Replace Heating and Cooling Coil at Building No. 457, Camp Zama (CZ)
Closed Pre-Solicitation Posted
- Solicitation number
- FA520926Q039A
- Agency
-
Pacific Air Forces
Air Force, Department of Defense
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 811310 Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance
- Place of performance
- Zama Kanagawa Japan
- Points of contact
Notice details come from SAM.gov. Updated .
About this opportunity
Pacific Air Forces intends to solicit a firm-fixed-price service contract to replace a heating and cooling coil at Building No. 457, Camp Zama, with an anticipated award date of 30 September 2026. The procurement carries no set-aside and responses are due by 10 August 2026.
Work will be performed in its entirety in Japan. The successful offeror must hold a valid Japanese CAGE code and possess active licenses to perform work in Japan. Personnel qualifications are mandatory throughout the contract term: at least one Plumbing Technician certified grade 2 or above and at least one Electrician licensed 2nd Class or higher, both Japanese certifications.
The contractor shall supply all necessary personnel, supervision, management, tools, equipment, transportation, materials, and other items required to complete the work in accordance with the Performance Work Statement, commercial standards and practices, and the manufacturer's specifications. The scope is categorized under NAICS 811310 (Commercial and Industrial Machinery and Equipment Repair and Maintenance) and PSC Z2JZ (Repair or Alteration of Miscellaneous Buildings).
Notice text
This notice is prepared IAW RFO FAR 5.1 and 12.201-1(c)(2). THIS NOTICE IS NOT A REQUEST FOR QUOTATIONS.
The Government intends to solicit this requirement directly from suppliers IAW RFO FAR 12.201-1(c)(2) for firm-fixed price service contract for Repair Fire Alarm System at Bldg.500, Camp Zama (CZ), U.S Army Garrison Japan. Anticipated award date is around 30 Sep 2026 (subject to change).
Description of Services: The contractor shall provide all necessary personnel, supervision, management, tools, equipment, transportation, materials and any other items or services necessary to perform to replace Heating and Cooling Coil at Building No. 457, Camp Zama (CZ). The contractor shall perform in accordance with (IAW) this Performance Work Statement (PWS), commercial standards and practices, and the manufacturer’s specifications.
Note 1: This project will be performed in its entirety in the country of Japan. The successful offeror must have valid licenses to perform work in the country of Japan. Offerors must have a Japanese CAGE code.
Note 2: Personnel Qualifications. The contractor shall be responsible for their employees have the following current and valid professional Japanese certification for the entire life of this contract.
- Plumbing Technician, grade 2 or above (2級配管技能士以上)
- Electrician License, 2nd Class License or Higher (電気工事士2種以上)
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| DCDO - HVAC Maintenance | Pacific Air Forces | No set-aside | |
| Combined Synopsis/Solicitation Notice: Maintenance of Commissary Refrigeration Systems and Repair of Refrigeration, Heating, Ventilation, and Air Conditioning Systems (HVAC) at Hario and Sasebo, Japan | ENDIST Japan | No set-aside | |
| AFHC Repair Quarters 82 and 86, Camp Zama, Japan | ENDIST Japan | No set-aside | |
| Replace HVAC Rooftop Units at Building 2275 | Army National Guard | No set-aside | |
| Replace DSN-HDD Generator for 78th Signal Battalion, Camp Zama, Japan. | Pacific Air Forces | No set-aside |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity