TEAD - Helium Inspection Services
Closed Solicitation Posted
- Solicitation number
- PANROC26P0000036026
- Agency
-
ACC Rock Island
Army Contracting Command, Department of Defense
- Responses due
- Set-aside
- Total Small Business
Opportunity facts
- NAICS code
- 541380 Testing Laboratories and Services
- Place of performance
- Utah 84074, United States
Notice details come from SAM.gov. Updated .
About this opportunity
ACC Rock Island (Department of the Army Materiel Command, Contracting Command Rock Island Arsenal) is soliciting quotes for helium leak inspection of 100 newly fabricated one-metric-ton mercury containers at Tooele Army Depot, with quotes due November 10, 2026 at 10:00 a.m. Central Time. The Set Aside line is Total Small Business. The October 26 Q&A states the solicitation is not posted on CHESS, superseding the earlier clause-attachment reference to a DoD CHESS ITES-3H BPA order. Amendment 0001 reduced the container quantity from 400 to 100 and the retest quantity from 25 to 10. Questions closed October 19, 2026.
Work is performed at Building 519, Tooele Army Depot, Utah, Monday through Thursday, 0630 to 1700 hours, during a period of performance from January 1, 2027 through December 31, 2027. The Government anticipates manufacturing containers at 10 to 20 per week, with all 100 expected by July 31, 2027, for one continuous testing mobilization. Testing personnel must hold ASNT Level II or Level III Leak Testing certifications under SNT-TC-1A, and employer-issued certifications are acceptable. Personnel require only a favorable local background check and installation security training; no security clearances or DD Form 254 apply.
The contractor pressurizes each container to 15.0 PSIG ±0.2 psi with an air-helium mixture of at least 50 percent helium, records pressure at initial, five-minute, and thirty-five-minute intervals, and scans welds and seals with a calibrated leak detector sensitive to 5E-6 std cm3/sec. Passing containers show a corrected leak rate below 1.0E-5 std cm3/sec and no pressure decrease exceeding 0.1 psi. The contractor furnishes all testing equipment, helium, test plugs, gauges, and hoses and must submit a Leak Test Inspection Procedure before work begins, a final report listing all containers with pass/fail status, and a leak detector calibration certificate. The Government furnishes the containers, a forklift with operator, facilities, utilities, and training.
Award goes to the responsible quoter with the lowest total evaluated price conforming to specifications, made as a single award without meaningful exchanges. Technical and past performance are not evaluated. Pricing must use the Excel Pricing Matrix (Attachment 0001) with working formulas, and quotes must be emailed to Contract Specialist Rebecca Meeke and Contracting Officer Megan Frost with the company name and CAGE code current. Quotes remain valid for 60 days after the closing date.
Notice text
4 versions
Update #4 · Latest ·
Final QUESTIN/ANSWERS Spreadsheet uploaded.
_____________________________________________________________________________
QUESTIONS/ANSWERS POSTED. Solicitation extended to 10 Nov 2026, 10am(CT).
______________________________________________________________________________
Amendment 0001 - 1st paragraph page 1, changed quantity of 400 to 100 and 25 to 10.
_______________________________________________________________________________
Requirement - Helium Inspection Services.
Read all attachments.
Please make certain Cage Code is current.
Update #3 ·
QUESTIONS/ANSWERS POSTED. Solicitation extended to 10 Nov 2026, 10am(CT).
______________________________________________________________________________
Amendment 0001 - 1st paragraph page 1, changed quantity of 400 to 100 and 25 to 10.
_______________________________________________________________________________
Requirement - Helium Inspection Services.
Read all attachments.
Please make certain Cage Code is current.
Update #2 ·
Amendment 0001 - 1st paragraph page 1, changed quantity of 400 to 100 and 25 to 10.
_______________________________________________________________________________
Requirement - Helium Inspection Services.
Read all attachments.
Please make certain Cage Code is current.
Update #1 ·
Requirement - Helium Inspection Services.
Read all attachments.
Please make certain Cage Code is current.
Files
| File | Type | Posted |
|---|---|---|
| QUESTIONS - ANSWERS.xlsx | XLSX spreadsheet | |
| QUESTIONS - ANSWERS.xlsx | XLSX spreadsheet | |
| B08 - Solicitation - Helium Inspection Services -- Amendment 0001 final.pdf | ||
| B08 - Solicitation - Helium Inspection Services -- final.pdf | ||
| B08 - TEAD - Clauses_Final - Attachment 0002.pdf | ||
| B08 - Attachment 0003 - PWS - Helium Leak Inspection Service_final_8.25.2026.pdf | ||
| B08 - Attachment 0001 - Pricing Matrix.xlsx | XLSX spreadsheet |
Notice history
| Notice | Type | Posted |
|---|---|---|
| This notice | Solicitation | |
| TEAD - Helium Inspection Services | Pre-Solicitation |
On GovTribe