre-Solicitation Posted
- Solicitation number
- W912WJ-27-X-1CY2
- Agency
-
ENDIST New England
US Army Corps of Engineers, Department of Defense
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 238160 Roofing Contractors
- PSC
- Not on record
- Place of performance
- Thomaston, Connecticut 06787, United States
- Points of contact
Notice details come from SAM.gov. Updated .
About this opportunity
The U.S. Army Corps of Engineers, New England District is issuing Sources Sought Notice W912WJ-27-X-1CY2 to gauge interest in construction services for Gate House roof repairs at Thomaston Lake Dam in Thomaston, Connecticut, with responses due December 11, 2026. The Set Aside line reads "No Set-Aside Used," although the notice text states it seeks information from 8(a), HUBZone, Service-Disabled Veteran-Owned, Women-Owned, and small business concerns. The notice is for market research only and is not a Request for Proposal or a commitment to solicit. The project is planned for issuance in Spring 2027, with construction in Summer 2027, under NAICS 238160 with a $19 million size standard. The estimated construction cost is between $350,000 and $500,000. The Place of Performance field lists the District office at 696 Virginia Road, Concord, Massachusetts, while the work is performed at Thomaston Lake Dam in Thomaston, Connecticut. Scope includes removing and replacing the EPDM roof, thermal insulation, and associated components, enlarging the existing scupper, installing a new roof hatch and fall protection railing system, and replacing the lightning protection system. The attached file summary states that work over water at heights exceeding 45 feet requires special fall protection and that contractors must comply with USACE safety submittals. Interested firms must submit a capabilities package of up to 20 pages covering business classification, qualifications, at least two examples of relevant work from the last seven years, subcontractor information and experience, and proof of bonding capability. Responses go by email to Contract Specialist Brian Mannion at Brian.T.Mannion@usace.army.mil or (978) 318-8478. No incumbent is named.
Notice text
Action Code: Sources Sought Notice
Subject: Thomaston Lake Dam, Gate House Roof Repairs, Thomaston, CT
Sources Sought Number: W912WJ-27-X-1CY2
NACIS Code: 238160
Response date: December 11, 2026
Place of Performance:
US Army Corps of Engineers, New England District
696 Virginia Road
Concord, MA
01742-2751 US
The U.S. Army Corps of Engineers, New England District is issuing this Sources Sought Announcement for Construction Services for the repairs to the Gate House Roof at Thomaston Lake Dam in Thomaston, Connecticut. This announcement is to determine interest, availability and capability of 8(a), HUBZone, Service-Disabled Veteran-Owned,Women-Owned and Small Business concerns for this project. The NAICS code for this procurement is 238160 with a size standard of $19M. The project is planned to be issued in the Spring of 2027 with construction to take place in the Summer of 2027. The estimated construction cost is between $350,000 - $500,000.
Thomaston Lake Dam is situated on the Naugatuck River and is a part of a network of flood control dams and local protection projects built by the U.S. Army Corps of Engineers in the Upper Connecticut River Basin. The construction was completed in 1960.
The dam is located between Hill Road (to the east) and James H Darcey Memorial Highway (to the west). The dam consists of a rockfill earth gravity dam with stone slope protection 2,000-feet long and 137-feet high and a 435-foot-wide uncontrolled spillway.
The work of this project involves removing the existing EPDM roof, thermal insulation and all associated components and replace with new thermal insulation and roof membrane system. The existing roof has a parapet wall around the perimeter which an existing scupper exists. The existing scupper will be required to be enlarged. The work also includes installing a new roof hatch and fall protection railing system. The existing lightning protection system will be removed and replaced with a new lightning protection system.
The roof is approximately 35 feet above the service bridge deck which only accesses one side of the gate house tower. Work pertaining to the scupper will require special fall protection requirements as this side of the gate house tower is over water at a height greater than 45 feet. The contractor will need to comply and submit all required USACE safety submittals for this project.
Interested firms should submit a capabilities package to include the following: business classification (i.e. HUBZone, small business, etc.), as well as qualifications and experience in performing the work components stated above. Please include at least two specific examples of the firm’s experience performing the work requirements stated above. The projects must have been performed within the last seven years. Please indicate the team subcontractor(s) (if any), including their prior experience and qualifications, which will be used to support the offeror’s effort and their experience must also have been performed within the last seven years. Proof of bonding capability is required. Responses are limited to twenty pages. Responses are due by December 11, 2026. Responses should be emailed to:
CONTRACT SPECIALIST
Brian Mannion
Email: Brian.T.Mannion@usace.army.mil
Phone Contact: (978) 318-8478
The Government will not pay for any material provided in response to this market survey nor return the data provided. This notice is for information purposes only and is not a request to be placed on a solicitation mailing list nor is it a Request for Proposal (RFP) or an announcement of a solicitation. The results of this survey will be considered to be in effect for a period of one year from the date of this notice.
Government Agency URL: www.nae.usace.army.mil
Government Agency URL Description: New England District, Corps of Engineers
Files
| File | Type | Posted |
|---|---|---|
| Sources Sought.pdf |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Float Well Pipe Repairs, Surry Mountain Dam, Surry, NH | ENDIST New England | No set-aside | |
| Construction Services for replacing the wire ropes and designated associated sheave blocks, Franklin, New Hampshire. | ENDIST New England | No set-aside | |
| Building 434 Roof Repair | Naval Facilities Engineering Command | Competitive 8(a) | |
| Snow Removal and Sanding Services, Franklin Falls Dam, Franklin, NH | ENDIST New England | Total Small Business | |
| Dike B Generator Installation, Mansfield Hollow Dam, Mansfield Center, CT | ENDIST New England | Total Small Business |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity