PN 92594 SOF Operations Support Facility

Closed Pre-Solicitation Posted

This opportunity was awarded. See its 2 award notices in the notice history.

Solicitation number
W912PM19R0021
Agency
ENDIST Wilmington US Army Corps of Engineers, Department of Defense
Responses due
Set-aside
No set-aside

Opportunity facts

NAICS code
236220 Commercial and Institutional Building Construction
PSC
Y1JZ Construction Of Miscellaneous Buildings
Place of performance
Fort Bragg, North Carolina 28310, United States

Notice details come from SAM.gov. Updated .

About this opportunity

The U.S. Army Corps of Engineers, Wilmington District is seeking information from contractors capable of constructing a 36,000 square foot Special Operations Forces Operations Support Facility at Fort Bragg, North Carolina, to sensitive compartmented information standards. The facility is required to include command, life support, office, training, medical, and support spaces. Interested firms must submit by May 27, 2019 details on their business size, bonding capacity, and past experience with at least three projects over $17.5 million and three projects over 21,500 square feet, including two sensitive compartmented information facilities. Responses will be evaluated based on the contractor's experience and capabilities. The estimated value of construction is between $25 million to $100 million.

There is no set-aside designation for this pre-solicitation notice. The primary NAICS code is 236220 and PSC code is S206. The facility is required to be constructed within 40 years to Unified Facilities Criteria standards. Interested firms must have a DUNS and SAM registration and be able to complete the project within a one to two year performance period. Details on teaming agreements or joint ventures must demonstrate how roles and labor will be allocated according to small business requirements.

Notice text

2 versions

Update #2 · Latest ·

This Request for Proposal (RFP) solicits construction and design of an Operations Support Facility, at Fort Bragg NC. The scope of work includes the construction of an approximately 36,000 SF Operations Support Facility built to sensitive compartmented information (SCI) standards. Project includes a command section with VTC conference room; life support area with gear storage room, covered loading dock, equipment room, training room, service area, and armory; private and open office areas; planning and training area; language training area with one-roof lab; security office; medical area with offices, exam room, and drug storage area; operations center with private offices; auditorium; heritage/break room; male and female latrines with showers and lockers; janitor closets; electrical room; mechanical room; and communication server rooms. Project includes information systems, fire detection, alarm, and suppression systems, and Energy Monitoring Control Systems (EMCS) connection. Sustainability and energy enhancement measures are included. Project includes information systems, mass notification system, cyber security, and fire protection, detection, and alarm systems. Provide elevator; uninterruptable power source for critical areas; emergency standby power for the entire facility; raised floor system; redundant chiller for the server room; intrusion detection system and closed circuit television installation; cypher locks; and sound attenuation around the command suite and command suite conference room. Supporting facilities include utility services and connection (electrical, water, sanitary sewer, and natural gas); security lighting; GOV parking; POV parking; service drives; walks, curbs and gutters; storm drainage to include outfall relocation; information systems, to include fiber optic cable service and relocation of communications duck bank; lightning protection systems; landscaping; signage; and site improvements. Heating and air conditioning will be provided by self-contained system. Comprehensive building and furnishings related interior design services are required. Access for individuals with disabilities will be provided. Antiterrorism/Force protection measures and sustainment mandates will be incorporated.

The period of performance shall not exceed 540 calendar days. Work location is Fort Bragg, North Carolina. The resultant contract will be Firm-Fixed Price (FFP).

Update #1 ·

SOURCES SOUGHT NOTICE
W912PM19R0021
PN92594, SOF Operations Support Facility, Fort Bragg, NC


This is a Sources Sought/Request for Information only. This is NOT a Solicitation Announcement, nor is it a
Request for Proposal. This request does not obligate the Government in any contract award.

The U.S. Army Corps of Engineers, Wilmington District, is conducting research to determine the market capabilities of potential contractors to construct a 36,000 SF. Operations Support Facility built to sensitive compartmented information (SCI) standards. Project includes command section with VTC conference room; life support area with gear storage room, covered loading dock, equipment room, training room, service area, and armory;, private and open office areas planning and training area; language training area with one-roof lab; security office; medical area with offices, exam room, and drug storage area; operations center with private offices; auditorium; heritage/break room; male and female latrines with showers and lockers; janitor closets; electrical room; mechanical room; and communication/server rooms. Project includes information systems, fire detection, alarm, and suppression systems, and Energy Monitoring Control Systems (EMCS) connection. Sustainability and energy enhancement measures are included. Project includes information systems, mass notification system, Cyber security, and fire protection, detection, and alarm systems. Provide elevator; uninterruptable power source for critical areas; emergency standby power for the entire facility; raised floor system; redundant chiller for the server room; intrusion detection system and closed circuit television installation; cypher locks; and sound attenuation around the command suite and command suite conference room. Supporting facilities include utility services and connection (electrical, water, sanitary sewer, and natural gas); security lighting; GOV parking; POV parking; service drives; walks, curbs and gutters; storm drainage to include outfall relocation; information systems, to include fiber optic cable service and relocation of communications duck bank; lightning protection systems; landscaping; signage; and site improvements. Heating and air conditioning will be provided by self contained system. Measures in accordance with the Department of Defense Minimum Antiterrorism for Buildings standards will be provided. Heating and air conditioning will be provided by self-contained system. Comprehensive building and furnishings related interior design services are required. Access for individuals with disabilities will be provided.

Sustainability/Energy measures will be provided. Facilities will be designed to a minimum life of 40 years in accordance with DoD's Unified Facilities Criteria (UFC1-200-02) including energy efficiencies, building envelope and integrated building systems performance.

The magnitude of construction for this project will be between $25,000,000.00 and $100,000,000.00.

All interested firms with 236220 as an approved NAICs code have until 27 May 2019 at 2:00 p.m. to submit the following information:

- Name & Address of your Firm

- Point of Contact (Name/Phone/E-mail)

- Current SAM

- Business Size, to include designation as HUBZone, 8(a), Service Disabled Veteran Owned Small Business, Small Disadvantaged Business, Woman-Owned Business, and Large Business. Any supporting documentation that confirms your socio-economic status should be provided, e.g., letter of certification from VA confirming SDVOSB status. The Government must be able to verify SBA certification of HubZone and 8(a) via SAM.

- Bonding capability - both single and aggregate capacity contracts or for multiple task orders, as evidenced by submission of Surety Company Letter stating your firms bonding capability.

- Evidence of past experience to include renovation or construction of similar requirements not more than six (6) years old (i.e., complex construction projects, including secure area construction (e.g. military installation)) in the area of Building Construction on:

1) Three (3) projects equal to or greater than $17,500,000.00 in value.
2) Three (3) projects equal to or greater than 21,500 SF in size.
3) At least two (2) of the projects must include the construction of a Sensitive Compartment Information Facility (SCIF) area.

All project examples submitted must be as the prime contractor, Joint Venture or Mentor Protégé. Include the project name and description of the key/salient features of the project (i.e., square footage, multi-story, phased renovation, etc.), completion date, total contract construction value, whether it was Design-Build, Construction only, Renovation or Rehabilitation, etc. Additionally, if you were teaming with another firm, clearly identify your role on the project(s) submitted. Please provide at least one point of contact (with e-mail address and phone number) for project validation. The Government will not give credit to projects if the lack of information hinders the ability to determine relevancy and/or level or experience.

Information on Teaming Arrangement (if applicable). Although we are not looking for formal signed agreements at this time, if you intend to "team" with another firm, formally or informally, you must submit information, not more than one (1) page, about your team's involvement. More specifically, you must submit sufficient information for the Government to determine the roles each team member will play and what your socio-economic status is or will be considering the proposed arrangement. Therefore, included in your one (1) page if you are a Small Business and you intend to mentor/protégé and/or JV with a large business both team members must sign agreeing that 40% of the labor will be performed by the protégé firm. Additionally, if the team is a mentor/protégé arrangement, identify the areas that will be mentored. If the offeror is a Joint Venture (J-V), relevant project experience should be submitted for projects completed by the Joint Venture entity, or the individual firms that make up the joint venture. Offerors that are part of the DoD Mentor Protégé program may submit two (2) recent and relevant projects completed by the Mentor with the remaining project being submitted on behalf of the protégé. Any supporting documentation that confirms your socio-economic status as a team should be provided.

The Government may not give credit to your socio-economic class if there is not sufficient documentation to support it or if the Government cannot verify through other means that your business is as such.

The requested information shall be submitted electronically to:

U.S. Army Corps of Engineers
Attn: John Hill
E-mail: john.t.hill@usace.army.mil

And

Michael Mullen
E-mail: michael.m.mullen@usace.army.mil


The email should be entitled: PN92594, SOF Operations Support Facility, Fort Bragg, NC, Sources Sought

Do not send hard copies of advertising or promotional materials. Please ensure that all responses are comprehensive and provide a name and point-of-contact for your firm for follow-up by this office or the procuring contracting officer. If you have responded to any previous e-mail messages or had other communications with our office regarding preliminary market research for this project, please be advised that it will be necessary for you to respond to this e-mail and the questions contained therein. Any responses involving teaming agreements should delineate between the work that will be accomplished by the Prime Contractor and work accomplished by the teaming partner

All information is to be provided on a voluntary basis at no charge to the Government. There is no entitlement to payment of direct or indirect costs related to or arising out of responding to this request for information. All information provided becomes property of the Government. There is no guarantee, expressed or implied, that the market research for this acquisition will result in any guarantee of award or acquisition strategy.

Attachments

Files attached to this notice, newest first
File Type Posted
PN 92594_RTA SPECS_VOL 01 (1).pdf PDF
PN92594_RTA_PLANS_vol2of2 (1).pdf PDF
NAVFAC_USACE PPQ.pdf PDF
PN 92594_RTA SPECS_VOL 03 (1).pdf PDF
PN92594_RTA_PLANS_vol1of2 (1).pdf PDF
PN 92594_RTA SPECS_VOL 02 (1).pdf PDF
PN 92594_RTA SPECS_VOL 05 (1).pdf PDF
PN92594_W912PM19R0021_SOF Operations Support Facility.pdf PDF
PN 92594_RTA SPECS_VOL 04 (1).pdf PDF

Notice history

Notices posted for this opportunity, newest first
Notice Type Posted
Eagle Island Confined Disposal Facility Improvements for Cell 1, (FY20), Brunswick County, North Carolina Latest Award Notice
PN 92594 SOF Operations Support Facility Award Notice
PN SF-00012-17, Renovate Physical Therapy Area Latest pre-solicitation Pre-Solicitation
PN 92594 SOF Operations Support Facility Solicitation
PN 92594 SOF Operations Support Facility This notice · Original Pre-Solicitation

On GovTribe

Work this opportunity on GovTribe

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity