Regulated Med Waste Storage Container
Awarded Award Notice Posted
- Solicitation number
- W9114F-17-T-0041
- Agency
- Medical Command Department of the Army, Department of Defense
- Awarded
- to Denios-Ag
- Set-aside
- No set-aside
Opportunity facts
- Contract number
- W9114F-17-P-0039 Federal contract award
- NAICS code
- 562112 Hazardous Waste Collection
- PSC
- Not on record
- Place of performance
- Stuttgart Army Health Clinic 2300 Bldg Stuttgart Germany 70569 Stuttgart, Non-U.S. 70569 Germany
Notice details come from SAM.gov. Updated .
Notice text
2 versions
Update #2 · Latest ·
Added: Apr 12, 2017 8:09 am
The purpose of this amendment is to make the following changes:
i. remove the wording from CLIN 0002 "Removal of the container
ii reword technical factor 6 original: MFG will provide installation of new container and removal
of old container to New: MFG will provide installation of new container.
See attached Amendment to Soliciation
Update #1 ·
Added: Mar 30, 2017 3:09 am
CLIN 0001
Regulated Med Waste Storage Container
FFP
Fire-Rated Storage Container (For Outside Storage).
Requirements must Include:
Frame construction made of sand blasted sections
Roof and side walls must be made of fire resistant casing (EI 120) with fire
protection for inside and outside.
Color
Outside paint container RAL 9002 (Grey white)
Inside paint container RAL 9002 (Grey white)
Inside/Outside paint door RAL 9002 (Grey white)
Layer thickness color 80 μm
Dimensions
Outside
width [meter] 2.505
depth [meter] 3.760
hight [meter] 2.400
Transport hight [meter] 2.500
Inside
width [meter] 2.190
depth [meter] 3.445
hight [meter] 2.100
Treshold high 176
Galvanized sump made of steel with 5mm thickness
Sump volume
volume steel sump [Liter] 1.000
Door
Door EI2 90-C
Door model Double door, DIN right
Door position short side, centrally
Door wide [meter] 2-wing 1.915
Door high [meter] 2-wing 1.955
Loads and weights
Snow-load sk [kN/m²] 2,5
Wind-load q (w,k) [kN/m²] 0,58
Max. load flat grids [kg/m²] 1.000
Council load flat grids [kg/200 x 200 mm] 140
Mesh flat grids [mm] ---
Total weight container [kg] 2.500
Air Cooling System
Air Conditioner Outside/Inside
Room temperature
min. +10 °C (heating) at an external temperature of - 15 °C
max.+15 °C (cooling) at an external temperature of + 35 °C
Connection voltage 400 V, 50 Hz
Air circulation - Room heater
Air cirulation heater, spray water protected, safety class IP 54
Assembled and wired until main connector
Designed to support the heating function of the air conditioning
Heat output 3 kW
Electrical connection 400 V
Built in Lighting
Comfort control (switch cabinet)
For the control of a container with a door latch, lighting and climate control
equipment
Climate control Comfort Control with LCD graphical display
for monitoring and control of the cooling and/or heating function of the hazmat
container with climate control system
Driveway ramp for hand lift trucks
Width ca. 1.000 meter
Depth ca. 1.700 meter
Wheel load 400 kg
Angle of elevation 5 °
CLIN 0002
Delivery & Removal of Existing Container
FFP
Door-to-Door Delivery
STUTTGART ARMY HEALTH CLINIC
2300 BLDG
STUTTGART 70569
CLIN 0003
Electrical Installation
FFP
Electrical onsite Installation shall be provided by the contractor to include all
required materials.
Contractor must ensure all equipment is operational.