Q301--SPS Water Testing Services for Clement J. Zablocki VA Medical Center located in Milwaukee, WI.
Closed Solicitation Posted
- Solicitation number
- 36C25225Q0421
- Agency
-
Veterans Integrated Service Network 12
Veterans Health Administration, Department of Veterans Affairs
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 541380 Testing Laboratories and Services
- PSC
- Q301 Reference Laboratory Testing
- Points of contact
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 12 is seeking water testing services for the Clement J. Zablocki VA Medical Center located in Milwaukee, Wisconsin. The solicitation (36C25225Q0421) requires quarterly water and steam sample testing in compliance with AAMI ST108-2023 standards, specifically involving collection and analysis of 26 total samples from various medical device reprocessing connection points. Contractors must perform testing between 7:00 AM and 4:00 PM Monday through Friday, excluding federal holidays, with requirements including bacteria testing, endotoxin testing, and field tests for pH, conductivity, hardness, and alkalinity. The solicitation's final offer submission deadline is June 6, 2025, at 10:00 AM CDT, with vendor questions accepted until June 4, 2025. Contractors must follow strict sampling protocols, including 60-second source flushing, port disinfection, and use of provided personal protective equipment.
The contract is not set aside for any specific business size or designation, making it open to all qualified vendors. The procurement follows Brown County Wage Determination 2015-4893 Rev-26, with a contract structure including one base year and four potential one-year option periods. While specific award value is not explicitly stated, the solicitation falls under NAICS category 541380 for Testing Laboratories and Services with a size standard of $19 million. The place of performance is the Clement J. Zablocki VA Medical Center at 2851 University Avenue in Milwaukee, Wisconsin. Contractors will be responsible for providing sample containers, collecting samples, reporting results, and implementing follow-up testing if results exceed acceptable limits per the AAMI standard. The testing will cover critical water sources used in medical device reprocessing, including reprocessing sinks, ultrasonic cleaners, instrument washers, cart washers, and automated endoscope reprocessors.
Notice text
4 versions
Update #4 · Latest ·
Amendment to date to answer vendor questions and to receive offers.
Update #3 ·
Vendor Questions/Answers
How many of the 26 samples need endotoxin testing? 3 at AER s require Endotoxin
Per Table 2, 4, 5, and 6 no Endotoxin testing on Utility water is required? See answer to question 1. There are special circumstances for those areas.
How many of the 26 samples need pH, Alkalinity, Hardness, and Conductivity? Follow tables 5 and 6. (4, 2 hot and 2 cold)
Will any Ionic contaminant testing be needed following table 2 of the standard? Yes.
Will this RFP request sampling at the Water Generation systems outlined in Table 5? This is considered where the city water enters the building and where hot water exits the hot water heaters.
Will field tests for pH, Conductivity, Hardness, and Alkalinity be permitted per table 5 and 6 or will this need to be tested at a lab? Field tests are fine.
There is not an indication for the number of retests that can be expected per quarter. Can the government provide historical information regarding retests for the past 3 years? This is a completely new process. I have no data to determine the potential number of retests.
Will the government issue a PO for retests or should retests be included in the YR CLIN? Retests should be included in the YR CLIN.
If one parameter is out of specification and requires a retest, does the government intend to retest the whole panel, or solely the parameter that was out of specification? We would require only the retest for the one problem and not the entire panel.
Should the government request a retest of only those parameters that are out of specification, would the government consider splitting the CLIN table into each parameter quantity per year for routine and retests? No.
The table provided on page 8 indicates utility water is not tested for endotoxin, however, in the Scope of Work it is stated that The contractor shall provide colony count and endotoxin results by phone if above the Alert Limit. Can the government please confirm that endotoxin will be tested for all sources except the steam condensate? See answers to questions 1 and 2, above. Bacteria needs to be tested at all 26 points. Only 3 samples will require endotoxin testing.
Can the government provide photos of the equipment to be tested and the ports available to pull from for those who were not able to attend the site visit? Photos can be provided upon request.
Is the contractor responsible for providing the contractor personnel with appropriate PPE? Basic PPE Provided.
Can the government provide a list of the appropriate PPE required for this SPS facility? Basic PPE will be provided. (Full body coverall, shoe covers, mask, eye shields, gloves, hair bonnet.)
Are all the sources within a single location within the SPS facility? 25 locations are In one connected area, Steam collector is in a separate room on the same floor.
Will the contractor personnel be required to make multiple PPE changes during the collection event? No.
Does the government require each SPS source to be flushed before collection? Yes. Per AAMI recommendation, each source should be flushed for at least 60 seconds prior to sampling.
Does the government require the port from each source to be disinfected with an alcohol swab prior to collection? Yes. All ports that require bacteria sampling do require an alcohol swab.
If the source port is to be swabbed, will the government provide the alcohol swabs? Yes. This can be provided.
The RFQ mentions endotoxin sampling, but it only lists Utility and Steam sample locations. ST108 does not require Endotoxin sampling unless it is on a Critical Water source. Please advise. See answer to questions 1 and 2. Due to the potential for sub micron-filtered utility water to be the final rinse, we are testing for endotoxins at 3 points.
Does this VA have any critical water systems/POUs that will require sampling? No. (It is already being done.)
Is this VA utilizing Utility Water for Critical applications, and they need endotoxin samples to be taken at each Utility POU? We are proceeding with great caution because there is a gray area with scope processors. We are sampling endotoxins at 3 points. See answers for questions 1 and 2.
There is a slight discrepancy in what the project is asking for and what ANSI AAMI ST108 is asking for. We would appreciate confirmation on the following to ensure full compliance with ANSI/AAMI ST108 and appropriate service alignment:
Question 1:Â Â That no critical water systems or point-of-use filtration/treatment fixtures are part of the testing scope; Correct.
Question 2:Â That there is no requirement for full annual validation testing beyond the outlined quarterly testing; Correct.
Question 3: That only one steam condensate sample is required per quarter;Â Correct
Question 4:Â That 25 utility water point-of-use samples are to be tested quarterly, and whether endotoxin testing is explicitly required for each utility water site (as this exceeds ST108 s standard quarterly testing parameters). Reduce this to 3 points for endotoxin testing.
Since ST108 does not mandate endotoxin testing for utility water on a quarterly basis, I want to confirm that the inclusion of endotoxin analysis at utility POUs is an intentional facility-specific requirement. Reduce to 3 points for endotoxin testing.
Water Quality Monitoring Bacteria and Endotoxins:
The scope mentions testing for bacteria and endotoxin(s) in relation to water quality monitoring. Could you please specify which particular bacterial, and endotoxins are required for testing? This will help us ensure the appropriate analytical methods and accredited laboratories are utilized. Please refer to ST108. It would be all of them.
Protective Equipment for Sterile Processing Areas:
The document references the use of protective equipment for entering sterile processing areas. Could you confirm the specific PPE required for access to these areas? Additionally, should we anticipate providing all PPE for our personnel, or will any of this be furnished by the facility? Basic PPE will be provided. (Full body coverall, shoe covers, mask, eye shields, gloves, hair bonnet.)
Is there any incumbent/recompete or this is a brand-new project? If yes, could you please provide us with their award number or even if the customer bought similar services in the past. No. This is a new process.
What is the Place of Performance?
The Place of Performance shall be Milo C. Huempfner Green Bay HCC located in Green Bay, WI.
Update #2 ·
Services under Solicitation 36C25225Q0421 for SPS Water Testing Services shall be performed at Milo C. Huempfner Green Bay HCC located at 2851 University Ave. in Green Bay, WI.
The Wage Determination used shall be Brown County WD 2015-4893 Rev-26 dated 12.23.2024.
All offer shall be due 05/30/2025 @ 10:00am Local Time.
Update #1 ·
System updates may lag policy updates. The System for Award Management (SAM) may continue to require entities to complete representations based on provisions that are not included in agency solicitations. Examples include 52.222-25, Affirmative Action Compliance, and paragraph (d) of 52.212-3, Offeror Representations and Certifications Commercial Products and Commercial Services. Contracting officers will not consider these representations when making award decisions or enforce requirements. Entities are not required to, nor are they able to, update their entity registration to remove these representations in SAM.
Files
| File | Type | Posted |
|---|---|---|
| 36C25225Q0421 0003.docx | DOCX document | |
| 36C25225Q0421 0004.docx | DOCX document | |
| 36C25225Q0421 0002.docx | DOCX document | |
| FBO DESCRIPTION-2.docx | DOCX document | |
| P07 - Brown County WD 2015-4893 Rev-26 dated 12.23.2024.pdf | ||
| S02-36C25225Q0421_1 02.docx | DOCX document | |
| 36C25225Q0421 0001.docx | DOCX document | |
| 36C25225Q0421_1.docx | DOCX document | |
| P07 - Milwaukee County WD 2015-4899 Rev-26 dated 12.23.2024.pdf |
Notice history
| Notice | Type | Posted |
|---|---|---|
| This notice | Solicitation | |
| Q301--SPS Water Testing Services for Clement J. Zablocki VA Medical Center located in Milwaukee, WI. | Pre-Solicitation | |
| Q301--SPS Water Testing Services for Milo C. Huempfner Green Bay VA Health Care Center located in Green Bay, WI. | Pre-Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| B533--VANIHCS SPS Water Testing (VA-27-00000760) | Veterans Integrated Service Network 10 | Service-Disabled Veteran-Owned Small Business | |
| B533--VANIHCS SPS Water Testing (VA-27-00000760) | Veterans Integrated Service Network 10 | Service-Disabled Veteran-Owned Small Business | |
| F109--Water Management Program and Chemical Testing Amendment 001- Q&A | Veterans Integrated Service Network 1 | Service-Disabled Veteran-Owned Small Business | |
| F103--D and D laboratory steam & water testing | Veterans Integrated Service Network 6 | No set-aside | |
| Effluent Wastewater Testing - Saginaw VAMC | Veterans Integrated Service Network 10 | Service-Disabled Veteran-Owned Small Business |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity