Synopsis - Repair WHCA POL Tanks
Closed Pre-Solicitation Posted
Not the latest version. See the latest solicitation from .
- Solicitation number
- FA706024R0003
- Agency
-
District Washington
Headquarters Air Force, Department of Defense
- Responses due
- Set-aside
- Total Small Business
Opportunity facts
- NAICS code
- 237120 Oil and Gas Pipeline and Related Structures Construction
- Place of performance
- Bolling AFB, District of Columbia 20032, United States
Notice details come from SAM.gov. Updated .
About this opportunity
This pre-solicitation notice seeks design and construction services for repairs to petroleum, oil, and lubricant storage tanks at White House Communications Agency facilities. The Department of the Air Force Headquarters District Washington requires removal and replacement of underground oil-water separators and oil storage tanks at two buildings, installation of new oil-water separators with integral oil storage and alarms, removal of an underground diesel tank to be replaced with above-ground diesel tanks featuring spill protection. The subsequent solicitation will result in a firm-fixed price contract award made to the lowest price technically acceptable offer in accordance with the requirements and Statement of Work to be provided.
The anticipated solicitation is designated for total small business set-aside with a North American Industry Classification System code of 237120 and business size standard of $45,000,000 in average annual receipts. Prospective contractors must register in SAM.gov as the solicitation package will be available there as well as on beta.SAM.gov no fewer than 15 days after this pre-solicitation notice. There is no current incumbent mentioned, however the project involves removal and replacement of approximately 10,000-gallon oil and diesel storage tanks at two WHCA facilities.
Notice text
The project is for the Design and Construction of petroleum, oil, and lubricant (POL) tanks for White House Communications Agency (WHCA). It includes removal of underground Oil-Water Separators in buildings 399 and 408 for WHCA , removal of oil storage tanks, and installation of new Oil-Water Separators with integral oil storage and alarms to alert when oil should be removed. It also includes the removal of an underground 10,000-gallon diesel tank, hole filled with engineered fill, and platforms built with spill protection for above-ground 10,000 gallon diesel oil tanks. Lastly, it provides all connections to the tanks and two 250-gallon ready service interior oil tanks with spill prevention measures to include double-walled piping. NOTE: Complete project details shall be provided via the Statement of Work at the time a solicitation is posted.
Files
| File | Type | Posted |
|---|---|---|
| SYNOPSIS - Repair WHCA POL Tanks.pdf |
Notice history
| Notice | Type | Posted |
|---|---|---|
| Repair WHCA POL Tanks | Solicitation | |
| This notice | Pre-Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Cleaning, Inspection, and Hazardous Waste Removal for Two 10, 000-Gallon Oil/Water Separators | Secretary of the Air Force | Total Small Business | |
| WH Ford RTC Fueling System Repairs | ENDIST Omaha | Total Small Business | |
| Mather Fueling System Repairs | ENDIST Omaha | Total Small Business | |
| DESC2103C - Bulk Fuel Storage Tanks Phase II, Yokota Air Base, Japan | ENDIST Japan | No set-aside | |
| Vandenberg SFB Tank Inspection | ENDIST Omaha | Service-Disabled Veteran-Owned Small Business |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity