Synopsis - Repair WHCA POL Tanks

Closed Pre-Solicitation Posted

Not the latest version. See the latest solicitation from .

Solicitation number
FA706024R0003
Agency
Responses due
Set-aside
Total Small Business

Opportunity facts

Place of performance
Bolling AFB, District of Columbia 20032, United States

Notice details come from SAM.gov. Updated .

About this opportunity

This pre-solicitation notice seeks design and construction services for repairs to petroleum, oil, and lubricant storage tanks at White House Communications Agency facilities. The Department of the Air Force Headquarters District Washington requires removal and replacement of underground oil-water separators and oil storage tanks at two buildings, installation of new oil-water separators with integral oil storage and alarms, removal of an underground diesel tank to be replaced with above-ground diesel tanks featuring spill protection. The subsequent solicitation will result in a firm-fixed price contract award made to the lowest price technically acceptable offer in accordance with the requirements and Statement of Work to be provided.

The anticipated solicitation is designated for total small business set-aside with a North American Industry Classification System code of 237120 and business size standard of $45,000,000 in average annual receipts. Prospective contractors must register in SAM.gov as the solicitation package will be available there as well as on beta.SAM.gov no fewer than 15 days after this pre-solicitation notice. There is no current incumbent mentioned, however the project involves removal and replacement of approximately 10,000-gallon oil and diesel storage tanks at two WHCA facilities.

Notice text

The project is for the Design and Construction of petroleum, oil, and lubricant (POL) tanks for White House Communications Agency (WHCA). It includes removal of underground Oil-Water Separators in buildings 399 and 408 for WHCA , removal of oil storage tanks, and installation of new Oil-Water Separators with integral oil storage and alarms to alert when oil should be removed.  It also includes the removal of an underground 10,000-gallon diesel tank, hole filled with engineered fill, and platforms built with spill protection for above-ground 10,000 gallon diesel oil tanks.  Lastly, it provides all connections to the tanks and two 250-gallon ready service interior oil tanks with spill prevention measures to include double-walled piping. NOTE: Complete project details shall be provided via the Statement of Work at the time a solicitation is posted.

Files

File Type Posted
SYNOPSIS - Repair WHCA POL Tanks.pdf PDF

Notice history

Notice Type Posted
Repair WHCA POL Tanks Latest solicitation Solicitation
This notice Original Pre-Solicitation

Similar open opportunities

Opportunity Agency Set-aside Responses due
Cleaning, Inspection, and Hazardous Waste Removal for Two 10, 000-Gallon Oil/Water Separators Minneapolis, Minnesota 55450, United States · NAICS 541990 Secretary of the Air Force Total Small Business
WH Ford RTC Fueling System Repairs 42345 · NAICS 237120 ENDIST Omaha Total Small Business
Mather Fueling System Repairs Mather, California 95655, United States · NAICS 237120 ENDIST Omaha Total Small Business
DESC2103C - Bulk Fuel Storage Tanks Phase II, Yokota Air Base, Japan Yokota Air Base, Japan · NAICS 237120 ENDIST Japan No set-aside
Vandenberg SFB Tank Inspection Vandenberg SFB, CA 93437 · NAICS 541990 ENDIST Omaha Service-Disabled Veteran-Owned Small Business

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity