Request for information for handheld gas analyzers
Closed Pre-Solicitation Posted
- Solicitation number
- N6133126SNQ40
- Agency
-
Naval Sea Systems Command
Department of the Navy, Department of Defense
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 334516 Analytical Laboratory Instrument Manufacturing
- PSC
- 6630 Chemical Analysis Instruments
- Place of performance
- Panama City Beach, Florida, United States
Notice details come from SAM.gov. Updated .
About this opportunity
The Naval Surface Warfare Center, Panama City Division is issuing a Request for Information on handheld gas analyzers to support confined space entry and post-fire atmospheric recovery aboard naval vessels, with responses due by September 30, 2026. This is a pre-solicitation RFI (N6133126SNQ40) with no anticipated set-aside.
NSWC.PCD requires highly portable, self-contained units weighing under 5 pounds that deploy in under 3 minutes and simultaneously detect and monitor oxygen, lower explosive limit, carbon monoxide, hydrogen sulfide, and volatile organic compounds. To minimize shipboard maintenance footprints, the equipment must support an extended calibration-free interval of at least 12 months and feature simplified, rapid field-sensor replacement capability. The command seeks to address immediate damage control needs with existing commercial products meeting these operational and maintenance specifications. Performance is aboard naval vessels. The opportunity is classified under NAICS 334516 (Analytical Laboratory Instrument Manufacturing) and PSC 6630 (Chemical Analysis Instruments).
Notice text
The Naval Surface Warfare Center, Panama City Division (NSWC.PCD) requests information on existing items such as handheld gas analysis (gas analyzers) to support confined space entry and post-fire atmospheric recovery aboard shipboard fire. To meet immediate damage control needs, the command requires highly portable, self-contained units weighing under 5 lbs that can be deployed in under 3 minutes and simultaneously detects/monitor O2, LEL, CO, H2S, VOC. Furthermore, to minimize shipboard maintenance footprints, the ideal solution must support an extended calibration-free interval of at least 12 months and feature a simplified, rapid field-sensor replacement process.
Files
| File | Type | Posted |
|---|---|---|
| HandHeldGasAnalyzer_SourcesSought_12August2026.RFI.docx | DOCX document |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Air sampler | Naval Supply Systems Command | Total Small Business | |
| Detector kit, gas | Land and Maritime | Total Small Business | |
| Preventative Maintenance Gas Detection System (Re-Bid) | Naval Air Systems Command | Total Small Business | |
| Sensor, smoke detect, in repair/modification of | Naval Supply Systems Command | No set-aside | |
| Sources Sought for (ICP-OES) Spectrometer System with an Autosampler | Naval Supply Systems Command | No set-aside |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity