Repair interior and exterior, APS facility, building 3623, joint base andrews, maryland

Closed Pre-Solicitation Posted

This opportunity was awarded. See the award notice from , or the latest solicitation from .

Solicitation number
W912DR20B0022
Agency
Responses due
Set-aside
No set-aside

Opportunity facts

Place of performance
JB Andrews Md Usa

Notice details come from SAM.gov. Updated .

About this opportunity

This solicitation is for repair interior and exterior work at Building 3623, Joint Base Andrews in Maryland. The U.S. Army Corps of Engineers, Baltimore District, will seek competitive fixed-price design-build proposals to renovate an existing Air Force Reserve facility. Renovations include sealing cracks, repainting, flooring replacement, restroom renovations including changing layouts, lighting replacements, window and roof repairs, and structural analysis. Proposals are due by July 29, 2020.

There is no set-aside designated for this opportunity. The NAICS code is 236220 for commercial and institutional building construction with a size standard of $39.5 million. The PSC code is Y1JZ. The project value is estimated between $1-5 million. Work must be completed by an unknown contractor and includes temporary office space provision during renovations.

Notice text

2 versions

Update #2 · Latest ·

PROJECT NAME: REPAIR INTERIOR AND EXTERIOR, APS FACILITY, BUILDING 3623, JOINT BASE ANDREWS, MARYLAND

Solicitation No. W912DR20B0022

NAICS Code - 236220

Size Standard - $39,500,000.00

PSC – Y1JZ

Magnitude of Construction - $1,000,000.00 - $5,000,000.00

**THIS PROCUREMENT IS SET-ASIDE FOR WOMEN-OWNED SMALL BUSINESSES ONLY**

This solicitation is expected to be issued on or around August 1, 2020.

                                                                                                                     

PROJECT DESCRIPTION:

The U.S. Army Corps of Engineers, Baltimore District, has been tasked to solicit for and award construction services for the Interior and Exterior APS Facility Building 3623, Joint Base Andrews. The proposed project will be a competitive, firm-fixed-price (FFP), design-build (DB), Invitation for Bid (IFB) procured in accordance with FAR Part 14 Sealed Bidding.

The project is for the renovation of an existing building to support the Air Force Reserve, Joint Base Andrews. The general scope includes seal stress cracks in CMU walls and prep, prime and repaint interior CMU wall surfaces throughout the facility.  Texture prime and repaint interior gypsum wall surfaces throughout facility. Remove vinyl composition tiles and base apply a floor leveler and install VCT where currently installed.  Nonstructural renovation to Men and Women’s restrooms including replacing ceiling tiles and wall finishes, wall and floor tile replacement and new fixtures and furnishings. Reduce Men’s Restroom and enlarge Women’s restroom.  Remove and dispose of water heater and replace with a gas unit in the Mechanical Room. Replace ceiling Bay heaters with ceiling mounted low-intensity tube style infra-red (radiant) 100,000 BTU looped system (natural gas) and corresponding thermostatic controller, natural gas pipe distribution and 120VAC, 60 Hz single phase wiring. Remove and replace security area lighting on the south side of the building with 120-240 volt, 100 watt Pulse - Start metal halide fixtures.  Remove and replace light fixtures Compact Fluorescent Light fixtures in the 1st floor hallway with 120-240 volt, 14 watt LED wall mount fixtures.  Remove and replace light fixtures in the open bay c area with ceiling mounted shop low bay metal halide 120/277 volt. 400-watt light fixtures. Remove damaged brick and install new brick and mortar to match existing. Replace windows and repair roof. Provide temporary office space with utilities and required permitting.  Provide CID with office furniture and facility structural analysis.

Update #1 ·

PROJECT NAME: REPAIR INTERIOR AND EXTERIOR, APS FACILITY, BUILDING 3623, JOINT BASE ANDREWS, MARYLAND

Solicitation No. W912DR20B0022

NAICS Code - 236220

Size Standard - $39,500,000.00

PSC – Y1JZ

Magnitude of Construction - $1,000,000.00 - $5,000,000.00

**Set Aside Yet to Be Determined**

This solicitation is expected to be issued on or around August 1, 2020.

                                                                                                                     

PROJECT DESCRIPTION:

The U.S. Army Corps of Engineers, Baltimore District, has been tasked to solicit for and award construction services for the Interior and Exterior APS Facility Building 3623, Joint Base Andrews. The proposed project will be a competitive, firm-fixed-price (FFP), design-build (DB), Invitation for Bid (IFB) procured in accordance with FAR Part 14 Sealed Bidding.

The project is for the renovation of an existing building to support the Air Force Reserve, Joint Base Andrews. The general scope includes seal stress cracks in CMU walls and prep, prime and repaint interior CMU wall surfaces throughout the facility.  Texture prime and repaint interior gypsum wall surfaces throughout facility. Remove vinyl composition tiles and base apply a floor leveler and install VCT where currently installed.  Nonstructural renovation to Men and Women’s restrooms including replacing ceiling tiles and wall finishes, wall and floor tile replacement and new fixtures and furnishings. Reduce Men’s Restroom and enlarge Women’s restroom.  Remove and dispose of water heater and replace with a gas unit in the Mechanical Room. Replace ceiling Bay heaters with ceiling mounted low-intensity tube style infra-red (radiant) 100,000 BTU looped system (natural gas) and corresponding thermostatic controller, natural gas pipe distribution and 120VAC, 60 Hz single phase wiring. Remove and replace security area lighting on the south side of the building with 120-240 volt, 100 watt Pulse - Start metal halide fixtures.  Remove and replace light fixtures Compact Fluorescent Light fixtures in the 1st floor hallway with 120-240 volt, 14 watt LED wall mount fixtures.  Remove and replace light fixtures in the open bay c area with ceiling mounted shop low bay metal halide 120/277 volt. 400-watt light fixtures. Remove damaged brick and install new brick and mortar to match existing. Replace windows and repair roof. Provide temporary office space with utilities and required permitting.  Provide CID with office furniture and facility structural analysis.

Notice history

Notice Type Posted
Repair interior and exterior, APS facility, building 3623, joint base andrews, maryland Award Award Notice
Repair interior and exterior, APS facility, building 3623, joint base andrews, maryland Latest solicitation Solicitation
This notice Pre-Solicitation
Repair interior and exterior, APS facility, building 3623, joint base andrews, maryland Original Pre-Solicitation

Similar open opportunities

Opportunity Agency Set-aside Responses due
Multiple Award Construction Contract (MACC) Bolling AFB, District of Columbia 20032, United States · NAICS 236210 District Washington No set-aside
Design/Build Maintenance and Repair Army Reserve (MRAR), Area Maintenance Support Activity (AMSA) 21, JBMDL, NJ Joint Base MDL, New Jersey, United States · NAICS 236220 ENDIST Louisville Total Small Business
WWYK260004 - repair structural integrity, B1134, post 34 & north wall Tinker AFB, Oklahoma 73145, United States · NAICS 238190 Air Force Sustainment Center Total Small Business
Joint Base Lewis McChord (JBLM) Multi Domain Task Force (MDTF) Buildings (BLDGs) 3223 and 3224 Joint Base Lewis McChord, Washington, United States · NAICS 236220 ENDIST Seattle Total Small Business