Reroute Power Supple at the Phoenix Rearing Facility

Closed Solicitation Posted

This opportunity was awarded. See its 2 award notices in the notice history.

Solicitation number
12639526Q0224
Agency
Responses due
Set-aside
Total Small Business

Opportunity facts

Place of performance
Phoenix, Arizona 85040, United States

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of Agriculture's Animal and Plant Health Inspection Service seeks a licensed electrician to remove and reroute a 2-inch power supply conduit at the Phoenix Rearing Facility, eliminating a tripping hazard and rerouting 240-volt 3-phase supply power and control wires overhead to a mixing blender, with offers due August 14 at 12:00 PM Central Time. This is a Total Small Business Set-Aside with an estimated magnitude under $25,000.

Place of performance is 3645 East Chipman Road, Phoenix, Arizona 85040. The breaker panel resides in an adjacent room; the contractor must run new conduit through a wall to the mixing blender and control wire conduit approximately 10 feet from an existing control panel. The facility contains fine dust particles from wheat and soy that pose fire hazards; the contractor must use rigid conduit with sealed, tight connections to prevent electrical arcing and must backfill and seal all floor holes where conduits are removed. The environment includes a dust collection system. Work must be completed within 30 days of Notice to Proceed, with permitted working hours 6:00 AM to 4:00 PM Monday through Friday. Prime contractors must use Arizona-licensed C-11 or CR-11 electrical subcontractors. The contractor must obtain and pay for any required City of Phoenix electrical permits and comply with all federal, state, and local electrical codes. Prevailing wage requirements apply under FAR and AGAR clauses; a wage determination for Maricopa County, Arizona (AZ20260001) governs electrician and laborer rates.

NAICS code is 238210. A mandatory site visit occurred July 23, 2026. Questions were due July 29 at 12:00 PM Central Time. Amendment 0002, effective August 5, corrected the offer deadline to August 14 and posted site visit sign-in documentation and questions and answers. Award will go to the lowest price, technically acceptable offer. Offerors must hold prices firm for 90 days from the quotation deadline and acknowledge receipt of all amendments in their submission.

Notice text

2 versions

Update #2 · Latest ·

Reroute Power Supply


POC: Erick Plamann, Contract Specialist, erick.plamann@usda.gov


a licensed electrician remove the 2 conduit tripping hazard and reroute the supply power and control wires overhead to the mixing blender. The breaker panel for the 240-volt 3 phase supply power is located in the next room where the electrician will
have to run new conduit through a wall to the mixing blender. The control wire panel is located within 10 feet from the mixing blender. We prefer that the electrician uses rigid conduit and seals all connections to prevent electrical arching. We do
have fine dust particles from wheat and soy which can become highly flammable. The kitchen possesses a dust collecting system which gathers most of the dust particles.


NAICS Code: 238210


This is being solicited 100% Small Business


Magnitude: Under $25,000

Site Visit
Date: 23 July 2026
Time: 10:00 AM
Location: 3645 E. Chipman RD, Phoenix AZ 85040
POC: Marvin Draper
POC Email: marvin.draper@usda.gov

All question must be emailed (no other means will be accepted) to erick.plamann@usda.gov no later than 12:00 PM Central Time on 7/29/0226.


All offers must be emailed (no other means will be accepted) to erick.plamann@usda.gov no later than 12:00 PM Central Time on 8/14/0226.

Update #1 ·

Reroute Power Supply


POC: Erick Plamann, Contract Specialist, erick.plamann@usda.gov


a licensed electrician remove the 2 conduit tripping hazard and reroute the supply power and control wires overhead to the mixing blender. The breaker panel for the 240-volt 3 phase supply power is located in the next room where the electrician will
have to run new conduit through a wall to the mixing blender. The control wire panel is located within 10 feet from the mixing blender. We prefer that the electrician uses rigid conduit and seals all connections to prevent electrical arching. We do
have fine dust particles from wheat and soy which can become highly flammable. The kitchen possesses a dust collecting system which gathers most of the dust particles.


NAICS Code: 238210


This is being solicited 100% Small Business


Magnitude: Under $25,000

Site Visit
Date: 23 July 2026
Time: 10:00 AM
Location: 3645 E. Chipman RD, Phoenix AZ 85040
POC: Marvin Draper
POC Email: marvin.draper@usda.gov

All question must be emailed (no other means will be accepted) to erick.plamann@usda.gov no later than 12:00 PM Central Time on 7/29/0226.


All offers must be emailed (no other means will be accepted) to erick.plamann@usda.gov no later than 12:00 PM Central Time on 8/12/0226.

Files

File Type Posted
C-1_Amendment 0002 Q and A.pdf PDF
sign in sheet for power reroute site walk 072326.pdf PDF
12639526Q0224 A0002.pdf PDF
C04_Attachment 1 SOI v2.pdf PDF
12639526Q0224 A0001.pdf PDF
C04_Attachment 3 Wage Determination.pdf PDF
C04_Attachment 2 SOW.docx DOCX document
C04_Attachment 1 SOI.pdf PDF
C04_12639526Q0224.pdf PDF

Notice history

Notice Type Posted
Reroute Power Supple at the Phoenix Rearing Facility Latest Award Notice
Reroute Power Supple at the Phoenix Rearing Facility Award Notice
This notice Latest solicitation Solicitation

Similar open opportunities

Opportunity Agency Set-aside Responses due
Fernan Ranger Station lift station electrical repair Coeur d Alene, Idaho, United States · NAICS 238210 Region 1 - Northern Region Total Small Business

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity