Rapid Response Requirement for a 50kw propane-fueled generator set
Closed Pre-Solicitation Posted
- Solicitation number
- W912HN25C00SM
- Agency
-
ENDIST Savannah
US Army Corps of Engineers, Department of Defense
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 335312 Motor and Generator Manufacturing
- Place of performance
- Augusta, Georgia, United States
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of the Army Corps of Engineers Engineering District Savannah is seeking information on vendors who can replace an existing 50kW diesel generator, fuel tank, and automatic transfer switch (ATS) at the Lock Operations Building in Savannah, Georgia. The contractor shall demolish and remove the existing equipment, and install a new 50kW propane-fueled generator set, propane fuel tank, and ATS on a new elevated equipment pad adjacent to the existing service transformer. The agency has provided a draft Statement of Work detailing the requirements for this work. Interested vendors are asked to respond with information on their capabilities and delivery timelines by October 4, 2024.
This is an unrestricted requirement, with no set-aside designations. The agency has not identified any potential incumbents or provided any details on the anticipated award value or budget. The key numerical details include the 50kW generator capacity and the requirement to replace the existing diesel-powered equipment with a new propane-fueled system.
Notice text
We would like to know who can perform this work and how soon we can have delivery, removal and installation.
See attached DRAFT Statement of Work for Request for Information (RFI) Purposes ONLY.
The Contractor shall replace the existing 50 kW diesel generator, diesel fuel tank and automatic transfer switch (ATS) with a new generator, new fuel tank and ATS. The existing generator set, fuel tank and ATS located in the Lock Operations Building shall be demolished, removed and disposed of by the Contractor. The existing diesel fuel tank is located on the first floor of the Lock Operations Building behind a chain-link fence.The existing generator set and ATS are located on the second level of the Lock Operations Building. A new propane-fueled generator set, propane fuel tank and ATS shall be provided and installed on the land-side pavilion between the Lock Operations Building and the public parking area. The new generator, fuel tank and ATS shall be located on a new elevated equipment pad constructed adjacent to the existing service transformer.
Files
| File | Type | Posted |
|---|---|---|
| Cable Tower.JPG | JPG image | |
| Diesel Pump.JPG | JPG image | |
| Dam Diesel Fuel Storage Tank.JPG | JPG image | |
| Diesel Generator.JPG | JPG image | |
| Draft Statement of Work.pdf |