Replace Roofing - Building 66 & 67
Closed Pre-Solicitation Posted
This opportunity was awarded. See the award notice from , or the latest solicitation from .
- Solicitation number
- W519TC-24-R-2001
- Agency
- ACC Rock Island Army Contracting Command, Department of Defense
- Responses due
- Set-aside
- Total Small Business
Opportunity facts
- NAICS code
- 238160 Roofing Contractors
- Place of performance
- Rock Island, Illinois 61299, United States
Notice details come from SAM.gov. Updated .
About this opportunity
The Army Contracting Command - Rock Island is seeking to replace the roofs on Buildings 66 & 67 at the Rock Island Arsenal in Rock Island, Illinois. The scope of work includes removing the existing metal seam panel roofs and accessories and installing new stamped metal shingled roof systems with spray-on foam insulation. Roof replacements aim to prevent water leakage, reduce energy usage, and meet energy reduction goals. Questions are due by November 6, 2023, with proposals evaluated on technical qualifications.
This requirement is set aside only for total small businesses. The predominate NAICS code is 238160 for roofing contractors and the predominate PSC code is R499 for repair and alteration of non-residential structures and buildings. The project value is estimated between $1,000,000 to $5,000,000 and will replace approximately 45,240 square feet of roofing across the two buildings. Spray-on foam insulation will provide an R-63 value and fire separation will be required.
Notice text
The Army Contracting Command - Rock Island is issuing this pre-solicitation synopsis for W519TC-24-R-2001.
This pre-solicitation synopsis is notice regarding the Replace Roofing - Building 66 & 67 on the Rock Island Arsenal, Rock Island, IL.
This requirement will be a 100% total small business set-aside.
This is a notice that a solicitation is anticipated to be forth coming and will have all necessary documents, including scope of work.
IAW FAR 36.204(f), the magnitude of this project is between $1,000,000.00 and $5,000,000.00.
The scope of this project consists of the repair of the failed roof on Building B66 ± 45,240 square feet (s.f.) that include a small portion of Building B67 to prevent rainwater from leaking into the buildings and causing damage to the structure and items inside the buildings. Repair includes removing the existing metal seam panel roof to the deck, ceiling battens, roof hatches, skylights, gutters and downspouts, repair any damage decking and re-roof with a new stamped metal shingled roofing system with a ceramic coated granule protective coating and complete with all related accessories designed to mimic the appearance of slate roofing. The scope includes to insulate the underside of Building B66 and portion of B67 roof with a spray-on foam insulation to provide an R-63 insulation value necessary to reduce energy usage and meet energy reduction goals including re-support the existing fire sprinklers pipes. The foam insulation shall be covered with a film to provide code required minimum fire separation. Included in the work will be the replacement of (3) existing selected roof hatches, in-fill removed skylights, provide new roof curbs, flashing, counter flashing, downspout, and gutters as required by manufacturer and to match existing building appearance.
Notice history
| Notice | Type | Posted |
|---|---|---|
| Replace Roofing - Building 66 & 67 | Award Notice | |
| Replace Roofing - Building 66 & 67 | Solicitation | |
| Replace Roofing - Building 66 & 67 | Pre-Solicitation | |
| Replace Roofing - Building 66 & 67 | Pre-Solicitation |