Repair Two 20, 000-Gallon Oily Wastewater Storage Tanks

Closed Solicitation Posted

This opportunity was awarded. See the award notice from .

Solicitation number
N4523A22Q5720
Agency
Responses due
Set-aside
Total Small Business

Opportunity facts

Place of performance
Bremerton, Washington, United States

Notice details come from SAM.gov. Updated .

About this opportunity

This solicitation is seeking offers to repair two 20,000-gallon vertical, cylindrical, aboveground, double-walled oily wastewater storage tanks located at Puget Sound Naval Shipyard that service Oily Wastewater Treatment System Plant 4. The Department of the Navy Naval Supply Systems Command issued this requirement to address holes, pits, leaks, and corrosion damage evident on the tank floors, walls, and components. Offerors must meet standards from API, STI, UL, NFPA for tank construction and NACE certification standards for tank coating. Pricing will be fixed price, with award going to the responsible offeror submitting the lowest priced technically acceptable quote by July 5, 2022.

This is a total small business set-aside with a NAICS code of 238990. The tanks require cleaning, welding repairs, new tank lining installation, replacement of stainless steel guide cables and sensors, and recoating within 90 days of award at the Puget Sound Naval Shipyard in Bremerton, Washington. The solicitation responses will address questions received by June 21st and 28th relating to the scope of work detailed in attachments to the solicitation.

Notice text

2 versions

Update #2 · Latest ·

Q&A#1 is added per questions provided from a vendor and answers received from the customer.  The solicitation closing date remains unchanged.  See Attachment C08.8 Q&A#1 for the questions and answers.

Puget Sound Naval Shipyard (PSNS) has six OWTS plants. Two if the 20,000- gallon vertical, cylindrical, aboveground, double-walled wastewater storage tanks have developed holes, pits, and leaks in the primary tanks. Tank 4C and 4D service OWTS Plant 4  are located at Drydock 4. The holes, pits, and leaks have developed in the tanks due to excessive corrosion. The corrosion is evident by multiple holes, pits, and leaks on the tank walls and floor, separation of the stainless steel sensor guide wires from the carbon steel floor anchors, and damage to the components located inside the tanks such as the high-level alarm and the emergency shut-off valve system. The tank repair shall meet American Petroleum Institute (API), Steel Tank Institute (STI), Underwriters Laboratories Inc. (UL), and National Fire Protection Association (NFPA) standards. The tank coating shall meet National Association of Corrosions Engineers (NACE) certification standards.

See attachment  solicitation C08.0 and attachment  2,  C08.3 PWS for further details.

Update #1 ·

Puget Sound Naval Shipyard (PSNS) has six OWTS plants. Two if the 20,000- gallon vertical, cylindrical, aboveground, double-walled wastewater storage tanks have developed holes, pits, and leaks in the primary tanks. Tank 4C and 4D service OWTS Plant 4  are located at Drydock 4. The holes, pits, and leaks have developed in the tanks due to excessive corrosion. The corrosion is evident by multiple holes, pits, and leaks on the tank walls and floor, separation of the stainless steel sensor guide wires from the carbon steel floor anchors, and damage to the components located inside the tanks such as the high-level alarm and the emergency shut-off valve system. The tank repair shall meet American Petroleum Institute (API), Steel Tank Institute (STI), Underwriters Laboratories Inc. (UL), and National Fire Protection Association (NFPA) standards. The tank coating shall meet National Association of Corrosions Engineers (NACE) certification standards.

See attachment  solicitation C08.0 and attachment  2,  C08.3 PWS for further details.

Files

Notice history

Notice Type Posted
Repair Two 20, 000-Gallon Oily Wastewater Storage Tanks Award Award Notice
This notice Latest solicitation Solicitation
Repair Two 20, 000-Gallon Oily Wastewater Storage Tanks Original Pre-Solicitation

Similar open opportunities

Opportunity Agency Set-aside Responses due
Tank and Parts Washer Cleaning and Desludging Services NAICS 562998 Naval Sea Systems Command Total Small Business
PNSY- Sanitary Tank Cleaning Kittery, Maine 03904, United States · NAICS 562991 Naval Sea Systems Command No set-aside
Dry-Dock: USCG ANT PUGET SOUND (55107) FY27 DD NAICS 336611 — Total Small Business
Tank, fuel, aircraft, in repair/modification of NAICS 336413 Naval Supply Systems Command No set-aside
WWYK240015 - Rehab Tanks 62501E & 62501W Tinker AFB, Oklahoma 73145, United States · NAICS 236220 Air Force Sustainment Center No set-aside

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors