Roof Replacement/Repair
Closed Pre-Solicitation Posted
- Solicitation number
- 13Q0002
- Agency
-
Edison Job Corps Center
Office of Job Corps, Department of Labor
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 238160 Roofing Contractors
- PSC
- Not on record
- Place of performance
- 500 Plainfield Avenue Edison, New Jersey 08817 Edison, New Jersey 08817, United States
Notice details come from SAM.gov. Updated .
Notice text
2 versions
Update #2 · Latest ·
All bids shall be recieved by COB June 21, 2013 at 5:00pm Eastern Time.
Please email for the bid pachage.
THIS IS A SUBCONTRACTING OPPORTUNITY
SCOPE OF WORK
Subcontractor shall provide the following:
Subcontractor shall provide all labor; materials to complete this scope of work here-in at Edison Job Corps Center.
There will be a scheduled walk thru on May 31, 2013 at 9:00am for any proposed bidder.
The existing single ply main roof of the cafeteria is deteriorated and leaking.
SOW:
A roofing consultant should be obtained to make recommendations, coordinate the installation, and inspect the phases of the installation. Remove the existing single ply roof. Install 13,100 SF of fully adhered TPO roof system with polyisocyanurate insulation and set in mastic recommended by the manufacturer. The membrane should be a strength of 35 kN/m minimum. All materials shall be kept warm if delivered in cold weather. Provide flashing as required. Remove 2 existing scuppers and install new. Install 4 new 6" roof drains connected to existing pipes. Provide walk way pads to existing units. Provide 20 year NDL manufacturer warranty.
Update #1 ·
All bids shall be recieved by COB June 21, 2013 at 5:00pm Eastern Time.
Please email for the bid pachage.
THIS IS A SUBCONTRACTING OPPORTUNITY
SCOPE OF WORK
Subcontractor shall provide the following:
Subcontractor shall provide all labor; materials to complete this scope of work here-in at Edison Job Corps Center.
There will be a scheduled walk thru on May 31, 2013 at 9:00am for any proposed bidder.
The existing single ply main roof of the cafeteria is deteriorated and leaking.
SOW:
A roofing consultant should be obtained to make recommendations, coordinate the installation, and inspect the phases of the installation. Remove the existing single ply roof. Install 13,100 SF of fully adhered TPO roof system with polyisocyanurate insulation and set in mastic recommended by the manufacturer. The membrane should be a strength of 35 kN/m minimum. All materials shall be kept warm if delivered in cold weather. Provide flashing as required. Remove 2 existing scuppers and install new. Install 4 new 6" roof drains connected to existing pipes. Provide walk way pads to existing units. Provide 20 year NDL manufacturer warranty.