Rapid River Ranger District Tree Cooler Reprocurement

Closed Solicitation Posted

This opportunity was awarded. See the award notice from .

Solicitation number
12569R19B0001
Agency
Region 9 - Eastern Region Forest Service, Department of Agriculture
Responses due
Set-aside
Total Small Business

Opportunity facts

Contract number
12569R19C0003 Federal contract award
NAICS code
236210 Industrial Building Construction
PSC
Not on record
Place of performance
Rapid River Ranger District, United States

Notice details come from SAM.gov. Updated .

Notice text

3 versions

Update #3 · Latest ·

The purpose of FBO amendment dated 12/11/18 is to remind prospective bidders that though Norlake Scientific is indicated as the cooler and refrigeration equipment manufacturer in the Basis of Design, other manufacturer's cooler/refrigeration systems may be proposed as "or equal". To be determined as equal and be approved, other systems must meet the following requirements:

1. Manufactured/designed by a company having 5 or more years' experience providing systems of similar size and complexity.


2. Meets the performance requirements indicated below.


3. Provides similar level of functionality, operability, maintainability and durability to the attributes described below. It is the manufacturer's responsibility to provide adequate documentation to the government to allow the government to make direct comparisons.


4. All variations are fully described and the Contractor assumes all responsibility for changes in the overall design and there are no cost increase to the Government.


5. All redesign changes are provided with the shop drawing submittals.


While not an all-inclusive list, following are potential manufacturers that may offer an acceptable cooler and refrigeration equipment:


1. Bally Insulated Modular Structures, www.ballyrefboxes.com, 1-800-24BALLY.


2. BMIL Technology, http://bmil.com, 252-727-0994


3. American Walk-in Coolers, www.americanwalkincoolers.com/coldstoragewarehouse.html, (800) 430-4468


4. US Cooler, www.uscooler.com/, 217-228-2421


5. Arctic Walk-in Coolers and Freezers, www.arcticwalkins.com/
See attached SF-30 that changes the Bid Opening Date and the location for receipt of sealed bids.

.

Update #2 ·

The purpose of FBO amendment dated 12/11/18 is to remind prospective bidders that though Norlake Scientific is indicated as the cooler and refrigeration equipment manufacturer in the Basis of Design, other manufacturer's cooler/refrigeration systems may be proposed as "or equal". To be determined as equal and be approved, other systems must meet the following requirements:

1. Manufactured/designed by a company having 5 or more years' experience providing systems of similar size and complexity.


2. Meets the performance requirements indicated below.


3. Provides similar level of functionality, operability, maintainability and durability to the attributes described below. It is the manufacturer's responsibility to provide adequate documentation to the government to allow the government to make direct comparisons.


4. All variations are fully described and the Contractor assumes all responsibility for changes in the overall design and there are no cost increase to the Government.


5. All redesign changes are provided with the shop drawing submittals.


While not an all-inclusive list, following are potential manufacturers that may offer an acceptable cooler and refrigeration equipment:


1. Bally Insulated Modular Structures, www.ballyrefboxes.com, 1-800-24BALLY.


2. BMIL Technology, http://bmil.com, 252-727-0994


3. American Walk-in Coolers, www.americanwalkincoolers.com/coldstoragewarehouse.html, (800) 430-4468


4. US Cooler, www.uscooler.com/, 217-228-2421


5. Arctic Walk-in Coolers and Freezers, www.arcticwalkins.com/

.

Update #1 ·

The USDA Forest Service, Lake States Acquisition Team is announcing an opportunity for the construction of the Rapid River Ranger District Tree Cooler Building on the Hiawatha National Forest in the Upper Peninsula of Michigan. THIS IS A REPROCUREMENT OPPORTUNITY.


This work consists of constructing a 2,736 SF (38'x 72') wood Post Frame building with 14 feet high sidewalls and 4:12 roof Pitch. Building will be separated into a heated space of about 760 SF and unheated space of about 1976 SF. Work includes site grading and preparation, extension of natural gas, water and electrical lines to the building, and six reinforced concrete floor. The heated portion of the building will be insulated and an interior partition wall constructed separating the heated portion from the unheated portion. Furnish and install a 1440 SF (30' x 48') Tree cooler within the unheated portion of the Building. The building will be construction on the Rapid River Ranger District Office Administrative Site, located in Rapid River Mi.



In accordance with FAR Part 36.204(b), the estimated magnitude of construction is between $250,000 and $500,000 for the total project. The applicable North American Industry Classification System (NAICS) Code is 236210. The Small Business Administration size standard is $36.5 million. Contractors are required to be actively registered with the System for Award Management (SAM).



This is a combined synopsis/solicitation. No hard copies of the solicitation, supporting documents and applicable amendments, if any, will be provided. To receive the entire solicitation package and any applicable amendments, prospective offerors must download them from the FedBizOpps website. The contractor shall provide all management and project administration services, quality control, logistical support, vehicles, labor, equipment and materials to complete the work described in the solicitation.



Bacon-Davis wage rates apply to this project and are included as an attachment.



All invoices must be submitted via the electronic Invoice Processing Platform (IPP). This is a mandatory requirement initiated by the U.S. Department of Treasury. For more information see website https://www.ipp.gov/index.htm. Please make sure that your company has registered for an account at https://www.ipp.gov/vendors/enrollment-vendors.htm.



Contracting Officers Representative for this contract and for technical questions is: Adam Garrison, 906-428-5843 or agarrison@fs.fed.us.

.

Attachments

Files attached to this notice, newest first
File Type Posted
amend4_sf_30.pdf PDF
amend3_sf_30.pdf PDF
amend2_sf_30.pdf PDF
amend1_sf_30.doc DOC document
att1_stamped_truss_submittal.pdf PDF
Att2_post_depth.docx DOCX document
att3_wage_rate.pdf PDF
att1_FinalSpecPackage(03.12.18).pdf PDF
att4_Material_Inventory.pdf PDF
att2_RRRD_Tree_Cooler_Pole_Barn_Final_Submission_03-19-18.pdf PDF
cooler_solicitation.pdf PDF
Show all 11

Notice history

Notices posted for this opportunity, newest first
Notice Type Posted
Rapid River Ranger District Tree Cooler Reprocurement Award Award Notice
Rapid River Ranger District Tree Cooler Reprocurement This notice · Latest solicitation Solicitation

On GovTribe

Work this opportunity on GovTribe

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity