Repair Two 20, 000-Gallon Oily Wastewater Storage Tanks
Closed Solicitation Posted
This opportunity was awarded. See the award notice from .
- Solicitation number
- N4523A22Q5720
- Agency
-
Naval Supply Systems Command
Department of the Navy, Department of Defense
- Responses due
- Set-aside
- Total Small Business
Opportunity facts
- NAICS code
- 238990 All Other Specialty Trade Contractors
- Place of performance
- Bremerton, Washington, United States
Notice details come from SAM.gov. Updated .
About this opportunity
This solicitation is seeking offers to repair two 20,000-gallon vertical, cylindrical, aboveground, double-walled oily wastewater storage tanks located at Puget Sound Naval Shipyard that service Oily Wastewater Treatment System Plant 4. The Department of the Navy Naval Supply Systems Command issued this requirement to address holes, pits, leaks, and corrosion damage evident on the tank floors, walls, and components. Offerors must meet standards from API, STI, UL, NFPA for tank construction and NACE certification standards for tank coating. Pricing will be fixed price, with award going to the responsible offeror submitting the lowest priced technically acceptable quote by July 5, 2022.
This is a total small business set-aside with a NAICS code of 238990. The tanks require cleaning, welding repairs, new tank lining installation, replacement of stainless steel guide cables and sensors, and recoating within 90 days of award at the Puget Sound Naval Shipyard in Bremerton, Washington. The solicitation responses will address questions received by June 21st and 28th relating to the scope of work detailed in attachments to the solicitation.
Notice text
2 versions
Update #2 · Latest ·
Q&A#1 is added per questions provided from a vendor and answers received from the customer. The solicitation closing date remains unchanged. See Attachment C08.8 Q&A#1 for the questions and answers.
Puget Sound Naval Shipyard (PSNS) has six OWTS plants. Two if the 20,000- gallon vertical, cylindrical, aboveground, double-walled wastewater storage tanks have developed holes, pits, and leaks in the primary tanks. Tank 4C and 4D service OWTS Plant 4 are located at Drydock 4. The holes, pits, and leaks have developed in the tanks due to excessive corrosion. The corrosion is evident by multiple holes, pits, and leaks on the tank walls and floor, separation of the stainless steel sensor guide wires from the carbon steel floor anchors, and damage to the components located inside the tanks such as the high-level alarm and the emergency shut-off valve system. The tank repair shall meet American Petroleum Institute (API), Steel Tank Institute (STI), Underwriters Laboratories Inc. (UL), and National Fire Protection Association (NFPA) standards. The tank coating shall meet National Association of Corrosions Engineers (NACE) certification standards.
See attachment solicitation C08.0 and attachment 2, C08.3 PWS for further details.
Update #1 ·
Puget Sound Naval Shipyard (PSNS) has six OWTS plants. Two if the 20,000- gallon vertical, cylindrical, aboveground, double-walled wastewater storage tanks have developed holes, pits, and leaks in the primary tanks. Tank 4C and 4D service OWTS Plant 4 are located at Drydock 4. The holes, pits, and leaks have developed in the tanks due to excessive corrosion. The corrosion is evident by multiple holes, pits, and leaks on the tank walls and floor, separation of the stainless steel sensor guide wires from the carbon steel floor anchors, and damage to the components located inside the tanks such as the high-level alarm and the emergency shut-off valve system. The tank repair shall meet American Petroleum Institute (API), Steel Tank Institute (STI), Underwriters Laboratories Inc. (UL), and National Fire Protection Association (NFPA) standards. The tank coating shall meet National Association of Corrosions Engineers (NACE) certification standards.
See attachment solicitation C08.0 and attachment 2, C08.3 PWS for further details.
Files
Notice history
| Notice | Type | Posted |
|---|---|---|
| Repair Two 20, 000-Gallon Oily Wastewater Storage Tanks | Award Notice | |
| This notice | Solicitation | |
| Repair Two 20, 000-Gallon Oily Wastewater Storage Tanks | Pre-Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Tank and Parts Washer Cleaning and Desludging Services | Naval Sea Systems Command | Total Small Business | |
| PNSY- Sanitary Tank Cleaning | Naval Sea Systems Command | No set-aside | |
| Dry-Dock: USCG ANT PUGET SOUND (55107) FY27 DD | — | Total Small Business | |
| Tank, fuel, aircraft, in repair/modification of | Naval Supply Systems Command | No set-aside | |
| WWYK240015 - Rehab Tanks 62501E & 62501W | Air Force Sustainment Center | No set-aside |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity