Sawyer Creek Culvert

Closed Solicitation Posted

Solicitation number
W911S226U3442
Agency
Responses due
Set-aside
Total Small Business

Opportunity facts

Place of performance
T-84 1st St West Fort Drum, NY 13602 13602

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of the Army Materiel Command Mission and Installation Contracting Command Fort Drum seeks a box culvert for Sawyer Creek, with proposals due June 22, 2026. The procurement is a Total Small Business set-aside.

Place of performance is 84 1st St W, Fort Drum, NY 13602. The culvert specifications include a 5-foot wide by 6-foot high by 51.7-foot length box culvert comprising eight sections, cutoff walls at two culvert ends and four wingwalls, four L-shaped cantilever wingwalls 8 feet long, two headwalls 1 foot wide by 1 foot high at each end section, and neoprene gaskets installed on each box section prior to delivery. The culvert must achieve HL-93 Live Load Rating, with Class 100 Tracked and Class 120 Wheeled ratings in accordance with UFC 3-310-08. The culvert skew angle with the road is 24 degrees. All drawings and submittals must be stamped by a professional engineer licensed in New York with supporting engineering calculations provided. The NAICS code is 331210, Iron and Steel Pipe and Tube Manufacturing from Purchased Steel. The PSC code is 5450, Miscellaneous Prefabricated Structures. Exterior waterproofing is by others. Level 1 black bar reinforcing is carried.

Notice text

5? wide x 6? high x 51.7? length Box Culvert to include: Approximately (51.7) Lineal feet of 5? (span) x 6? (rise) I.D. of Box Culvert (8sections). Cutoff Walls for (2) Culvert ends and (4) wingwalls. (4) L-shaped cantilever wingwalls 8?long. (2) Headwalls, one at each end 1? wide x 1? high on each end section. Neoprene gaskets will be installed on each box section prior to delivery. Exterior waterproofing by others. Level 1 black bar reinforcing carried. HL-93 Live Load Rating assumed (NY PE stamp w/ supporting Calculations provided). Class 100 Tracked and Class 120 Wheeled in accordance with UFC 3-310-08 in attached PDF. Skew angle of the culvert with the road will be 24 degrees. Drawings/submittals stamped by a PE licensed in NY with supporting engineering.

Similar open opportunities

Opportunity Agency Set-aside Responses due
Construction material PBO, 2/75 Ranger RegimentBLDG 3463, 3rd Division Dr./Mastin Ave.Jblm, WA 98433 98433 · NAICS 327390 MICC Fort Drum Total Small Business
Steel mechanical tubing Rock Island, Illinois 61299 · NAICS 331210 MICC Fort Drum Total Small Business
8 inch eave beam, C purlin, Z purlin 1 C Tree Rd McAlester Ok Mcaap 74501 · NAICS 331210 MICC Fort Drum Total Small Business
W6x25 II BEAM 20 FT LONG, W10x19 I BEAM 25 FT LONG 1 C Tree Rd McAlester Ok Mcaap 74501 · NAICS 331210 MICC Fort Drum Total Small Business
Concrete Urn liners 1 Memorial DriveArlington, VA 22211 22211 · NAICS 327390 MICC Fort Drum Total Small Business

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity