Canceled
Cancelled Solicitation Posted
- Solicitation number
- 36C10X22Q0225
- Agency
-
VA Strategic Acquisition Center Frederick
Headquarters, Department of Veterans Affairs
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 238210 Electrical Contractors and Other Wiring Installation Contractors
- Place of performance
- Hines, Illinois 60141, United States
Notice details come from SAM.gov. Updated .
Notice text
2 versions
Update #2 · Latest ·
Canceled
Update #1 ·
The Contractor shall be responsible to inspect, test, document deficiencies, repair/refurbish, retest, paint, tag, package and reship/reinstall switchgear breakers at HITC. The Contractor shall provide all necessary labor, tools, material, parts, testing equipment, supervision to service switchgear breakers while maintaining energized circuits/no power disruptions to the data center operation. The overall goal of the project is to upgrade the static trips units on the data center related switchgear breakers, perform preventative maintenance on all facility (house) and data center breakers to ensure compliance with NFPA/NEC 70E. The Contractor shall:
- Purchase and install eleven (11) of the Utility Relay Company’s AC PRO II (or equal) static trip units, broken down as follows:
- Five (5) DS-206 switchgear breakers with 120v controls (currently installed and operational).
- Six (6) bench stock DS-206 switchgear breakers (refurbished/benchstock).
- Purchase and install a Monitoring and Control System that is compatible to the static trip units that display, monitor, and log power consumption (Amps/Voltage/KVA) of each breaker and cumulative of the entire system. One unit will be Wi-Fi and internet compatible to the VA system where the user can access it from any VA device. The other unit will be a control device at the system of operation. HMI will be in the switchgear room and also via the web base interface.
- HITC’s existing switch gear breakers are all custom fabricated Square D or Siemens breakers to fit in the Westinghouse frames. The Contractor shall provide a turn-key solution with refurbishing the existing breakers. The reconditioned breakers shall be altered from the existing switchgear frame or settings, which are Westinghouse brand (Eaton). The model numbers are unknown. The vendor shall provide the brand name product listed above, or an “equal” product that meets the followingknown electrical gears:
-
- Siemens, DS-623-Type 3200A-Frame
- Siemens, DS-416-Type 1600A-Frame 1600A
- Siemens, DS-206-Type 800A-Frame 800A
Files
| File | Type | Posted |
|---|---|---|
| 36C10X22Q0225.pdf | ||
| Pre-Quote Site Visit - HITC Switchgear.xlsx | XLSX spreadsheet | |
| 36C10X22Q0225 (Combined Synopsis).docx | DOCX document | |
| ATTACHMENT B - PAST PERFORMANCE QUESTIONNAIRE.pdf | ||
| WAGE DETERMINATION.pdf | ||
| ATTACHMENT A - PAST PERFORMANCE REFERENCES.pdf | ||
| ATTACHMENT C - PRICE SCHEDULE .xlsx | XLSX spreadsheet | |
| ATTACHMENT 1 - HITC Main Electrical Drawings.pdf |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity