Skybridge Test Rail Anchors
Closed Solicitation Posted
- Solicitation number
- 36C26025Q0144
- Agency
- Veterans Integrated Service Network 20 Veterans Health Administration, Department of Veterans Affairs
- Responses due
- Set-aside
- Service-Disabled Veteran-Owned Small Business
Opportunity facts
- NAICS code
- 541350 Building Inspection Services
- PSC
- H999 Other Qc/Test/Inspect- Miscellaneous
- Place of performance
- Portland, Oregon 97239, United States
- Points of contact
-
- Colleen M Nicholson colleen.nicholson@va.gov (360) 553-7650
- Andrew Barrow andrew.barrow@va.gov
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 20 is seeking a Service-Disabled Veteran-Owned Small Business to conduct comprehensive testing of rail anchors for a skybridge window washing system at the VA Portland Health Care System. The solicitation requires testing 128 attachment points along the skybridge track, with an initial proposed test load of 5,000 lbs to validate the system's structural integrity for supporting a bosun chair used in window washing operations. Contractors must be registered in SAM.gov and possess the capability to perform detailed structural testing, with proposals due by March 21, 2025 at 4:00 PM PDT. Questions from potential bidders were required to be submitted by March 7, 2025. The contract will be a Firm-Fixed-Price arrangement administered by Network Contracting Office 20 in Vancouver, Washington, with the final test results requiring certification and stamping by a structural engineer.
The solicitation is a 100% Service-Disabled Veteran-Owned Small Business (SDVOSB) set-aside under NAICS category 541350 (Building Inspection Services) with a size standard of $11.5 million. The place of performance is located in Portland, Oregon, specifically at the VA Portland Health Care System campus, with the skybridge connecting to the Oregon Health & Science University campus. The project involves testing rail anchors on a 10,019 GSF skybridge structure situated at 660' elevation, with access to the track system possible through a roof hatch in the elevator lobby or via a hinged window on the third floor. While no specific incumbent or current contractor is mentioned, the project appears to be part of a larger campus infrastructure improvement initiative. The technical requirements are detailed across six architectural drawings that provide comprehensive specifications for the rail anchor testing and installation.
Notice text
2 versions
Update #2 · Latest ·
Test rail anchors (track for window washing) to 5000 lbs. The track runs along the top of the windows on both sides of the skybridge. The purpose of this track is to support a bosun chair for a person to wash the windows.
Attachment 1 Drawing 1
Attachment 2 Drawing 2
Attachment 3 Drawings 3
Attachment 4 Drawings 4
Attachment 5 Drawings 5
Attachment 6 Drawings 6
36C26025Q0144
Update #1 ·
Test rail anchors (track for window washing) to 5000 lbs. The track runs along the top of the windows on both sides of the skybridge. The purpose of this track is to support a bosun chair for a person to wash the windows.
Attachment 1 Drawing 1
Attachment 2 Drawing 2
Attachment 3 Drawings 3
Attachment 4 Drawings 4
Attachment 5 Drawings 5
Attachment 6 Drawings 6
Attachments
| File | Type | Posted |
|---|---|---|
| 36C26025Q0144 0001.docx | DOCX document | |
| Attachment 6 Drawing 6.pdf | ||
| Attachment 2 Drawing 2.pdf | ||
| S02 RFQ 36C26025Q0144.pdf | ||
| Attachment 5 Drawing 5.pdf | ||
| Attachment 1 Drawing 1.pdf | ||
| Attachment 4 Drawing 4.pdf | ||
| Attachment 3 Drawing 3.pdf |
Notice history
| Notice | Type | Posted |
|---|---|---|
| Skybridge Test Rail Anchors | Solicitation | |
| Skybridge Test Rail Anchors | Pre-Solicitation |
On GovTribe
Work this opportunity on GovTribe
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity