Text version
W40M EUR REGIONAL CONTRACT OFC
KIRCHBERG KASERNE
BUILDING 3705
POC NICHOLAS ROWTON
LANDSTUHL 66849
0011004478-0001
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15A. NAME AND TITLE OF SIGNER (Type or print)
30-105-04EXCEPTION TO SF 30
APPROVED BY OIRM 11-84
STANDARD FORM 30 (Rev. 10-83) Prescribed by GSA
FAR (48 CFR) 53.243
The purpose of this amendment is to make the follow ing changes:
i. remove the w ording from CLIN 0002 "Removal of the container ii rew ord technical factor 6 original: MFG w ill provide installation of new container and removal of old container to New : MFG w ill provide installation of new container.
1. CONTRACT ID CODE PAGE OF PAGES
J 1 6
16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)
16C. DATE SIGNED
BY 12-Apr-2017
16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR
(Signature of Contracting Officer)(Signature of person authorized to sign)
8. NAME AND ADDRESS OF CONTRACTOR (No., Street, County, State and Zip Code) X W9114F-17-T-0041
X 9B. DATED (SEE ITEM 11)
29-Mar-2017
10B. DATED (SEE ITEM 13)
9A. AMENDMENT OF SOLICITATION NO.
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer is extended, X is not extended.
Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:
(a) By completing Items 8 and 15, and returning 1 copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;
or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN
REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
12. ACCOUNTING AND APPROPRIATION DATA (If required)
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE
CONTRACT ORDER NO. IN ITEM 10A.
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority)
E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
10A. MOD. OF CONTRACT/ORDER NO.
2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO.(If applicable)
6. ISSUED BY
3. EFFECTIVE DATE
12-Apr-2017
CODE
W40M EUR REGIONAL CONTRACT OFC
KIRCHBERG KASERNE
BUILDING 3705
LANDSTUHL AE 66849
W9114F 7. ADMINISTERED BY (If other than item 6)
4. REQUISITION/PURCHASE REQ. NO.
CODE W9114F
FACILITY CODECODE
EMAIL:TEL:
W9114F-17-T-0041
SECTION SF 30 BLOCK 14 CONTINUATION PAGE
SUMMARY OF CHANGES
SECTION SF 1449 - CONTINUATION SHEET
SUPPLIES OR SERVICES AND PRICES
CLIN 0001
The CLIN extended description has changed from:
Fire-Rated Storage Container (For Outside Storage).Requirements must Include:Frame construction made of sand blasted sections Roof and side walls must be made of fire resistant casing (EI 120) with fire protection for inside and outside.Color Outside paint container RAL 9002 (Grey white) Inside paint container RAL 9002 (Grey white) Inside/Outside paint door RAL 9002 (Grey white) Layer thickness color 80 µm Dimensions Outside width [meter] 2.505 depth [meter] 3.760 hight [meter] 2.400 Transport hight [meter]
2.500 Inside width [meter] 2.190 depth [meter] 3.445 hight [meter] 2.100 Treshold high 176 Galvanized sump made of steel with 5mm thicknessSump volume volume steel sump [Liter] 1.000 Door Door EI2 90-C Door model Double door, DIN right Door position short side, centrally Door wide [meter] 2-wing 1.915 Door high [meter] 2-wing 1.955 Loads and weights Snow-load sk [kN/m²] 2,5 Wind-load q (w,k) [kN/m²] 0,58 Max. load flat grids [kg/m²] 1.000 Council load flat grids [kg/200 x 200 mm] 140 Mesh flat grids [mm] --- Total weight container [kg] 2.500 Air Cooling SystemAir Conditioner Outside/InsideRoom temperature min. +10 °C (heating) at an external temperature of - 15 °C max.+15 °C (cooling) at an external temperature of + 35 °C Connection voltage 400 V, 50 HzAir circulation – Room heaterAir cirulation heater, spray water protected, safety class IP 54Assembled and wired until main connectorDesigned to support the heating function of the air conditioningHeat output 3 kW Electrical connection 400 VBuilt in LightingComfort control (switch cabinet) For the control of a container with a door latch, lighting and climate control equipmentClimate control Comfort Control with LCD graphical displayfor monitoring and control of the cooling and/or heating function of the hazmat container with climate control systemDriveway ramp for hand lift trucksWidth ca. 1.000 meterDepth ca. 1.700 meterWheel load 400 kg Angle of elevation 5 °
To:
Requirements must Include:Frame construction made of sand blasted sections Roof and side walls must be made of fire resistant casing (EI 120) with fire protection for inside and outside.Color Outside paint container RAL 9002 (Grey white) Inside paint container RAL 9002 (Grey white) Inside/Outside paint door RAL 9002 (Grey white) Layer thickness color 80 µm Dimensions Outside width [meter] 2.505 depth [meter] 3.760 hight [meter] 2.400 Transport hight [meter] 2.500 Inside width [meter] 2.190 depth [meter]
3.445 hight [meter] 2.100 Treshold high 176 Galvanized sump made of steel with 5mm thicknessSump volume volume steel sump [Liter] 1.000 Door Door EI2 90-C Door model Double door, DIN right Door position short side, centrally Door wide [meter] 2-wing 1.915 Door high [meter] 2-wing
1.955 Loads and weights Snow-load sk [kN/m²] 2,5 Wind-load q (w,k) [kN/m²] 0,58 Max. load flat grids [kg/m²] 1.000 Council load flat grids [kg/200 x 200 mm] 140 Mesh flat grids [mm] --- Total weight container [kg] 2.500 Air Cooling SystemAir Conditioner Outside/InsideRoom temperature min. +10 °C (heating) at an external temperature of - 15 °C max.+15 °C (cooling) at an external temperature of + 35 °C Connection voltage 400 V, 50 HzAir circulation – Room heaterAir cirulation heater, spray water protected, safety class IP 54Assembled and wired until main connectorDesigned to support the heating function of the air conditioningHeat output 3 kW Electrical connection 400 VBuilt in LightingComfort control (switch cabinet) For the control of a container with a door latch, lighting and climate control equipmentClimate control Comfort Control with LCD graphical displayfor monitoring and control of the cooling and/or heating function of the hazmat container with climate control systemDriveway ramp for hand lift trucksWidth ca. 1.000 meterDepth ca. 1.700 meterWheel load 400 kg Angle of elevation 5 °.
CLIN 0002
The CLIN description has changed from Delivery & Removal of Existing Container to Delivery.
The CLIN extended description has changed from:
Door-to-Door DeliverySTUTTGART ARMY HEALTH CLINIC2300 BLDGSTUTTGART 70569Removal and disposal of existing Container.
To:
Door-to-Door DeliverySTUTTGART ARMY HEALTH CLINIC2300 BLDGSTUTTGART 70569.
The following have been modified:
ADDENDUM TO 52.212-1
The following paragraphs are hereby amended:
Paragraph 52.212-1(a) Does not apply to this Request for Quotation.
Paragraph 52.212-1(b)(4) is hereby replaced with the following:
NOTE: To all Vendors: Please check (X) a box below:
Please identify the method of shipment (see paragraph 52.212-1 (b)(8) below:
AIR SEA GROUND
Technical Factor. The quoter must demonstrate compliance with the requirements in the Request for Quotation by submitting a written quote which addresses compliance with each of the following technical factors:
Evaluation Criteria Standard Standard
Acceptable Unacceptable
Subfactor 1: All Salient Characteristics have to be met
Subfactor 2: The roof and the sidewalls must be made of fire resistant casing, with fire protection for inside and outside
Subfactor 3: Interior flooring must be insulated and have anti slip material that is resistant to non-coloring alcohol-containing disinfectants, household chemicals and dilute acids and alkalis with a short-term effect
Subfactor 4: The container must include built in lighting Subfactor 5: The container must include Combined high efficiency air cooler and heater with CFC free refrigerant
Subfactor 6: MFG will provide installation of new container
Failure to receive an Acceptable rating of any of the above salient characteristics / evaluation criteria will result in an Unacceptable technical rating unless the error(s), deficiency (ies) or omission (s) can be corrected.
Paragraph 52.212-1 (b) (8) Completed representations and certifications, add - See 252.247-7022 Representation of Extent of Transportation by Sea.
Paragraph 52.212-1(c) is hereby replaced with the following:
The quoter agrees to hold the prices in its quotation firm for 60 calendar days from the date specified for receipt of quotations, unless another time period is specified in an addendum to the Request for Quotation.
Paragraph 52.212-1(d) does not apply to this Request for Quotation.
Paragraph 52.212-1(i) does not apply to this Request for Quotation.
Add the following:
Paragraph 52.212-1 (h)(ii) Only one Purchase Order will be awarded from this RFQ. Award will be on an “All OR NONE” basis. Quotes for less than all of the solicited line items will be rejected as nonconforming and unacceptable to the RFQ.
Paragraph 52.212-1(m) Quotes shall describe how your product meets the above salient characteristics and are equal to the items listed in the schedule. Vendors quoting an equal product must submit a written narrative describing how the product is equal to the brand name. If you do mark any block “Unacceptable” please explain why the product you quoted doesn’t meet the Subfactor.
Paragraph 52.212-1(n) ELECTRONIC Quotation. Quoters may submit electronic quotation in response to this Request for Quotation. The quotation must be received by the quotation due date/local time as specified in block 8 of the SF 1449 cover page to the inbox of the following email address: nicholas.j.rowton.civ@mail.mil Vendors may call Mr. Nichols Rowton at 011-49-6371-9464-to verify receipt of the quote. If the vendor chooses to email the quote, the Government will not be responsible for any failure of transmission or receipt of the quote, or any failure of the vendor to verify receipt of the emailed quote.
Paragraph 52.212-1(o) QUESTIONS. Prospective quoters are strongly encouraged to submit any questions regarding this Request for Quotation no later than five business days prior to the request for quote due date specified in block 8 of the SF 1449 cover page. Questions can be emailed to nicholas.j.rowton.civ@mail.mil or fax +49- 6371-86-8070. All questions received will be answered officially through an amendment to the Request for Quotation for distribution to all prospective quoters. Questions received after the local Germany cut-off date/time will not be accepted by the Government.
Paragraph 52.212-1 (p) The non-FAR Part 12 discretionary FAR, DFARS, AFARS, and LOCAL provisions included herein are incorporated into this Request for Quotation either by reference or in full text. If incorporated by reference, see provision 52.252-1 herein for locations where full text can be found.
Paragraph 52.212-1 (q) SITE VISIT. If requested, a site visit must be requested no later than 10 April 2017 and will be coordinated and conducted at the Stuttgart Army Health Clinic, Stuttgart, Germany. Contact Nicholas Rowton via email nicholas.j.rowton.civ@mail.mil or phone 011-49-6371-9464 to coordinate the date and time.
Paragraph 52.212-1(r) If a Quoter believes that the requirements in these instructions contain an error, omission, or are otherwise unsound, the Quoter shall immediately notify the Contracting Officer (KO) in writing with supporting rationale.
ACQUISITION PROCEDURE: This is a commercial item under FAR Part 12 and the acquisition procedures to be used for this purchase will be in accordance with FAR Part 13 Simplified Acquisition Procedures.
SPECIAL NOTE: All vendors must be registered in the System for Award Management (SAM) prior to award, and lack of registration shall make a quotation ineligible for award. Vendors may obtain information on registration and annual confirmation requirements by calling 1-866-606-8220 or via Internet at https://www.sam.gov.
(End of provision)
52.212-2 EVALUATION--COMMERCIAL ITEMS (OCT 2014)
Paragraph (a) is hereby replaced with the following:
(a) Evaluation. Award will be made using the lowest price technically acceptable (LPTA) evaluation process.
Award will be made to the responsible quoter on the basis of the lowest evaluated price of quotes meeting or exceeding the acceptability standards for technical factors. The Government intends to make an award without conducting discussions. After the initial evaluation of quotations is completed, if one or more quotations are rated Acceptable Technical, the initial evaluation will become the final evaluation of quotations and award will be made without discussions to the lowest priced quote. If any one (1) technical subfactor is rated Unacceptable after the initial evaluation, the technical factor will be rated Unacceptable and the quote will no longer be considered for award. If all quotations submitted result in an unacceptable technical evaluation, then clarifications may be necessary. In that event, the Government evaluation team will evaluate the quoter's response to the Government exchanges with each quoter.
Factor 1 - Technical: The vendor shall submit a written quote which explains how to comply with the requirements in the RFQ:
Evaluation Criteria Standard Standard
Acceptable Unacceptable
Subfactor 1: All Salient Characteristics have to be met
Subfactor 2: The roof and the sidewalls must be made of fire resistant casing, with fire protection for inside and outside
Subfactor 3: Interior flooring must be insulated and have anti slip material that is resistant to non-coloring alcohol-containing disinfectants, household chemicals and dilute acids and alkalis with a short-term effect
Subfactor 4: The container must include built in lighting Subfactor 5: The container must include Combined high efficiency air cooler and heater with CFC free refrigerant
Subfactor 6: MFG will provide installation of new container
EVALUATION STANDARDS. The quoter’s technical quote will be evaluated using the following standards for a final rating:
ACCEPTABLE: A quote that meets the Government’s technical requirements identified in the Request for Quotation.
UNACCEPTABLE: A quote that fails to meet the Government’s technical requirements identified in the Request for Quotation.
Factor 2 - Price: The Government will select the quote that is based upon the lowest evaluated price, technically acceptable quote. All Contract Line Item Numbers (CLINS) must be priced by the quoter. If the quoter failed to price all CLINs, the quote will not be considered for award.
(b) A quotation is not an offer and, consequently, cannot be accepted by the Government to form a binding contract. Therefore, issuance by the Government of an order in response to a supplier’s quotation does not establish a contract. The order is an offer by the Government to the supplier to buy certain supplies or services upon specified terms and conditions. A contract is established when the supplier accepts the offer.
(c) The word "quoter" shall be substituted for the word "offeror" wherever it appears in FAR 52.212-3, Alternate I and DFARS 252.212-7000.
(End of provision)
(End of Summary of Changes)