Smart High Primary Injection Test System DLA Product Test Center, VTA

Closed Pre-Solicitation Posted

Not the latest version. See the latest solicitation from .

Solicitation number
SP4706-24-Q-0039
Agency
Responses due
Set-aside
Total Small Business

Opportunity facts

Place of performance
Columbus, Ohio 43213, United States

Notice details come from SAM.gov. Updated .

About this opportunity

The Defense Logistics Agency (DLA) is seeking to procure a Smart High Current Primary Injection Test System to be used by the DLA Product Test Center in Columbus, Ohio. The contractor shall provide a new, non-refurbished test system capable of outputting up to 2,000A (expandable to 7,478A), with adjustable output ranges, digital displays, communication ports, and the ability to test low-voltage molded-case circuit breakers up to 225A. Key requirements include a Smart Touch View Interface, automated testing software, a 24-month extended warranty, and various accessories such as cables and software licenses. The system must be delivered within 10 weeks of contract award.

This procurement is set aside for small businesses. The estimated value of the contract is not provided. The government has attached technical specifications and a statement of work to the pre-solicitation notice. Proposals are due by July 17, 2024, and the NAICS code is 334516 (Analytical Laboratory Instrument Manufacturing) with a PSC of 6640 (Laboratory Equipment And Supplies).

Notice text

I. The contractor shall provide all labor, materials, tools, transportation, supplies, supervision, etc. (except as noted), necessary to provide all components for a Smart High Current Primary Injection Test System used to test low-voltage molded-case circuit breakers up to a rating of 225A to the Defense Supply Center Columbus (DSCC), Columbus, Ohio. The salient characteristics of the Smart High Current Primary Injection Test System are as listed below:


A. Smart High Current Primary Injection Test System with support equipment and with the following salient characteristics:
1. Shall be new, not refurbished.
2. Shall be supplied with Operating manual.
3. Shall be powered by standard US 115V, 15A AC power outlet.
4. Shall be able to output up to 2,000A and be expendable to 7478A if running 4 units in parallel.
5. Shall have three continuously adjustable output ranges: 25 to 500A at 3.5 V MAX, 6.25 to 125A at 14V MAX and 1.25 to 25A at 70V MAX.
6. Shall have a 5-digit auto ranging ammeter display ranging from 1.0000A to 99.999 kA with an accuracy of RMS pulse +/- 1.5% of reading or +/- 0.075A.
7. Shall have a 5-digit auto ranging voltameter display ranging from 0.01 to 600.00V with an accuracy of +/- 1%.
8. Shall have a 5-digit auto ranging timer display ranging from 0.001 to 99999 seconds with an accuracy of +/- 1%.
9. Shall have two ethernet and two USB 2.0 communication ports.
10. Shall be a smart high current primary injection test system for all forms of high current testing required in a substation, including testing overcurrent relays, circuit breakers, motor overloads and current transformers.
11. Shall be Designed for switchgear commissioning, circuit breaker, CT commissioning, ground grid and relay testing
12. Shall have the ability to perform high current commissioning tests as well as test low-voltage molded-case circuit breakers up to a rating of 225A.
13. Shall have software that includes thousands of circuit breaker curve TCC curves.
14. Shall have the ability to turn on at the current zero crossing every time for any load by automatically adjusting the output firing angle.
15. Shall be able to execute automated test programs from a laptop or manually controlled from a Smart Touch View Interface.
16. Shall include a Smart Touch View Interface that has a simplified touch screen input for manual control.
17. Shall include fuse, circuit breaker and overload protective devices to be incorporated in the system.
18. Shall be provided with software that allows for automated testing, report generation and maintenance record keeping of all primary injection and low voltage circuit breaker tests.
19. Shall have software that includes thousands of circuit breaker curve TCC curves.
20. Shall be able to all breaker parameters including: long time pick-up, long time timing, short time pick-up, short time timing, instantons pick-up, ground fault pick-up and ground fault timing.
21. Shall be able to record up to ten trip/ reclose operations with each trip current, trip time and reclose time recorded.
22. Shall have: a Certificate of Calibration and a 24 Month Extended Warranty.

B. Required Upgrades and Accessories - Brand Name or Equal:
1. Shall at a minimum have: Included Accessories: All necessary electrical cables, communication cables to install and operate machine.
2. Shall be provided with a Smart Touch View Interface that uses a stand ethernet cable and PoE operation, include non-volatile built-in data storge for saving tests and test results and have two USB ports for transferring test results.
3. Shall include the PowerDB Pro Licenses, SQL Upgrade, and purchases options support and maintenance for a period of one year from the date of delivery of the equipment.


C. Place of Performance
The instrument shall be delivered to:
Defense Supply Center Columbus
300 North James Road, Bldg 17-3
Mark for: DLA Product Test Center, Bldg 11-7 (TE Lab)
Attn: Jeremiah L. Jones (jeremiah.l.jones@dla.mil / 614-692-8955)
Columbus, Ohio 43213


D. Travel (if applicable)
N/A


E. Invoicing
Payment of invoices will be accomplished by payment through the Defense Finance and Accounting Service. Invoices will be submitted to the Wide Area Workflow (WAWF) system in accordance with DFARS 252.232-7003 Electronic Submission of Payment Requests and Receiving Reports and DFARS 252.232-7006 Wide Area Workflow Payment Instructions within 10 workdays after the conclusion of each training session.

F. WAWF Acceptance DODAAC#
1. TA Lab is SL0700.

G. Other Requirements:
1. Delivery: 10 Weeks from date of the award.
2. Contractor shall give notification to Jeremiah L. Jones (jeremiah.l.jones@dla.mil /614-692-8955)
when the instrument is ready to be delivered.
3. All shipping costs are to be included in the contracted price.
4. The instrument shall be delivered to:
Defense Supply Center Columbus
300 North James Road, Bldg 17-3
Mark for: DLA Product Test Center, Bldg 11-7 (TE Lab)
Attn: Jeremiah L. Jones (jeremiah.l.jones@dla.mil / 614-692-8955)
Columbus, Ohio 43213


5. Invoices shall be submitted through Wide Area Workflow (WAWF), See DFARS Clause 252.232-7006 Wide Area Workflow Payment Instructions for detailed instructions on how to submit invoices.

Files

File Type Posted
CIRCUIT BREAKER TechSpecsSOW.pdf PDF
Tech Specs CIRCUIT BREAKER TESTER.pdf PDF

Notice history

Notice Type Posted
Smart High Primary Injection Test System Latest solicitation Solicitation
This notice Original Pre-Solicitation

Similar open opportunities

Opportunity Agency Set-aside Responses due
Test bench, digital NAICS 334515 Land and Maritime Total Small Business
Multimeter NAICS 334412 Land and Maritime No set-aside
Lead set, test NAICS 334515 Land and Maritime Service-Disabled Veteran-Owned Small Business
Test device, interface United States · NAICS 334515 Land and Maritime No set-aside
Case, electrical-ELE United States · NAICS 33599 Land and Maritime No set-aside

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity