Provide semi-annual preventive maintenance inspections and services and annual load bank testing on emergency generators
Award Notice Posted
- Solicitation number
- VA26315Q0550
- Agency
-
Veterans Integrated Service Network 23
Veterans Health Administration, Department of Veterans Affairs
- Awarded
- to Electrical Engineering And Equipment Company
- Set-aside
- No set-aside
Opportunity facts
- Contract number
- VA263-15-C-0080 Federal contract award
- NAICS code
- 335311 Power, Distribution, and Specialty Transformer Manufacturing
- PSC
- Not on record
Notice details come from SAM.gov. Updated .
Notice text
2 versions
Update #2 · Latest ·
Annual Service Maintenance Emergency Generators BHHCS
Contract issued 04/29/2015
BHHCS VA Medical Center, Fort Meade, SD 57741
VA263-15-C-0080
Update #1 ·
Statement of Work
Annual Service Maintenance Emergency Generators BHHCS
1. Provide semi-annual preventive maintenance inspections and services on emergency generators at the VA medical Centers at Ft Meade and Hot Springs, South Dakota. Inspection reports from attachments A & B to be provide to facilities POC's.
2. Contract POC's for scheduling work and coordination are as follows:
Fort Meade VAMC: Tom Smith, Operations Supervisor, Phone: 605-720-7134
Hot Springs VAMC: Dan Cerveny, Maintenance Supervisor, Phone 605-745-2268
3. Fort Meade Emergency Generator equipment included in the scope of work is as follows:
A. Bldg. 113 Emergency Generator - Manufacturer: John Deere / KatoLight / 350 KW
Generator Model; 433PSL6216 / Serial Number: WA-547830-1205
Engine Model: D350FPJ4 / Serial Number: 119198-0106
B. Bldg. 148 Emergency Generator - Manufacturer: Cummins / Onan / 125 KW
Generator Model: DSGAB- 1321187 / Serial Number: B130456361
Engine Model: QSB7 - G5 NR3 / Serial Number: 73494119
C. Bldg. 145 Emergency Generator - Manufacturer: Caterpillar / KatoLight / 230 KW
Generator Model: SR4B / Serial Number: 6YR02788
Engine Model: 3306 / Serial Number: 9NR05844
D. Bldg. 137 Emergency Generator - Manufacturer: Cummins / Onan / 100 KW
Generator Model: DSGAA- 1321189 / Serial Number: B130456362
Engine Model: QSB7 - G5 NR3 / Serial Number: 73493506
E. Bldg. 160 Emergency Generator - Manufacturer: Cummins /Onan / 165 KW
Generator Model: UC1274H / Serial Number: F940545538
F. Bldg. 155 Main Station Generator - Manufacturer: Detroit / KatoLight / 2000KW
Generator Model: 744SFM4988 / Serial Number: WA567823-0908
Engine Model: CD2000SX6T2 / Serial Number: 79811-1-1-1208
G. Bldg. T296 Fire Station Emergency Generator - Manufacturer: Cummins / Onan / 49HP Generator Model; DSKCA-193329 / Serial Number: L090070761
3. Hot Springs VAMC Emergency Generator equipment included in the scope of work is as follows:
A. Bldg. 10 Emergency Generator - Manufacturer: Generac
Generator Model: 98A03219-S/ Serial Number: 2042251
Engine Model: 92460 / Serial Number: G3407-2
B. Bldg. 12 Emergency Generator - Manufacturer: Generac
Generator Model: 433RSL4021/ Serial Number: LM-239579-0701
Engine Model: OA8829/ Serial Number: 8DC9-446846
C. Bldg. 18 Emergency Generator - Manufacturer: Onan
Generator Model: 230DFAB / Serial Number: A980673745
Engine Model: LTA10-G1 / Serial Number: 12079
D. Mobile MRI Emergency Generator - Manufacturer: John Deere
Generator Model: 4045hf285H,I,J / Serial Number: PE4045L250238
E. Mobile CT Emergency Generator - Manufacturer: John Deere
Generator Model: 4045
4. Semi-annual Inspections will be completed in August/September and March/April and inspection reports are to be provided to the VAMC POC's within 30 days of completion of work. Work shall be scheduled 7 days in advance of planned work to minimize disruption to the facility.
5. The Scope of August/September inspections and testing will include all work outlined in Attachment A. The scope of March/April Inspections will include all work outlined in Attachment B.
6. Annual Load Bank Testing included in Attachment A will be accomplished in accordance with NFPA 110 (99) Sec 6-4.2.2. The testing shall be documented and supplemental loads included at 25% of the name plate rating for 30 minutes followed by 50 percent of the nameplate rating for 30 minutes, followed by 75 percent
All emergency generators will be load bank tested with exception of the following generators:
Fort Meade: Bldg. 155 Main Station Generator, Bldg. T296 Fire Station Emergency Generator
Hot Springs: Mobile MRI Emergency Generator, Mobile CT Emergency Generator