The Department of the Army Materiel Command Contracting Command Rock Island Arsenal is seeking a contractor to provide certified inspectors for helium leak testing of one-metric ton containers at Tooele Army Depot (TEAD) in Tooele, Utah. The contractor must provide all necessary personnel, equipment, and services to perform the helium leak testing, except for the helium gas which will be supplied by TEAD. The inspector must be certified to NDT Level II or III, and the contractor must develop quality control procedures. A minimum of 400 containers will be tested in batches of 200. The contractor must also report to the Contract Manpower Reporting Application.
This solicitation is set aside for Total Small Business. The specific numerical details indicate a minimum of 400 containers will be tested. The place of performance is Tooele, UT 84074, USA.
Notice text
3 versions
Update #3 · Latest ·
Combined Synopsis/Solicitation.
This is a non-personnel services contract to provide a certified inspector from The American Society for Nondestructive Testing (NDT) Level 2 or 3, for One-Metric Ton Containers. The contractor shall provide all personnel, equipment, supplies, facilities, transportation, tools, materials, supervision, and other items and non-personal services necessary to perform Helium Leak Testing for One-Metric Ton Containers as defined in this Performance Work Statement (PWS), save helium gas, which will be supplied by TEAD. The contractor shall perform to the standards in this contract.
Vendor must meet requirements in the PWS.
The inspector shall be certified by The American Society for Nondestructive Testing (NDT) Level II or Level III.
The inspector shall submit NDT examiner certification records as well as eye exams in accordance with the (AWS) D1.1.
The contractor shall be capable of helium leak testing the one-metric ton containers at TEAD; Tooele, UT 84074
Please review the attached Performance Work Statement.
Update #2 ·
Combined Synopsis/Solicitation.
This is a non-personnel services contract to provide a certified inspector from The American Society for Nondestructive Testing (NDT) Level 2 or 3, for One-Metric Ton Containers. The contractor shall provide all personnel, equipment, supplies, facilities, transportation, tools, materials, supervision, and other items and non-personal services necessary to perform Helium Leak Testing for One-Metric Ton Containers as defined in this Performance Work Statement (PWS), save helium gas, which will be supplied by TEAD. The contractor shall perform to the standards in this contract.
Please review the atatched Performance Work Statement.
Update #1 ·
Combined Synopsis/Solicitation. Full details to follow.
Attachments
| File | Type | Posted |
|---|---|---|
| Performance Work Statement - Helium Leak Testing.pdf |
On GovTribe
Work this opportunity on GovTribe
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity