Repair 1 Million Gallon Above Ground Water Tank - FCI Safford

Closed Solicitation Posted

This opportunity was awarded. See the award notice from .

Solicitation number
15B60924Q00000011
Agency
Responses due
Set-aside
No set-aside

Opportunity facts

PSC
5430 Storage Tanks
Place of performance
Safford, Arizona 85546, United States

Notice details come from SAM.gov. Updated .

About this opportunity

The U.S. Department of Justice Bureau of Prisons is seeking a contractor to repair a 1-million-gallon above ground water storage tank located at the Federal Correctional Institution (FCI) in Safford, Arizona. The required repairs include removing the exterior ladder cage and replacing it with two 30-ft wire safety climbs, removing the interior ladder safety climb, performing spot epoxy repairs to the interior ceiling and ladder, installing a hatch gasket, and installing two OSHA confined space entry placards. The storage tank must remain in service during the repair work. The solicitation number is 15B60924Q00000011, and the work must be completed by the selected contractor.

The solicitation is not set aside for a specific type of small business. The NAICS code for this procurement is 238990 - All Other Specialty Trade Contractors, and the PSC code is 5430 - Storage Tanks. No incumbents or current contractors are named, and the award value or budget range is not provided. The place of performance is Safford, Arizona.

Notice text

FCI SAFFORD currently has a 1-million-gallon storage tank that is used to store the water to service the institution. The storage tank is a metal structure and was built in 2008.

In a recent inspection it was noted that the interior tank ceiling showed coating deterioration and flaking.  This tank is equipped with an exterior ladder cage and does not have the wire safety climb.  The interior ladder is in good condition however the safely climb has heavy corrosion. On inspection of the roof hatch there was visible daylight from inside the tank.

The Contractor shall be responsible for completing the following repairs and remedies:

1. Remove exterior ladder cage and replace with (2) 30ft wire safety climb.

2. Remove interior ladder safety climb.

3. Spot epoxy repair to the interior ceiling and ladder.

4. Install a hatch gasket

5. Install (2) OSHA confined space entry placards at the base of ladder, and at roof access hatch. 

******The storage tank will need to stay in service while repairs are being performed.******

Files

File Type Posted
Questions and Answers.pdf PDF
15B60924Q00000011.pdf PDF

Notice history

Notice Type Posted
Repair 1 Million Gallon Above Ground Water Tank - FCI Safford Award Award Notice
This notice Latest solicitation Solicitation

Similar open opportunities

Opportunity Agency Set-aside Responses due
FCC Allenwood - Repair Ground & Elevated Water Tanks - FCC Allenwood, Pennsylvania 17810, United States · NAICS 238220 BOP Field Acquisition Office No set-aside
Replace Water Tanks FCI Marion Marions, Illinois Illinois 62959, United States · NAICS 238220 BOP Field Acquisition Office Total Small Business

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity