Replacement Rooftop A/C Units B104
Closed Pre-Solicitation Posted
A newer solicitation was posted. See the latest solicitation from .
- Solicitation number
- FA527025R0034
- Agency
- Pacific Air Forces Air Force, Department of Defense
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 238220 Plumbing, Heating, and Air-Conditioning Contractors
- PSC
- Z1NZ Maintenance Of Other Utilities
- Place of performance
- Building 104 (Switchgear and Generator Rooms), Buckner Communication Site, Okinawa, Japan
- Points of contact
-
- Moriah Clark moriah.clark.2@us.af.mil (634) 634-3079
- Nicholas Cripe nicholas.cripe@us.af.mil (989) 612-0910
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of the Air Force Pacific Air Forces is seeking contractors to replace rooftop air conditioning units for Building 104 at the Buckner Communication Site in Okinawa, Japan. This project involves the complete removal and installation of new AC systems, ventilation systems, and roofing systems specifically for the Switchgear and Generator Rooms within the facility. The work is critical due to existing leaks in the deteriorated HVAC system that pose serious risks to the facility's equipment, requiring immediate attention to ensure operational safety. Contractors must address hazardous materials concerns, as the existing building and roof contain asbestos and lead TCLP materials that require safe removal procedures. All design and construction activities must strictly comply with Federal Acquisition Regulation specifications and the technical requirements outlined in the Request for Proposal, which establish minimum design and construction quality standards. This pre-solicitation notice was posted on July 22, 2025, with a response deadline of August 7, 2025.
This opportunity falls under NAICS code 238220 for Plumbing, Heating, and Air-Conditioning Contractors and has no set-aside designation, making it available to all qualified contractors. The project is classified under PSC code Z1NZ for Maintenance of Other Utilities, indicating its focus on facility infrastructure maintenance and improvement. The notice does not specify current contractors or incumbents for this particular facility maintenance work. No specific contract value, budget range, or detailed timeline for completion is provided in this pre-solicitation phase. The scope encompasses comprehensive HVAC system replacement along with associated roofing work, suggesting a substantial infrastructure project requiring specialized expertise in both mechanical systems and hazardous material remediation.
Notice text
This project is to remove and install new AC system, ventilation system and roofing system building 104 Switchgear and Generator Rooms, Buckner Communication Site, Okinawa, Japan. Design and construction shall comply with the specifications and requirements contained in this Request for Proposal RFP. The design and technical criteria contained and cited in this FAR establishes the minimum standards for design and construction quality. Replace all existing deteriorated HVAC system. There are concerns that leaks could cause serious damage to the facility?s equipment. The purpose of this work is to stop the leakage and ensure the safety of facility equipment. The existing building and roof contains asbestos and lead TCLP material that must be safely removed. All design and construction activities shall strictly comply with the specifications and requirements set forth in this RFP, which establish the minimum design and technical quality standards. All the work required above this contract including but not limited to.