The Naval Surface Warfare Center Port Hueneme Division is soliciting repair services for Universal Power Supply (UPS) units under contract N6339425Q4032. The procurement involves repairing 5 Energy Technology, Inc. (ETI) UPS units (Part Number ETI0001-1237, Model ETI0001-S1R-KII/2.0) that support the Tomahawk Weapons Control System program. Contractors must demonstrate technical capability to evaluate and repair UPS units, ensuring they can hold battery discharge at 500 watts for 30 minutes and maintain proper functionality of all lights, alarms, fans, and switches without physical damage. The government will evaluate quotes based on lowest price, technical capability, and past performance, with award made to the lowest-priced, technically acceptable offeror. Quotes are due by June 30, 2025, at 3:00 PM Pacific Standard Time and must be submitted electronically as a PDF to the designated point of contact.

This solicitation is designated as a Women-Owned Small Business (WOSB) set-aside, requiring eligible contractors to meet the specific socioeconomic criteria for participation. Energy Technologies Inc. (ETI) is identified as the Original Equipment Manufacturer of the UPS units and holds proprietary design rights, making them the sole source for new equipment procurement based on their Environmental Qualification Testing certification. The contract structure includes a base period beginning August 2025 and four one-year option periods extending through July 2032, providing a potential seven-year performance timeline. Repairs must be performed at the contractor's facility within the United States, with work supporting critical weapons system operations. The UPS units are specifically designed to provide conditioned 115 VAC power to the PCP (A1) component and include battery packs for orderly shutdown during power loss events.

Notice text

Please see attached Solicitation and J&A for more information on this request.

Files

Notice history

Notice Type Posted
Repair Universal Power Supply (UPS) Award Award Notice
This notice Latest solicitation Solicitation
Repair Universal Power Supply (UPS) Original Pre-Solicitation

Similar open opportunities

Opportunity Agency Set-aside Responses due
Power supply NAICS 335311 Naval Supply Systems Command No set-aside
Preventive/Corrective Maintenance for Government Owned Uninterrupted Power Source System San Diego, California 92136, United States · NAICS 811210 Naval Supply Systems Command Total Small Business
Power supply, in repair/modification of NAICS 335931 Naval Supply Systems Command No set-aside
Power supply NAICS 335931 Naval Supply Systems Command No set-aside
6135--Uninterrupted Power Supply (UPS) Batteries Department of Veterans Affairs Lebanon VA Medical Center Lebanon PA 17042, United States · NAICS 335910 Veterans Integrated Service Network 4 Woman-Owned Small Business

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors