Plate Reader

Closed Solicitation Posted

Solicitation number
W911S226U3818
Agency
Responses due
Set-aside
Total Small Business

Opportunity facts

Place of performance
Building 753 Cullum Road, West Point NY, 10996 10996

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of the Army Materiel Command Mission and Installation Contracting Command Fort Drum seeks a plate reader instrument capable of acquiring real-time data across multiple measurement modes, with proposals due August 6. This procurement is set aside for Total Small Business.

Place of performance is 753 Cullum Road, West Point, New York. The instrument must integrate monochromator-based fluorescence, UV/Vis absorbance, and luminescence measurement capabilities. Technical requirements include a linear variable monochromator with tunable bandpasses up to 100 nanometers; a tunable dichroic mirror permitting air-based light paths without light guides or fiberoptics; auto-ranging detector sensitivity and gain for fluorescence measurements below 760,000,000 counts with enhanced dynamic range autoranging in less than 0.1 seconds; absorbance measurement via dedicated spectrometer (not monochromator) with complete UV/Vis spectrum from 220 to 1,000 nanometers at 1 nanometer resolution in less than 0.5 seconds using simultaneous diode-array wavelength capture; heated optical head maintaining uniform temperature for incubated microplate wells during detection; temperature control up to 45 degrees Celsius with bottom-reading capability; two automated reagent injectors for kinetic event and flash luminescence initiation; and atmospheric control unit with software-controlled CO₂ and O₂ concentrations at 5% CO₂ for cell culture. The instrument must include software for data visualization and analysis. NAICS code is 334516 (Analytical Laboratory Instrument Manufacturing); PSC is 6630 (Chemical Analysis Instruments).

Notice text

2 versions

Update #2 · Latest ·

Amended to include set aside code. We require an instrument that can acquire real-time data from multiple modes of measurement, including monochromator-based fluorescence, UV/Vis absorbance, and luminescence. We require the following: linear Variable Monochromator, permitting tunable band passes up to 100nm; a tunable dichroic mirror permitting air-based light path for monochromator without light guides or fiberoptics; auto ranging of detector sensitivity and gain for fluorescence measurements below 760,000,000-counts; enhanced Dynamic Range autoranging of detector sensitivity in less than 0.1s; absorbance based on a dedicated spectrometer, not a monochromator. Complete UV/Vis absorbance spectrum from 220nm-1000nm at 1nm resolution in less than 0.5s with all wavelengths captured simultaneously with a diode array; heated optics. A heated optical head means that incubated microplate wells remain in a uniform temperature environment even during detection. The instrument should have a temperature controller than can go up to 45 C, bottom reading, two reagent injectors for automated injection for initiating kinetic events and flash luminescence, and an atmospheric control unit with software-controlled CO2 andO2 concentrations for cell culture at 5% CO2. The unit should come with software for data visualization and analysis.

Update #1 ·

We require an instrument that can acquire real-time data from multiple modes of measurement, including monochromator-based fluorescence, UV/Vis absorbance, and luminescence. We require the following: linear Variable Monochromator, permitting tunable band passes up to 100nm; a tunable dichroic mirror permitting air-based light path for monochromator without light guides or fiberoptics; auto ranging of detector sensitivity and gain for fluorescence measurements below 760,000,000-counts; enhanced Dynamic Range autoranging of detector sensitivity in less than 0.1s; absorbance based on a dedicated spectrometer, not a monochromator. Complete UV/Vis absorbance spectrum from 220nm-1000nm at 1nm resolution in less than 0.5s with all wavelengths captured simultaneously with a diode array; heated optics. A heated optical head means that incubated microplate wells remain in a uniform temperature environment even during detection. The instrument should have a temperature controller than can go up to 45 C, bottom reading, two reagent injectors for automated injection for initiating kinetic events and flash luminescence, and an atmospheric control unit with software-controlled CO2 andO2 concentrations for cell culture at 5% CO2. The unit should come with software for data visualization and analysis.

Similar open opportunities

Opportunity Agency Set-aside Responses due
Aluminum alloy sheet Rock Island, Illinois 61299 · NAICS 331315 MICC Fort Drum Total Small Business
Ballistic Glass Panels Fort Leavenworth, KS 66027 · NAICS 332999 MICC Fort Drum Total Small Business
Industrial Sewing Machines 687 Rogers Place | West Point NY 10996 10996 · NAICS 333248 MICC Fort Drum Total Small Business

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity